Present 256.6 B 256.6 B 256.6 B
Future 236.84 B 236.84 B 236.84 B
-7.7%
Edges 256.6 B Outputs
Node MJ Type
energy_power_mv_distribution_network_electricity 256.6 B Flexible
energy_power_transformer_mv_hv_electricity 0 Inversed flexible
100.0 %
Inputs Edges 256.6 B
100.0 %
Type MJ Node
Inversed flexible 0 energy_power_mv_distribution_network_electricity
Flexible 256.6 B energy_power_transformer_mv_hv_electricity
Edges 236.84 B Outputs
Node MJ Type
energy_power_mv_distribution_network_electricity 236.84 B Flexible
energy_power_transformer_mv_hv_electricity 0 Inversed flexible
100.0 %
Inputs Edges 236.84 B
100.0 %
Type MJ Node
Inversed flexible 0 energy_power_mv_distribution_network_electricity
Flexible 236.84 B energy_power_transformer_mv_hv_electricity

Details

Sector energy
Use undefined
Node groups
  1. wacc_public_infra
  2. sankey_conversion_group
Used in Gqueries
  1. total_cost_of_energy_power_mv_transport_network_electricity
Used in Inputs
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 16.9 16.9 0% MWe
heat_output_capacity 0 0 MWth
hydrogen_output_capacity 0 0 MW
free_co2_factor 0 0
ccs_capture_rate - -
construction_time 0 0
electrical_efficiency_when_using_coal - -
electrical_efficiency_when_using_wood_pellets - -
full_load_hours 8,760 8,760 0%
households_supplied_per_unit - -
land_use_per_unit - -
takes_part_in_ets 0 0 yes=1 / no=0
technical_lifetime 40 40 0% year
typical_input_capacity - - MWinput
output_capacity - - MW
input_efficiency - -
output_efficiency - -
cost
initial_investment 0 0 euro / unit
ccs_investment 0 0 euro / unit
cost_of_installing 0 0 euro / unit
decommissioning_costs 0 0 euro / unit
fixed_operation_and_maintenance_costs_per_year 86,884.5 86,884.5 0% euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 0 0 euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 0 0 euro / full load hour
fixed_costs_per_mw_input_capacity - - euro / MWinput
costs_per_mj - -
wacc 0.03 0.03 0%
profitability - - profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity - - eur/MWh
marginal_costs 10.75 10.36 -3% euro / MWh
max_consumption_price 10.75 10.36 -3% euro / MWh
merit_order
merit_order_full_load_hours - -
merit_order_capacity_factor - -
merit_order_position - -
security_of_supply
availability 0 0
part_load_operating_point 0 0
part_load_efficiency_penalty 0 0
forecasting_error 0 0
misc
demand_expected_value 256.6 B 256.6 B 0%
excel_id - -
max_demand - -
Node Calculations Present Future Change Unit
demand
demand 256.6 B 236.84 B -7%
preset_demand - -
demand_of_sustainable 0 0
weighted_carrier_cost_per_mj 0.003 0.003 -3%
weighted_carrier_co2_per_mj 0 0
sustainability_share 0.211 0.159 -24%
final_demand 0 0
primary_demand 498.03 B 442.22 B -11%
primary_demand_of_fossil 393.01 B 371.87 B -5%
primary_demand_of_sustainable 105.02 B 70.36 B -33%
primary_demand_of_wood_pellets 16.76 B 0 -100%
primary_demand_of_biogas 1.01 B 1.07 B 5%
primary_demand_of_electricity 41.77 B 29.85 B -28%
primary_demand_of_coal 135.75 B 101.41 B -25%
primary_demand_of_lng 3.23 B 3.42 B 5%
primary_demand_of_natural_gas 218.46 B 231.47 B 5%
primary_demand_of_biogenic_waste 17.68 B 22.69 B 28%
primary_demand_of_non_biogenic_waste 15.68 B 20.12 B 28%
primary_demand_of_uranium_oxide 36.33 B 26.53 B -26%
primary_demand_of_imported_electricity 11.36 B 5.67 B -50%
technical
input_capacity 16.9 16.9 0%
electric_based_input_capacity 16.9 16.9 0% MWinput
heat_based_input_capacity - - MWinput
cooling_based_input_capacity - - MWinput
number_of_units 481.5 444.4 -7%
costs_per_plant
total_costs_per(:plant) 1,678 K 1,620 K -3% euro / plant
fixed_costs_per(:plant) 86,884.5 86,884.5 0%
cost_of_capital_per(:plant) 0 0
depreciation_costs_per(:plant) 0 0
variable_costs_per(:plant) 1,592 K 1,533 K -3%
fuel_costs_per(:plant) 1,592 K 1,533 K -3%
co2_emissions_costs_per(:plant) 0 0
captured_biogenic_co2_costs_per(:plant) 0 0
fixed_operation_and_maintenance_costs_per(:plant) 86,884.5 86,884.5 0%
variable_operation_and_maintenance_costs_per(:plant) 0 0
total_initial_investment_per(:plant) 0 0
costs_per_node
total_costs_per(:node) 808.14 M 719.89 M -10%
fixed_costs_per(:node) 41.83 M 38.61 M -7%
cost_of_capital_per(:node) 0 0
depreciation_costs_per(:node) 0 0
variable_costs_per(:node) 766.31 M 681.28 M -11%
fuel_costs_per(:node) 766.31 M 681.28 M -11%
co2_emissions_costs_per(:node) 0 0
captured_biogenic_co2_costs_per(:node) 0 0
fixed_operation_and_maintenance_costs_per(:node) 41.83 M 38.61 M -7%
variable_operation_and_maintenance_costs_per(:node) 0 0
total_initial_investment_per(:node) 0 0
costs_per_mw_electricity
total_costs_per(:mw_electricity) 99,319.1 95,855.5 -3%
fixed_costs_per(:mw_electricity) 5,141.1 5,141.1 0%
cost_of_capital_per(:mw_electricity) 0 0
depreciation_costs_per(:mw_electricity) 0 0
variable_costs_per(:mw_electricity) 94,178 90,714.4 -3%
fuel_costs_per(:mw_electricity) 94,178 90,714.4 -3%
co2_emissions_costs_per(:mw_electricity) 0 0
captured_biogenic_co2_costs_per(:mw_electricity) 0 0
fixed_operation_and_maintenance_costs_per(:mw_electricity) 5,141.1 5,141.1 0%
variable_operation_and_maintenance_costs_per(:mw_electricity) 0 0
total_initial_investment_per(:mw_electricity) 0 0
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 11.34 10.94 -3%
fixed_costs_per(:mwh_electricity) 0.587 0.587 0%
cost_of_capital_per(:mwh_electricity) 0 0
depreciation_costs_per(:mwh_electricity) 0 0
variable_costs_per(:mwh_electricity) 10.75 10.36 -3%
fuel_costs_per(:mwh_electricity) 10.75 10.36 -3%
co2_emissions_costs_per(:mwh_electricity) 0 0
captured_biogenic_co2_costs_per(:mwh_electricity) 0 0
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 0.587 0.587 0%
variable_operation_and_maintenance_costs_per(:mwh_electricity) 0 0
total_initial_investment_per(:mwh_electricity) 0 0
costs_per_mw_heat
total_costs_per(:mw_heat) 0 0
fixed_costs_per(:mw_heat) 0 0
cost_of_capital_per(:mw_heat) NaN NaN
depreciation_costs_per(:mw_heat) NaN NaN
variable_costs_per(:mw_heat) 0 0
fuel_costs_per(:mw_heat) 0 0
co2_emissions_costs_per(:mw_heat) NaN NaN
captured_biogenic_co2_costs_per(:mw_heat) NaN NaN
fixed_operation_and_maintenance_costs_per(:mw_heat) 0 0
variable_operation_and_maintenance_costs_per(:mw_heat) NaN NaN
total_initial_investment_per(:mw_heat) NaN NaN
costs_per_mwh_heat
total_costs_per(:mwh_heat) 0 0
fixed_costs_per(:mwh_heat) 0 0
cost_of_capital_per(:mwh_heat) NaN NaN
depreciation_costs_per(:mwh_heat) NaN NaN
variable_costs_per(:mwh_heat) 0 0
fuel_costs_per(:mwh_heat) 0 0
co2_emissions_costs_per(:mwh_heat) NaN NaN
captured_biogenic_co2_costs_per(:mwh_heat) NaN NaN
fixed_operation_and_maintenance_costs_per(:mwh_heat) 0 0
variable_operation_and_maintenance_costs_per(:mwh_heat) NaN NaN
total_initial_investment_per(:mwh_heat) NaN NaN