GQL Statement
estimated_peak_demand_factor = 0.0004392;
estimated_peak_demand_factor *
SUM(
V(
households_space_heater_district_heating_ht_steam_hot_water,
households_water_heater_district_heating_ht_steam_hot_water,
buildings_space_heater_district_heating_ht_steam_hot_water,
"input_of_steam_hot_water / MJ_PER_MWH"
)
)
Result
2019
0.18
ms
|
2,721.2206378070796
|
MW |
2050
0.07
ms
|
2,693.711970463786
|
MW |
Description
For the present and if time-resolved calculations are turned off
the hourly input curves are not available. In that case
we estimate peak demand by multiplying total demand (in MWh)
by a 'peak demand factor'. This factor is based on NL2015 dataset by
dividing the future demand peak in a blank scenario by the total demand
Characteristics
Groups |
|
Unit |
MW |
File path |
/app/tmp/etsource/gqueries/general/costs/heat_infrastructure/ht/general_support_queries/demand_peaks/households_buildings_district_heating_ht_demand_peak_estimate.gql
|
References