Present 48.18 B 48.18 B 48.18 B
Future 48.18 B 48.18 B 48.18 B
Edges 48.18 B Outputs
Node MJ Type
buildings_local_production_electricity 8.19 B Share
Reversed
17.0 %
83.0 %
Inputs Edges 48.18 B
100.0 %
Type MJ Node
Share 48.18 B environment_sun_solar_radiation
Edges 48.18 B Outputs
Node MJ Type
buildings_local_production_electricity 8.19 B Share
Reversed
17.0 %
83.0 %
Inputs Edges 48.18 B
100.0 %
Type MJ Node
Share 48.18 B environment_sun_solar_radiation

Details

Sector buildings
Use energetic
Merit Order
group
dynamic: solar_pv_on_roof_buildings
level
lv
subtype
volatile
type
producer
Node groups
  1. electricity_production
  2. primary_energy_demand
  3. sustainable_production
  4. volatile_production
  5. lv_net_supply
  6. wacc_proven_tech
  7. costs_building_and_installations_buildings
  8. preset_demand
Used in Gqueries
  1. buildings_potential_electricity_production_of_solar_roof_pv
  2. buildings_solar_pv_curtailed_electricity_output_curve
  3. buildings_solar_pv_electricity_output_curve
  4. buildings_solar_pv_installed_capacity
  5. buildings_solar_pv_production_after_curtailment
  6. buildings_solar_pv_production_before_curtailment
  7. buildings_solar_pv_solar_radiation
  8. buildings_solar_pv_solar_radiation_capacity_in_power_plant_economic_performance_table
  9. buildings_solar_pv_solar_radiation_capex_in_power_plant_economic_performance_table
  10. buildings_solar_pv_solar_radiation_delta_in_investment_cost_table
  11. buildings_solar_pv_solar_radiation_full_load_hours_in_power_plant_economic_performance_table
  12. buildings_solar_pv_solar_radiation_future_in_investment_cost_table
  13. buildings_solar_pv_solar_radiation_opex_in_power_plant_economic_performance_table
  14. buildings_solar_pv_solar_radiation_position_in_power_plant_economic_performance_table
  15. buildings_solar_pv_solar_radiation_present_in_investment_cost_table
  16. buildings_solar_pv_solar_radiation_profit_in_power_plant_economic_performance_table
  17. buildings_solar_pv_solar_radiation_revenue_in_power_plant_economic_performance_table
  18. converter_group_power_plant_per_plant_type_solar_on_roof
  19. costs_of_solar_pv_buildings_in_overview_costs_of_electricity_production
  20. depreciation_costs_buildings_solar_panels_per_kw
  21. depreciation_costs_industry_solar_panels_per_kw
  22. electricity_curtailment_flexible_curve
  23. energy_curtailment_solar_pv_electricity_peak_capacity
  24. investment_for_solar_pv_buildings_in_overview_costs_of_electricity_production
  25. land_use_solar_wind_solar_pv_buildings_capacity_per_unit
  26. land_use_solar_wind_solar_pv_buildings_electricity_output
  27. land_use_solar_wind_solar_pv_buildings_full_load_hours
  28. land_use_solar_wind_solar_pv_buildings_installed_capacity
  29. land_use_solar_wind_solar_pv_buildings_land_use_per_unit
  30. land_use_solar_wind_solar_pv_buildings_number_of_units
  31. loss_of_load_expectation
  32. maximum_number_solar_pv_panels
  33. merit_order_buildings_solar_pv_solar_radiation_availability_in_merit_order_table
  34. merit_order_buildings_solar_pv_solar_radiation_capacity_in_merit_order_table
  35. merit_order_buildings_solar_pv_solar_radiation_full_load_hours_in_merit_order_table
  36. merit_order_buildings_solar_pv_solar_radiation_load_factor_in_merit_order_table
  37. merit_order_buildings_solar_pv_solar_radiation_operating_costs_in_merit_order_table
  38. solar_panels_in_source_of_electricity_in_buildings
  39. solar_pv_total_curtailed_electricity_curve
  40. total_cost_of_buildings_solar_pv_solar_radiation
Used in Inputs
  1. capacity_of_buildings_solar_pv_solar_radiation
  2. curtailment_of_buildings_solar_pv_solar_radiation
  3. efficiency_energy_power_solar_pv_solar_radiation
  4. flh_of_buildings_solar_pv_solar_radiation
  5. flh_of_buildings_solar_pv_solar_radiation_user_curve
  6. investment_costs_solar_solar_panels
  7. settings_weather_curve_set
Method Label Present Future Unit
technical
electricity_output_capacity * number_of_units Installed electrical capacity 2,624.1 2,624.1 MW
electricity_output_capacity Capacity per unit 0 0 MW
electricity_output_conversion Electrical efficiency 17.0 17.0 %
full_load_hours Full load hours 867 867 hour / year
cost
total_investment_over_lifetime_per(:mw_electricity) Investment over lifetime per MW 1300007 1300007 EUR / MW
fixed_operation_and_maintenance_costs_per(:mw_electricity) Fixed operation and maintenance costs 16985 16985 EUR / MW / year
variable_operation_and_maintenance_costs_per_full_load_hour Variable operation and maintenance costs 0 0 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
land_use_per_unit / electricity_output_capacity Land use 0.006 0.006 km2 / MW
technical_lifetime Technical lifetime 25 25 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 00{class: "change"}MWe
heat_output_capacity 00{class: "change"}MWth
hydrogen_output_capacity 00{class: "change"}MW
free_co2_factor 00{class: "change"}
ccs_capture_rate --{class: "change"}
construction_time 0.30.3{class: "change"}
electrical_efficiency_when_using_coal --{class: "change"}
electrical_efficiency_when_using_wood_pellets --{class: "change"}
full_load_hours 867867{class: "change"}
households_supplied_per_unit --{class: "change"}
land_use_per_unit 00{class: "change"}
takes_part_in_ets 00{class: "change"}yes=1 / no=0
technical_lifetime 2525{class: "change"}year
typical_input_capacity --{class: "change"}MWinput
output_capacity --{class: "change"}MW
input_efficiency --{class: "change"}
output_efficiency --{class: "change"}
cost
initial_investment 217.3217.3{class: "change"}euro / unit
ccs_investment 00{class: "change"}euro / unit
cost_of_installing 136.3136.3{class: "change"}euro / unit
decommissioning_costs 00{class: "change"}euro / unit
fixed_operation_and_maintenance_costs_per_year 4.624.62{class: "change"}euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 00{class: "change"}euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 00{class: "change"}euro / full load hour
fixed_costs_per_mw_input_capacity --{class: "change"}euro / MWinput
costs_per_mj --{class: "change"}
wacc 0.040.04{class: "change"}
profitability --{class: "change"}profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity --{class: "change"}eur/MWh
marginal_costs 00{class: "change"}euro / MWh
max_consumption_price 00{class: "change"}euro / MWh
capital_expenditures 21.321.3{class: "change"}euro / unit / year
operating_expenses 4.624.62{class: "change"}euro / unit / year
operating_expenses_including_fuel 4.624.62{class: "change"}euro / unit / year
revenue 08.65{class: "change"}euro / unit / year
merit_order
merit_order_full_load_hours --{class: "change"}
merit_order_capacity_factor --{class: "change"}
merit_order_position --{class: "change"}
security_of_supply
availability 0.980.98{class: "change"}
part_load_operating_point --{class: "change"}
part_load_efficiency_penalty --{class: "change"}
forecasting_error --{class: "change"}
misc
demand_expected_value --{class: "change"}
excel_id --{class: "change"}
max_demand --{class: "change"}
Node Calculations Present Future Change Unit
demand
demand 48.18 B48.18 B{class: "change"}
preset_demand 48.18 B48.18 B{class: "change"}
demand_of_sustainable 00{class: "change"}
weighted_carrier_cost_per_mj 00{class: "change"}
weighted_carrier_co2_per_mj 00{class: "change"}
sustainability_share 11{class: "change"}
primary_demand 8.19 B8.19 B{class: "change"}
primary_demand_of_fossil 00{class: "change"}
primary_demand_of_sustainable 8.19 B8.19 B{class: "change"}
primary_demand_of_electricity 8.19 B8.19 B{class: "change"}
technical
input_capacity 0.0020.002{class: "change"}
electric_based_input_capacity 0.0020.002{class: "change"}MWinput
heat_based_input_capacity --{class: "change"}MWinput
cooling_based_input_capacity --{class: "change"}MWinput
number_of_units 9,647 K9,647 K{class: "change"}
costs_per_plant
total_costs_per(:plant) 25.9225.92{class: "change"}euro / plant
fixed_costs_per(:plant) 25.9225.92{class: "change"}
cost_of_capital_per(:plant) 7.167.16{class: "change"}
depreciation_costs_per(:plant) 14.1414.14{class: "change"}
variable_costs_per(:plant) 00{class: "change"}
fuel_costs_per(:plant) 00{class: "change"}
co2_emissions_costs_per(:plant) 00{class: "change"}
captured_biogenic_co2_costs_per(:plant) 00{class: "change"}
fixed_operation_and_maintenance_costs_per(:plant) 4.624.62{class: "change"}
variable_operation_and_maintenance_costs_per(:plant) 00{class: "change"}
total_initial_investment_per(:plant) 353.6353.6{class: "change"}
costs_per_node
total_costs_per(:node) 250.07 M250.07 M{class: "change"}
fixed_costs_per(:node) 250.07 M250.07 M{class: "change"}
cost_of_capital_per(:node) 69.05 M69.05 M{class: "change"}
depreciation_costs_per(:node) 136.45 M136.45 M{class: "change"}
variable_costs_per(:node) 00{class: "change"}
fuel_costs_per(:node) 00{class: "change"}
co2_emissions_costs_per(:node) 00{class: "change"}
captured_biogenic_co2_costs_per(:node) 00{class: "change"}
fixed_operation_and_maintenance_costs_per(:node) 44.57 M44.57 M{class: "change"}
variable_operation_and_maintenance_costs_per(:node) 00{class: "change"}
total_initial_investment_per(:node) 3.41 B3.41 B{class: "change"}
costs_per_mw_electricity
total_costs_per(:mw_electricity) 95,297.795,297.7{class: "change"}
fixed_costs_per(:mw_electricity) 95,297.795,297.7{class: "change"}
cost_of_capital_per(:mw_electricity) 26,312.126,312.1{class: "change"}
depreciation_costs_per(:mw_electricity) 52,000.352,000.3{class: "change"}
variable_costs_per(:mw_electricity) 00{class: "change"}
fuel_costs_per(:mw_electricity) 00{class: "change"}
co2_emissions_costs_per(:mw_electricity) 00{class: "change"}
captured_biogenic_co2_costs_per(:mw_electricity) 00{class: "change"}
fixed_operation_and_maintenance_costs_per(:mw_electricity) 16,985.316,985.3{class: "change"}
variable_operation_and_maintenance_costs_per(:mw_electricity) 00{class: "change"}
total_initial_investment_per(:mw_electricity) 1,300 K1,300 K{class: "change"}
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 109.9109.9{class: "change"}
fixed_costs_per(:mwh_electricity) 109.9109.9{class: "change"}
cost_of_capital_per(:mwh_electricity) 30.3530.35{class: "change"}
depreciation_costs_per(:mwh_electricity) 59.9859.98{class: "change"}
variable_costs_per(:mwh_electricity) 00{class: "change"}
fuel_costs_per(:mwh_electricity) 00{class: "change"}
co2_emissions_costs_per(:mwh_electricity) 00{class: "change"}
captured_biogenic_co2_costs_per(:mwh_electricity) 00{class: "change"}
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 19.5919.59{class: "change"}
variable_operation_and_maintenance_costs_per(:mwh_electricity) 00{class: "change"}
total_initial_investment_per(:mwh_electricity) 1,499.41,499.4{class: "change"}
costs_per_mw_heat
total_costs_per(:mw_heat) 00{class: "change"}
fixed_costs_per(:mw_heat) 00{class: "change"}
cost_of_capital_per(:mw_heat) 00{class: "change"}
depreciation_costs_per(:mw_heat) 00{class: "change"}
variable_costs_per(:mw_heat) NaNNaN{class: "change"}
fuel_costs_per(:mw_heat) NaNNaN{class: "change"}
co2_emissions_costs_per(:mw_heat) NaNNaN{class: "change"}
captured_biogenic_co2_costs_per(:mw_heat) NaNNaN{class: "change"}
fixed_operation_and_maintenance_costs_per(:mw_heat) 00{class: "change"}
variable_operation_and_maintenance_costs_per(:mw_heat) NaNNaN{class: "change"}
total_initial_investment_per(:mw_heat) 00{class: "change"}
costs_per_mwh_heat
total_costs_per(:mwh_heat) 00{class: "change"}
fixed_costs_per(:mwh_heat) 00{class: "change"}
cost_of_capital_per(:mwh_heat) 00{class: "change"}
depreciation_costs_per(:mwh_heat) 00{class: "change"}
variable_costs_per(:mwh_heat) NaNNaN{class: "change"}
fuel_costs_per(:mwh_heat) NaNNaN{class: "change"}
co2_emissions_costs_per(:mwh_heat) NaNNaN{class: "change"}
captured_biogenic_co2_costs_per(:mwh_heat) NaNNaN{class: "change"}
fixed_operation_and_maintenance_costs_per(:mwh_heat) 00{class: "change"}
variable_operation_and_maintenance_costs_per(:mwh_heat) NaNNaN{class: "change"}
total_initial_investment_per(:mwh_heat) 00{class: "change"}