Present 52.32 B 52.32 B 52.32 B
Future 52.32 B 52.32 B 52.32 B
Edges 52.32 B Outputs
Node MJ Type
households_locally_available_electricity 8.89 B Share
Reversed
17.0 %
83.0 %
Inputs Edges 52.32 B
100.0 %
Type MJ Node
Share 52.32 B environment_sun_solar_radiation
Edges 52.32 B Outputs
Node MJ Type
households_locally_available_electricity 8.89 B Share
Reversed
17.0 %
83.0 %
Inputs Edges 52.32 B
100.0 %
Type MJ Node
Share 52.32 B environment_sun_solar_radiation

Details

Sector households
Use energetic
Merit Order
group
dynamic: solar_pv
level
lv
subtype
volatile
type
producer
Node groups
  1. electricity_production
  2. primary_energy_demand
  3. sustainable_production
  4. volatile_production
  5. lv_net_supply
  6. wacc_households
  7. costs_building_and_installations_households
  8. preset_demand
Used in Gqueries
  1. costs_of_solar_pv_households_in_overview_costs_of_electricity_production
  2. depreciation_costs_households_solar_panels_per_kw
  3. electricity_curtailment_flexible_curve
  4. energy_curtailment_solar_pv_electricity_peak_capacity
  5. energy_mix_capacity_per_panel_solar_pv
  6. etflex_households_investment_per_household
  7. etflex_households_monthly_energy_bill
  8. etflex_households_renewability_percentage_electricity_per_household
  9. etmoses_number_of_solar_pv
  10. factsheet_number_of_roof_solar_pv
  11. factsheet_supply_electricity_from_roof_solar
  12. factsheet_supply_electricity_from_roof_solar_households
  13. households_potential_electricity_production_of_solar_roof_pv
  14. households_solar_pv_curtailed_electricity_output_curve
  15. households_solar_pv_electricity_output_curve
  16. households_solar_pv_installed_capacity
  17. households_solar_pv_production_after_curtailment
  18. households_solar_pv_production_before_curtailment
  19. households_solar_pv_solar_radiation
  20. households_solar_pv_solar_radiation_delta_in_investment_cost_table
  21. households_solar_pv_solar_radiation_future_in_investment_cost_table
  22. households_solar_pv_solar_radiation_present_in_investment_cost_table
  23. investment_for_solar_pv_households_in_overview_costs_of_electricity_production
  24. land_use_solar_wind_solar_pv_households_capacity_per_unit
  25. land_use_solar_wind_solar_pv_households_electricity_output
  26. land_use_solar_wind_solar_pv_households_full_load_hours
  27. land_use_solar_wind_solar_pv_households_installed_capacity
  28. land_use_solar_wind_solar_pv_households_land_use_per_unit
  29. land_use_solar_wind_solar_pv_households_number_of_units
  30. loss_of_load_expectation
  31. maximum_number_solar_pv_panels
  32. merit_order_households_solar_pv_solar_radiation_availability_in_merit_order_table
  33. merit_order_households_solar_pv_solar_radiation_capacity_factor_in_merit_order_table
  34. merit_order_households_solar_pv_solar_radiation_capacity_in_merit_order_table
  35. merit_order_households_solar_pv_solar_radiation_full_load_hours_in_merit_order_table
  36. merit_order_households_solar_pv_solar_radiation_load_factor_in_merit_order_table
  37. merit_order_households_solar_pv_solar_radiation_operating_costs_in_merit_order_table
  38. solar_panels_in_roof_area_for_pv_in_households
  39. solar_panels_in_source_of_electricity_in_households
  40. solar_pv_total_curtailed_electricity_curve
  41. solar_pv_total_curtailed_electricity_input_curve
  42. total_cost_of_households_solar_pv_solar_radiation
Used in Inputs
  1. capacity_of_households_solar_pv_solar_radiation
  2. curtailment_of_households_solar_pv_solar_radiation
  3. efficiency_energy_power_solar_pv_solar_radiation
  4. flh_of_solar_pv_solar_radiation
  5. flh_of_solar_pv_solar_radiation_user_curve
  6. investment_costs_solar_solar_panels
  7. settings_weather_curve_set
Method Label Present Future Unit
technical
electricity_output_capacity * number_of_units Installed electrical capacity 2,849.4 2,849.4 MW
electricity_output_capacity Capacity per unit 0 0 MW
electricity_output_conversion Electrical efficiency 17.0 17.0 %
full_load_hours Full load hours 867 867 hour / year
cost
total_investment_over_lifetime_per(:mw_electricity) Investment over lifetime per MW 1300000 1300000 EUR / MW
fixed_operation_and_maintenance_costs_per(:mw_electricity) Fixed operation and maintenance costs 16985 16985 EUR / MW / year
variable_operation_and_maintenance_costs_per_full_load_hour Variable operation and maintenance costs 0 0 EUR / full load hour
wacc Weighted average cost of capital 2.0 2.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
land_use_per_unit / electricity_output_capacity Land use 0.006 0.006 km2 / MW
technical_lifetime Technical lifetime 25 25 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 0 0 0% MWe
heat_output_capacity 0 0 MWth
hydrogen_output_capacity 0 0 MW
free_co2_factor 0 0
ccs_capture_rate - -
construction_time 0.3 0.3 0%
electrical_efficiency_when_using_coal - -
electrical_efficiency_when_using_wood_pellets - -
full_load_hours 867 867 0%
households_supplied_per_unit - -
land_use_per_unit 0 0 0%
takes_part_in_ets 0 0 yes=1 / no=0
technical_lifetime 25 25 0% year
typical_input_capacity - - MWinput
output_capacity - - MW
input_efficiency - -
output_efficiency - -
cost
initial_investment 217.3 217.3 0% euro / unit
ccs_investment 0 0 euro / unit
cost_of_installing 136.3 136.3 0% euro / unit
decommissioning_costs 0 0 euro / unit
fixed_operation_and_maintenance_costs_per_year 4.62 4.62 0% euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 0 0 euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 0 0 euro / full load hour
fixed_costs_per_mw_input_capacity - - euro / MWinput
costs_per_mj - -
wacc 0.02 0.02 0%
profitability - - profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity - - eur/MWh
marginal_costs 0 0 euro / MWh
max_consumption_price 0 0 euro / MWh
merit_order
merit_order_full_load_hours - -
merit_order_capacity_factor - -
merit_order_position - -
security_of_supply
availability 0.98 0.98 0%
part_load_operating_point - -
part_load_efficiency_penalty - -
forecasting_error - -
misc
demand_expected_value - -
excel_id - -
max_demand - -
Node Calculations Present Future Change Unit
demand
demand 52.32 B 52.32 B 0%
preset_demand 52.32 B 52.32 B 0%
demand_of_sustainable 0 0
weighted_carrier_cost_per_mj 0 0
weighted_carrier_co2_per_mj 0 0
sustainability_share 1 1 0%
final_demand 0 0
primary_demand 8.89 B 8.89 B 0%
primary_demand_of_fossil 0 0
primary_demand_of_sustainable 8.89 B 8.89 B 0%
primary_demand_of_electricity 8.89 B 8.89 B 0%
technical
input_capacity 0.002 0.002 0%
electric_based_input_capacity 0.002 0.002 0% MWinput
heat_based_input_capacity - - MWinput
cooling_based_input_capacity - - MWinput
number_of_units 10.48 M 10.48 M 0%
costs_per_plant
total_costs_per(:plant) 22.34 22.34 0% euro / plant
fixed_costs_per(:plant) 22.34 22.34 0%
cost_of_capital_per(:plant) 3.58 3.58 0%
depreciation_costs_per(:plant) 14.14 14.14 0%
variable_costs_per(:plant) 0 0
fuel_costs_per(:plant) 0 0
co2_emissions_costs_per(:plant) 0 0
captured_biogenic_co2_costs_per(:plant) 0 0
fixed_operation_and_maintenance_costs_per(:plant) 4.62 4.62 0%
variable_operation_and_maintenance_costs_per(:plant) 0 0
total_initial_investment_per(:plant) 353.6 353.6 0%
costs_per_node
total_costs_per(:node) 234.06 M 234.06 M 0%
fixed_costs_per(:node) 234.06 M 234.06 M 0%
cost_of_capital_per(:node) 37.49 M 37.49 M 0%
depreciation_costs_per(:node) 148.17 M 148.17 M 0%
variable_costs_per(:node) 0 0
fuel_costs_per(:node) 0 0
co2_emissions_costs_per(:node) 0 0
captured_biogenic_co2_costs_per(:node) 0 0
fixed_operation_and_maintenance_costs_per(:node) 48.4 M 48.4 M 0%
variable_operation_and_maintenance_costs_per(:node) 0 0
total_initial_investment_per(:node) 3.7 B 3.7 B 0%
costs_per_mw_electricity
total_costs_per(:mw_electricity) 82,141.3 82,141.3 0%
fixed_costs_per(:mw_electricity) 82,141.3 82,141.3 0%
cost_of_capital_per(:mw_electricity) 13,156 13,156 0%
depreciation_costs_per(:mw_electricity) 52,000 52,000 0%
variable_costs_per(:mw_electricity) 0 0
fuel_costs_per(:mw_electricity) 0 0
co2_emissions_costs_per(:mw_electricity) 0 0
captured_biogenic_co2_costs_per(:mw_electricity) 0 0
fixed_operation_and_maintenance_costs_per(:mw_electricity) 16,985.3 16,985.3 0%
variable_operation_and_maintenance_costs_per(:mw_electricity) 0 0
total_initial_investment_per(:mw_electricity) 1,300 K 1,300 K 0%
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 94.74 94.74 0%
fixed_costs_per(:mwh_electricity) 94.74 94.74 0%
cost_of_capital_per(:mwh_electricity) 15.17 15.17 0%
depreciation_costs_per(:mwh_electricity) 59.98 59.98 0%
variable_costs_per(:mwh_electricity) 0 0
fuel_costs_per(:mwh_electricity) 0 0
co2_emissions_costs_per(:mwh_electricity) 0 0
captured_biogenic_co2_costs_per(:mwh_electricity) 0 0
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 19.59 19.59 0%
variable_operation_and_maintenance_costs_per(:mwh_electricity) 0 0
total_initial_investment_per(:mwh_electricity) 1,499.4 1,499.4 0%
costs_per_mw_heat
total_costs_per(:mw_heat) 0 0
fixed_costs_per(:mw_heat) 0 0
cost_of_capital_per(:mw_heat) 0 0
depreciation_costs_per(:mw_heat) 0 0
variable_costs_per(:mw_heat) NaN NaN
fuel_costs_per(:mw_heat) NaN NaN
co2_emissions_costs_per(:mw_heat) NaN NaN
captured_biogenic_co2_costs_per(:mw_heat) NaN NaN
fixed_operation_and_maintenance_costs_per(:mw_heat) 0 0
variable_operation_and_maintenance_costs_per(:mw_heat) NaN NaN
total_initial_investment_per(:mw_heat) 0 0
costs_per_mwh_heat
total_costs_per(:mwh_heat) 0 0
fixed_costs_per(:mwh_heat) 0 0
cost_of_capital_per(:mwh_heat) 0 0
depreciation_costs_per(:mwh_heat) 0 0
variable_costs_per(:mwh_heat) NaN NaN
fuel_costs_per(:mwh_heat) NaN NaN
co2_emissions_costs_per(:mwh_heat) NaN NaN
captured_biogenic_co2_costs_per(:mwh_heat) NaN NaN
fixed_operation_and_maintenance_costs_per(:mwh_heat) 0 0
variable_operation_and_maintenance_costs_per(:mwh_heat) NaN NaN
total_initial_investment_per(:mwh_heat) 0 0