Present 0 0 0
Future 0 0 0
Edges 0 Outputs
Node MJ Type
energy_power_mv_distribution_network_electricity 0 Flexible
Reversed
39.2 %
10.8 %
Node MJ Type
energy_production_aggregator_mt_steam_hot_water 0 Flexible
Reversed
50.0 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_national_gas_network_natural_gas
Edges 0 Outputs
Node MJ Type
energy_power_mv_distribution_network_electricity 0 Flexible
Reversed
39.2 %
10.8 %
Node MJ Type
energy_production_aggregator_mt_steam_hot_water 0 Flexible
Reversed
50.0 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_national_gas_network_natural_gas

Details

Sector energy
Use energetic
Heat network (MT)
group
self: electricity_output_curve
subtype
must_run
type
producer
Merit Order
level
mv
subtype
dispatchable
type
producer
Network Gas
profile
self: electricity_output_curve
type
consumer
Node groups
  1. preset_demand
  2. electricity_production
  3. heat_production
  4. dispatchable_production
  5. wacc_proven_tech
  6. costs_production_chp_plants
  7. sankey_conversion_group
Used in Gqueries
  1. energy_chp_local_engine_mt_network_gas_capacity_in_chp_properties
  2. energy_chp_local_engine_mt_network_gas_electricity_production_in_chp_properties
  3. energy_chp_local_engine_mt_network_gas_heat_production_in_chp_properties
  4. energy_chp_local_engine_mt_network_gas_number_of_units_in_chp_properties
  5. energy_chp_local_engine_network_gas
  6. energy_chp_local_engine_network_gas_mt_steam_hot_water_output_curve
  7. factsheet_supply_heat_from_rest_and_geothermal
  8. merit_order_gas_chp_engine_mt_availability_in_merit_order_table
  9. merit_order_gas_chp_engine_mt_capacity_in_merit_order_table
  10. merit_order_gas_chp_engine_mt_full_load_hours_in_merit_order_table
  11. merit_order_gas_chp_engine_mt_load_factor_in_merit_order_table
  12. merit_order_gas_chp_engine_mt_operating_costs_in_merit_order_table
  13. merit_order_gas_chp_engine_mt_position_in_merit_order_table
Used in Inputs
  1. capacity_of_energy_chp_local_engine_network_gas
  2. efficiency_energy_chp_local_engine_network_gas_electricity
  3. efficiency_energy_chp_local_engine_network_gas_heat
  4. investment_costs_combustion_gas_plant
  5. om_costs_combustion_gas_plant
  6. share_of_energy_chp_local_engine_ht_network_gas
  7. share_of_energy_chp_local_engine_mt_network_gas
Method Label Present Future Unit
technical
electricity_output_capacity * number_of_units Installed electrical capacity 0 0 MW
electricity_output_conversion Electrical efficiency 39.2 39.2 %
heat_output_conversion Heat efficiency 50.0 50.0 %
full_load_hours Full load hours 8,500 0 hour / year
cost
total_investment_over_lifetime_per(:mw_electricity) Investment over lifetime per MW 651324 651324 EUR / MW
fixed_operation_and_maintenance_costs_per(:mw_electricity) Fixed operation and maintenance costs 0 0 EUR / MW / year
variable_operation_and_maintenance_costs_per_full_load_hour Variable operation and maintenance costs 16 16 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
technical_lifetime Technical lifetime 20 20 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 1.84 1.84 0% MWe
heat_output_capacity 2.35 2.35 0% MWth
hydrogen_output_capacity 0 0 MW
free_co2_factor 0 0
ccs_capture_rate - -
construction_time 1.1 1.1 0%
electrical_efficiency_when_using_coal - -
electrical_efficiency_when_using_wood_pellets - -
full_load_hours 8,500 0 -100%
households_supplied_per_unit - -
land_use_per_unit - -
takes_part_in_ets 0 0 yes=1 / no=0
technical_lifetime 20 20 0% year
typical_input_capacity 4.7 4.7 0% MWinput
output_capacity - - MW
input_efficiency - -
output_efficiency - -
cost
initial_investment 1,200 K 1,200 K 0% euro / unit
ccs_investment 0 0 euro / unit
cost_of_installing 0 0 euro / unit
decommissioning_costs 0 0 euro / unit
fixed_operation_and_maintenance_costs_per_year 0 0 euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 16 16 0% euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 0 0 euro / full load hour
fixed_costs_per_mw_input_capacity - - euro / MWinput
costs_per_mj - -
wacc 0.04 0.04 0%
profitability - profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity - - eur/MWh
marginal_costs 44.98 44.98 0% euro / MWh
max_consumption_price 44.98 44.98 0% euro / MWh
merit_order
merit_order_full_load_hours - -
merit_order_capacity_factor - -
merit_order_position - -
security_of_supply
availability 0.95 0.95 0%
part_load_operating_point - -
part_load_efficiency_penalty - -
forecasting_error - -
misc
demand_expected_value - -
excel_id - -
max_demand - -
Node Calculations Present Future Change Unit
demand
demand 0 0
preset_demand 0 0
demand_of_sustainable 0 0
weighted_carrier_cost_per_mj 0.004 0.004 0%
weighted_carrier_co2_per_mj 0.056 0.056 0%
sustainability_share 0.005 0.005 0%
final_demand 0 0
primary_demand 0 0
primary_demand_of_fossil 0 0
primary_demand_of_sustainable 0 0
technical
input_capacity 4.7 4.7 0%
electric_based_input_capacity 4.7 4.7 0% MWinput
heat_based_input_capacity 4.7 4.7 0% MWinput
cooling_based_input_capacity - - MWinput
number_of_units 0 0
costs_per_plant
total_costs_per(:plant) 790 K 85,320 -89% euro / plant
fixed_costs_per(:plant) 85,320 85,320 0%
cost_of_capital_per(:plant) 25,320 25,320 0%
depreciation_costs_per(:plant) 60,000 60,000 0%
variable_costs_per(:plant) 704 K 0 -100%
fuel_costs_per(:plant) 568 K 0 -100%
co2_emissions_costs_per(:plant) 0 0
captured_biogenic_co2_costs_per(:plant) 0 0
fixed_operation_and_maintenance_costs_per(:plant) 0 0
variable_operation_and_maintenance_costs_per(:plant) 136 K 0 -100%
total_initial_investment_per(:plant) 1,200 K 1,200 K 0%
costs_per_node
total_costs_per(:node) 0 0
fixed_costs_per(:node) 0 0
cost_of_capital_per(:node) 0 0
depreciation_costs_per(:node) 0 0
variable_costs_per(:node) 0 0
fuel_costs_per(:node) 0 0
co2_emissions_costs_per(:node) 0 0
captured_biogenic_co2_costs_per(:node) 0 0
fixed_operation_and_maintenance_costs_per(:node) 0 0
variable_operation_and_maintenance_costs_per(:node) 0 0
total_initial_investment_per(:node) 0 0
costs_per_mw_electricity
total_costs_per(:mw_electricity) 429 K 46,309.2 -89%
fixed_costs_per(:mw_electricity) 46,309.2 46,309.2 0%
cost_of_capital_per(:mw_electricity) 13,742.9 13,742.9 0%
depreciation_costs_per(:mw_electricity) 32,566.2 32,566.2 0%
variable_costs_per(:mw_electricity) 382 K 0 -100%
fuel_costs_per(:mw_electricity) 308 K 0 -100%
co2_emissions_costs_per(:mw_electricity) 0 0
captured_biogenic_co2_costs_per(:mw_electricity) 0 0
fixed_operation_and_maintenance_costs_per(:mw_electricity) 0 0
variable_operation_and_maintenance_costs_per(:mw_electricity) 73,816.8 0 -100%
total_initial_investment_per(:mw_electricity) 651 K 651 K 0%
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 50.43 0 -100%
fixed_costs_per(:mwh_electricity) 5.45 0 -100%
cost_of_capital_per(:mwh_electricity) 1.62 0 -100%
depreciation_costs_per(:mwh_electricity) 3.83 0 -100%
variable_costs_per(:mwh_electricity) 44.98 NaN
fuel_costs_per(:mwh_electricity) 36.29 NaN
co2_emissions_costs_per(:mwh_electricity) 0 NaN
captured_biogenic_co2_costs_per(:mwh_electricity) 0 NaN
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 0 NaN
variable_operation_and_maintenance_costs_per(:mwh_electricity) 8.68 NaN
total_initial_investment_per(:mwh_electricity) 76.63 0 -100%
costs_per_mw_heat
total_costs_per(:mw_heat) 336 K 36,306.4 -89%
fixed_costs_per(:mw_heat) 36,306.4 36,306.4 0%
cost_of_capital_per(:mw_heat) 10,774.5 10,774.5 0%
depreciation_costs_per(:mw_heat) 25,531.9 25,531.9 0%
variable_costs_per(:mw_heat) 300 K 0 -100%
fuel_costs_per(:mw_heat) 242 K 0 -100%
co2_emissions_costs_per(:mw_heat) 0 0
captured_biogenic_co2_costs_per(:mw_heat) 0 0
fixed_operation_and_maintenance_costs_per(:mw_heat) 0 0
variable_operation_and_maintenance_costs_per(:mw_heat) 57,872.3 0 -100%
total_initial_investment_per(:mw_heat) 511 K 511 K 0%
costs_per_mwh_heat
total_costs_per(:mwh_heat) 39.53 0 -100%
fixed_costs_per(:mwh_heat) 4.27 0 -100%
cost_of_capital_per(:mwh_heat) 1.27 0 -100%
depreciation_costs_per(:mwh_heat) 3 0 -100%
variable_costs_per(:mwh_heat) 35.26 NaN
fuel_costs_per(:mwh_heat) 28.45 NaN
co2_emissions_costs_per(:mwh_heat) 0 NaN
captured_biogenic_co2_costs_per(:mwh_heat) 0 NaN
fixed_operation_and_maintenance_costs_per(:mwh_heat) 0 NaN
variable_operation_and_maintenance_costs_per(:mwh_heat) 6.81 NaN
total_initial_investment_per(:mwh_heat) 60.08 0 -100%