Present 3.4 B 3.4 B 3.4 B
Future 3.4 B 3.4 B 3.4 B
Edges 3.4 B Outputs
18.0 %
Node MJ Type
buildings_space_heater_wood_pellets_aggregator 2.79 B Share
82.0 %
Inputs Edges 3.4 B
100.0 %
Type MJ Node
Share 3.4 B buildings_final_demand_for_space_heating_wood_pellets
Edges 3.4 B Outputs
18.0 %
Node MJ Type
buildings_space_heater_wood_pellets_aggregator 2.79 B Share
82.0 %
Inputs Edges 3.4 B
100.0 %
Type MJ Node
Share 3.4 B buildings_final_demand_for_space_heating_wood_pellets

Details

Sector buildings
Use energetic
Fever (Heat)
defer_for
4
group
buildings_space_heating
share_in_group
0.017807478790624717
technology_curve_type
tech_day_night
type
producer
Node groups
  1. demand_driven
  2. heat_production
  3. application_group
  4. aggregator_producer
  5. wacc_proven_tech
  6. costs_building_and_installations_buildings
  7. ht_delivery_system_buildings
Used in Gqueries
  1. buildings_space_heater_wood_pellets_delta_in_investment_cost_table
  2. buildings_space_heater_wood_pellets_future_in_investment_cost_table
  3. buildings_space_heater_wood_pellets_present_in_investment_cost_table
  4. total_cost_of_buildings_space_heater_wood_pellets
  5. turk_number_of_units_of_buildings_space_heater_wood_pellets
Used in Inputs
  1. buildings_space_heater_wood_pellets_share
  2. efficiency_buildings_space_heater_wood_pellets
Method Label Present Future Unit
technical
heat_output_conversion Heat efficiency (LHV) 82.0 82.0 %
heat_output_capacity Heat capacity per unit 0.137 0.137 MW / unit
full_load_hours Full load hours 347.7 347.7 hour / year
cost
total_investment_over_lifetime_per(:plant) Investment over lifetime per plant 34,318.5 34,318.5 EUR / unit
fixed_operation_and_maintenance_costs_per(:plant) Fixed operation and maintenance costs 1,644 1,644 EUR / unit / year
variable_operation_and_maintenance_costs_per(:full_load_hour) Variable operation and maintenance costs 0 0 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
technical_lifetime Technical lifetime 15 15 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 0 0 MWe
heat_output_capacity 0.137 0.137 0% MWth
hydrogen_output_capacity 0 0 MW
free_co2_factor 0 0
ccs_capture_rate - -
construction_time 0 0
electrical_efficiency_when_using_coal - -
electrical_efficiency_when_using_wood_pellets - -
full_load_hours 347.7 347.7 0%
households_supplied_per_unit 1 1 0%
land_use_per_unit - -
takes_part_in_ets 0 0 yes=1 / no=0
technical_lifetime 15 15 0% year
typical_input_capacity - - MWinput
output_capacity - - MW
input_efficiency - -
output_efficiency - -
cost
initial_investment 34,318.5 34,318.5 0% euro / unit
ccs_investment 0 0 euro / unit
cost_of_installing 0 0 euro / unit
decommissioning_costs 0 0 euro / unit
fixed_operation_and_maintenance_costs_per_year 1,644 1,644 0% euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 0 0 euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 0 0 euro / full load hour
fixed_costs_per_mw_input_capacity - - euro / MWinput
costs_per_mj - -
wacc 0.04 0.04 0%
profitability - - profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity - - eur/MWh
marginal_costs - - euro / MWh
max_consumption_price - - euro / MWh
merit_order
merit_order_full_load_hours - -
merit_order_capacity_factor - -
merit_order_position - -
security_of_supply
availability 0 0
part_load_operating_point - -
part_load_efficiency_penalty - -
forecasting_error - -
misc
demand_expected_value 3.4 B 3.4 B 0%
excel_id - -
max_demand - -
Node Calculations Present Future Change Unit
demand
demand 3.4 B 3.4 B 0%
preset_demand - -
demand_of_sustainable 0 0
weighted_carrier_cost_per_mj 0.008 0.008 0%
weighted_carrier_co2_per_mj 0 0
sustainability_share 1 1 0%
final_demand 3.4 B 3.4 B 0%
primary_demand 3.4 B 3.4 B 0%
primary_demand_of_fossil 0 0
primary_demand_of_sustainable 3.4 B 3.4 B 0%
primary_demand_of_wood_pellets 3.4 B 3.4 B 0%
technical
input_capacity 0.167 0.167 0%
electric_based_input_capacity - - MWinput
heat_based_input_capacity 0.167 0.167 0% MWinput
cooling_based_input_capacity - - MWinput
number_of_units 16,249.3 16,249.3 0%
costs_per_plant
total_costs_per(:plant) 6,358.6 6,358.6 0% euro / plant
fixed_costs_per(:plant) 4,618.3 4,618.3 0%
cost_of_capital_per(:plant) 686.4 686.4 0%
depreciation_costs_per(:plant) 2,287.9 2,287.9 0%
variable_costs_per(:plant) 1,740.3 1,740.3 0%
fuel_costs_per(:plant) 1,740.3 1,740.3 0%
co2_emissions_costs_per(:plant) 0 0
captured_biogenic_co2_costs_per(:plant) 0 0
fixed_operation_and_maintenance_costs_per(:plant) 1,644 1,644 0%
variable_operation_and_maintenance_costs_per(:plant) 0 0
total_initial_investment_per(:plant) 34,318.5 34,318.5 0%
costs_per_node
total_costs_per(:node) 103.32 M 103.32 M 0%
fixed_costs_per(:node) 75.04 M 75.04 M 0%
cost_of_capital_per(:node) 11.15 M 11.15 M 0%
depreciation_costs_per(:node) 37.18 M 37.18 M 0%
variable_costs_per(:node) 28.28 M 28.28 M 0%
fuel_costs_per(:node) 28.28 M 28.28 M 0%
co2_emissions_costs_per(:node) 0 0
captured_biogenic_co2_costs_per(:node) 0 0
fixed_operation_and_maintenance_costs_per(:node) 26.71 M 26.71 M 0%
variable_operation_and_maintenance_costs_per(:node) 0 0
total_initial_investment_per(:node) 557.65 M 557.65 M 0%
costs_per_mw_electricity
total_costs_per(:mw_electricity) 0 0
fixed_costs_per(:mw_electricity) 0 0
cost_of_capital_per(:mw_electricity) 0 0
depreciation_costs_per(:mw_electricity) 0 0
variable_costs_per(:mw_electricity) 0 0
fuel_costs_per(:mw_electricity) 0 0
co2_emissions_costs_per(:mw_electricity) NaN NaN
captured_biogenic_co2_costs_per(:mw_electricity) NaN NaN
fixed_operation_and_maintenance_costs_per(:mw_electricity) 0 0
variable_operation_and_maintenance_costs_per(:mw_electricity) NaN NaN
total_initial_investment_per(:mw_electricity) 0 0
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 0 0
fixed_costs_per(:mwh_electricity) 0 0
cost_of_capital_per(:mwh_electricity) 0 0
depreciation_costs_per(:mwh_electricity) 0 0
variable_costs_per(:mwh_electricity) 0 0
fuel_costs_per(:mwh_electricity) 0 0
co2_emissions_costs_per(:mwh_electricity) NaN NaN
captured_biogenic_co2_costs_per(:mwh_electricity) NaN NaN
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 0 0
variable_operation_and_maintenance_costs_per(:mwh_electricity) NaN NaN
total_initial_investment_per(:mwh_electricity) 0 0
costs_per_mw_heat
total_costs_per(:mw_heat) 46,413 46,413 0%
fixed_costs_per(:mw_heat) 33,710 33,710 0%
cost_of_capital_per(:mw_heat) 5,010 5,010 0%
depreciation_costs_per(:mw_heat) 16,700 16,700 0%
variable_costs_per(:mw_heat) 12,703 12,703 0%
fuel_costs_per(:mw_heat) 12,703 12,703 0%
co2_emissions_costs_per(:mw_heat) 0 0
captured_biogenic_co2_costs_per(:mw_heat) 0 0
fixed_operation_and_maintenance_costs_per(:mw_heat) 12,000 12,000 0%
variable_operation_and_maintenance_costs_per(:mw_heat) 0 0
total_initial_investment_per(:mw_heat) 250 K 250 K 0%
costs_per_mwh_heat
total_costs_per(:mwh_heat) 133.5 133.5 0%
fixed_costs_per(:mwh_heat) 96.94 96.94 0%
cost_of_capital_per(:mwh_heat) 14.41 14.41 0%
depreciation_costs_per(:mwh_heat) 48.03 48.03 0%
variable_costs_per(:mwh_heat) 36.53 36.53 0%
fuel_costs_per(:mwh_heat) 36.53 36.53 0%
co2_emissions_costs_per(:mwh_heat) 0 0
captured_biogenic_co2_costs_per(:mwh_heat) 0 0
fixed_operation_and_maintenance_costs_per(:mwh_heat) 34.51 34.51 0%
variable_operation_and_maintenance_costs_per(:mwh_heat) 0 0
total_initial_investment_per(:mwh_heat) 720.4 720.4 0%