Present 0 0 0
Future 0 0 0
Edges 0 Outputs
Node MJ Type
energy_battery_curtailed_solar_electricity 0 Share
Reversed
energy_battery_solar_electricity 0 Share
Reversed
energy_flexibility_solar_batteries_electricity 0 Share
Reversed
17.0 %
83.0 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 environment_sun_solar_radiation
Edges 0 Outputs
Node MJ Type
energy_battery_curtailed_solar_electricity 0 Share
Reversed
energy_battery_solar_electricity 0 Share
Reversed
energy_flexibility_solar_batteries_electricity 0 Share
Reversed
17.0 %
83.0 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 environment_sun_solar_radiation

Details

Sector energy
Use energetic
Merit Order
group
dynamic: solar_pv
level
hv
relations
curtailment: energy_battery_curtailed_solar_electricity output: energy_battery_solar_electricity storage: energy_flexibility_solar_batteries_electricity
subtype
always_on_battery_park
type
producer
Node groups
  1. preset_demand
  2. primary_energy_demand
  3. sustainable_production
  4. volatile_production
  5. wacc_proven_tech
  6. costs_production_power_plants
  7. merit_order_csv_exclude
Used in Gqueries
  1. energy_battery_solar_direct_to_grid_electricity_output
  2. energy_battery_solar_pv_curtailed_electricity_percentage
  3. energy_battery_solar_pv_installed_capacity
  4. energy_battery_solar_pv_peak_power_before_curtailment
  5. energy_battery_solar_pv_production_before_curtailment
  6. factsheet_installed_capacity_of_solar_pv
  7. factsheet_solar_pv_plants_land_use
  8. factsheet_supply_from_solar_pv_plants
  9. land_use_solar_wind_battery_solar_pv_capacity_per_unit
  10. land_use_solar_wind_battery_solar_pv_electricity_output
  11. land_use_solar_wind_battery_solar_pv_full_load_hours
  12. land_use_solar_wind_battery_solar_pv_installed_capacity
  13. land_use_solar_wind_battery_solar_pv_land_use_per_unit
  14. land_use_solar_wind_battery_solar_pv_number_of_units
  15. merit_order_battery_solar_pv_availability_in_merit_order_table
  16. merit_order_battery_solar_pv_capacity_in_merit_order_table
  17. merit_order_battery_solar_pv_full_load_hours_in_merit_order_table
  18. merit_order_battery_solar_pv_load_factor_in_merit_order_table
  19. merit_order_battery_solar_pv_operating_costs_in_merit_order_table
Used in Inputs
  1. capacity_of_energy_battery_solar_pv_solar_radiation
  2. efficiency_energy_power_solar_pv_solar_radiation
  3. flh_of_solar_pv_solar_radiation
  4. flh_of_solar_pv_solar_radiation_user_curve
  5. investment_costs_solar_solar_panels
Method Label Present Future Unit
technical
electricity_output_capacity * number_of_units Installed electrical capacity 0 0 MW
electricity_output_conversion Electrical efficiency 17.0 17.0 %
full_load_hours Full load hours 867 867 hour / year
cost
total_investment_over_lifetime_per(:mw_electricity) Investment over lifetime per MW 871000 871000 EUR / MW
fixed_operation_and_maintenance_costs_per(:mw_electricity) Fixed operation and maintenance costs 15900 15900 EUR / MW / year
variable_operation_and_maintenance_costs_per_full_load_hour Variable operation and maintenance costs 0 0 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
land_use_per_unit / electricity_output_capacity Land use 0.01 0.01 km2 / MW
technical_lifetime Technical lifetime 25 25 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 20 20 0% MWe
heat_output_capacity 0 0 MWth
hydrogen_output_capacity 0 0 MW
free_co2_factor 0 0
ccs_capture_rate - -
construction_time 0.5 0.5 0%
electrical_efficiency_when_using_coal - -
electrical_efficiency_when_using_wood_pellets - -
full_load_hours 867 867 0%
households_supplied_per_unit - -
land_use_per_unit 0.2 0.2 0%
takes_part_in_ets 0 0 yes=1 / no=0
technical_lifetime 25 25 0% year
typical_input_capacity - - MWinput
output_capacity - - MW
input_efficiency - -
output_efficiency - -
cost
initial_investment 17.42 M 17.42 M 0% euro / unit
ccs_investment 0 0 euro / unit
cost_of_installing 0 0 euro / unit
decommissioning_costs 0 0 euro / unit
fixed_operation_and_maintenance_costs_per_year 318 K 318 K 0% euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 0 0 euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 0 0 euro / full load hour
fixed_costs_per_mw_input_capacity - - euro / MWinput
costs_per_mj - -
wacc 0.04 0.04 0%
profitability - - profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity - - eur/MWh
marginal_costs 0 0 euro / MWh
max_consumption_price 0 0 euro / MWh
merit_order
merit_order_full_load_hours - -
merit_order_capacity_factor - -
merit_order_position - -
security_of_supply
availability 0.98 0.98 0%
part_load_operating_point 0.7 0.7 0%
part_load_efficiency_penalty 0.1 0.1 0%
forecasting_error 0.05 0.05 0%
misc
demand_expected_value - -
excel_id - -
max_demand - -
Node Calculations Present Future Change Unit
demand
demand 0 0
preset_demand 0 0
demand_of_sustainable 0 0
weighted_carrier_cost_per_mj 0 0
weighted_carrier_co2_per_mj 0 0
sustainability_share 1 1 0%
final_demand 0 0
primary_demand 0 0
primary_demand_of_fossil 0 0
primary_demand_of_sustainable 0 0
technical
input_capacity 117.6 117.6 0%
electric_based_input_capacity 117.6 117.6 0% MWinput
heat_based_input_capacity - - MWinput
cooling_based_input_capacity - - MWinput
number_of_units 0 0
costs_per_plant
total_costs_per(:plant) 1,370 K 1,370 K 0% euro / plant
fixed_costs_per(:plant) 1,370 K 1,370 K 0%
cost_of_capital_per(:plant) 355 K 355 K 0%
depreciation_costs_per(:plant) 697 K 697 K 0%
variable_costs_per(:plant) 0 0
fuel_costs_per(:plant) 0 0
co2_emissions_costs_per(:plant) 0 0
captured_biogenic_co2_costs_per(:plant) 0 0
fixed_operation_and_maintenance_costs_per(:plant) 318 K 318 K 0%
variable_operation_and_maintenance_costs_per(:plant) 0 0
total_initial_investment_per(:plant) 17.42 M 17.42 M 0%
costs_per_node
total_costs_per(:node) 0 0
fixed_costs_per(:node) 0 0
cost_of_capital_per(:node) 0 0
depreciation_costs_per(:node) 0 0
variable_costs_per(:node) 0 0
fuel_costs_per(:node) 0 0
co2_emissions_costs_per(:node) 0 0
captured_biogenic_co2_costs_per(:node) 0 0
fixed_operation_and_maintenance_costs_per(:node) 0 0
variable_operation_and_maintenance_costs_per(:node) 0 0
total_initial_investment_per(:node) 0 0
costs_per_mw_electricity
total_costs_per(:mw_electricity) 68,508.4 68,508.4 0%
fixed_costs_per(:mw_electricity) 68,508.4 68,508.4 0%
cost_of_capital_per(:mw_electricity) 17,768.4 17,768.4 0%
depreciation_costs_per(:mw_electricity) 34,840 34,840 0%
variable_costs_per(:mw_electricity) 0 0
fuel_costs_per(:mw_electricity) 0 0
co2_emissions_costs_per(:mw_electricity) 0 0
captured_biogenic_co2_costs_per(:mw_electricity) 0 0
fixed_operation_and_maintenance_costs_per(:mw_electricity) 15,900 15,900 0%
variable_operation_and_maintenance_costs_per(:mw_electricity) 0 0
total_initial_investment_per(:mw_electricity) 871 K 871 K 0%
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 79.02 79.02 0%
fixed_costs_per(:mwh_electricity) 79.02 79.02 0%
cost_of_capital_per(:mwh_electricity) 20.49 20.49 0%
depreciation_costs_per(:mwh_electricity) 40.18 40.18 0%
variable_costs_per(:mwh_electricity) 0 0
fuel_costs_per(:mwh_electricity) 0 0
co2_emissions_costs_per(:mwh_electricity) 0 0
captured_biogenic_co2_costs_per(:mwh_electricity) 0 0
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 18.34 18.34 0%
variable_operation_and_maintenance_costs_per(:mwh_electricity) 0 0
total_initial_investment_per(:mwh_electricity) 1,004.6 1,004.6 0%
costs_per_mw_heat
total_costs_per(:mw_heat) 0 0
fixed_costs_per(:mw_heat) 0 0
cost_of_capital_per(:mw_heat) 0 0
depreciation_costs_per(:mw_heat) 0 0
variable_costs_per(:mw_heat) NaN NaN
fuel_costs_per(:mw_heat) NaN NaN
co2_emissions_costs_per(:mw_heat) NaN NaN
captured_biogenic_co2_costs_per(:mw_heat) NaN NaN
fixed_operation_and_maintenance_costs_per(:mw_heat) 0 0
variable_operation_and_maintenance_costs_per(:mw_heat) NaN NaN
total_initial_investment_per(:mw_heat) 0 0
costs_per_mwh_heat
total_costs_per(:mwh_heat) 0 0
fixed_costs_per(:mwh_heat) 0 0
cost_of_capital_per(:mwh_heat) 0 0
depreciation_costs_per(:mwh_heat) 0 0
variable_costs_per(:mwh_heat) NaN NaN
fuel_costs_per(:mwh_heat) NaN NaN
co2_emissions_costs_per(:mwh_heat) NaN NaN
captured_biogenic_co2_costs_per(:mwh_heat) NaN NaN
fixed_operation_and_maintenance_costs_per(:mwh_heat) 0 0
variable_operation_and_maintenance_costs_per(:mwh_heat) NaN NaN
total_initial_investment_per(:mwh_heat) 0 0