Present 206.32 M 206.32 M 206.32 M
Future 0 0 0
-100%
Edges 206.32 M Outputs
Node MJ Type
industry_locally_available_electricity 88.72 M Flexible
Reversed
43.0 %
10.0 %
Node MJ Type
industry_locally_available_steam_hot_water 96.97 M Flexible
Reversed
47.0 %
Inputs Edges 206.32 M
100.0 %
Type MJ Node
Share 206.32 M energy_mixer_for_gas_power_fuel
Edges 0 Outputs
Node MJ Type
industry_locally_available_electricity 0 Flexible
Reversed
43.0 %
10.0 %
Node MJ Type
industry_locally_available_steam_hot_water 0 Flexible
Reversed
47.0 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_mixer_for_gas_power_fuel

Details

Sector industry
Use energetic
Merit Order
level
mv
subtype
dispatchable
type
producer
Network Gas
demand_carrier
gas_power_fuelmix
profile
self: electricity_output_curve
type
consumer
Node groups
  1. preset_demand
  2. electricity_production
  3. dispatchable_production
  4. heat_production
  5. mv_net_supply
  6. wacc_proven_tech
  7. costs_production_chp_plants
  8. sankey_conversion_group
Used in Gqueries
  1. chp_electricity_in_source_of_heat_and_electricity_in_industry
  2. chp_heat_in_source_of_heat_and_electricity_in_industry
  3. costs_of_gas_chp_industry_in_overview_costs_of_electricity_production
  4. electricity_demand_in_industry_supplied_by_central_production
  5. factsheet_supply_heat_from_rest_and_geothermal
  6. fossil_electricity_from_chps_in_industry
  7. fossil_heat_from_chps_in_industry
  8. heat_demand_in_industry_not_supplied_by_chps
  9. heat_from_chp_in_use_of_final_demand_in_industry
  10. industry_chp_engine_gas_power_fuelmix
  11. industry_chp_engine_gas_power_fuelmix_capacity_in_chp_properties
  12. industry_chp_engine_gas_power_fuelmix_delta_in_investment_cost_table
  13. industry_chp_engine_gas_power_fuelmix_electricity_production_in_chp_properties
  14. industry_chp_engine_gas_power_fuelmix_future_in_investment_cost_table
  15. industry_chp_engine_gas_power_fuelmix_heat_production_in_chp_properties
  16. industry_chp_engine_gas_power_fuelmix_in_industrial_heat_network_mekko
  17. industry_chp_engine_gas_power_fuelmix_number_of_units_in_chp_properties
  18. industry_chp_engine_gas_power_fuelmix_present_in_investment_cost_table
  19. industry_fuelmix_network_gas_in_co2_sankey
  20. industry_fuelmix_oil_in_co2_sankey
  21. industry_fuelmix_total_in_co2_sankey
  22. investment_for_gas_chp_industry_in_overview_costs_of_electricity_production
  23. merit_order_industry_chp_gas_engine_availability_in_merit_order_table
  24. merit_order_industry_chp_gas_engine_capacity_in_merit_order_table
  25. merit_order_industry_chp_gas_engine_full_load_hours_in_merit_order_table
  26. merit_order_industry_chp_gas_engine_load_factor_in_merit_order_table
  27. merit_order_industry_chp_gas_engine_operating_costs_in_merit_order_table
  28. merit_order_industry_chp_gas_engine_position_in_merit_order_table
  29. renewable_electricity_from_chps_in_industry
  30. renewable_heat_from_chps_in_industry
  31. total_cost_of_industry_chp_engine_gas_power_fuelmix
Used in Inputs
  1. capacity_of_industry_chp_engine_gas_power_fuelmix
  2. efficiency_industry_chp_engine_gas_power_fuelmix_electricity
  3. efficiency_industry_chp_engine_gas_power_fuelmix_heat
  4. external_coupling_capacity_of_industry_chp_engine_gas_power_fuelmix
  5. external_coupling_efficiency_industry_chp_engine_gas_power_fuelmix_electricity
  6. external_coupling_efficiency_industry_chp_engine_gas_power_fuelmix_heat
  7. investment_costs_combustion_gas_plant
  8. om_costs_combustion_gas_plant
Method Label Present Future Unit
technical
electricity_output_capacity * number_of_units Installed electrical capacity 39.75 39.75 MW
electricity_output_conversion Electrical efficiency 43.0 43.0 %
heat_output_conversion Heat efficiency 47.0 47.0 %
full_load_hours Full load hours 620 0 hour / year
cost
total_investment_over_lifetime_per(:mw_electricity) Investment over lifetime per MW 581395 581395 EUR / MW
fixed_operation_and_maintenance_costs_per(:mw_electricity) Fixed operation and maintenance costs 0 0 EUR / MW / year
variable_operation_and_maintenance_costs_per_full_load_hour Variable operation and maintenance costs 8 8 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
technical_lifetime Technical lifetime 20 20 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 1.03 1.03 0% MWe
heat_output_capacity 1.13 1.13 0% MWth
hydrogen_output_capacity 0 0 MW
free_co2_factor 0 0
ccs_capture_rate - -
construction_time 1 1 0%
electrical_efficiency_when_using_coal - -
electrical_efficiency_when_using_wood_pellets - -
full_load_hours 620 0 -100%
households_supplied_per_unit - -
land_use_per_unit - -
takes_part_in_ets 0 0 yes=1 / no=0
technical_lifetime 20 20 0% year
typical_input_capacity 2.4 2.4 0% MWinput
output_capacity - - MW
input_efficiency - -
output_efficiency - -
cost
initial_investment 600 K 600 K 0% euro / unit
ccs_investment 0 0 euro / unit
cost_of_installing 0 0 euro / unit
decommissioning_costs 0 0 euro / unit
fixed_operation_and_maintenance_costs_per_year 0 0 euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 8 8 0% euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 0 0 euro / full load hour
fixed_costs_per_mw_input_capacity - - euro / MWinput
costs_per_mj - -
wacc 0.04 0.04 0%
profitability - profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity - - eur/MWh
marginal_costs 45.18 45.18 0% euro / MWh
max_consumption_price 45.18 45.18 0% euro / MWh
merit_order
merit_order_full_load_hours - -
merit_order_capacity_factor - -
merit_order_position - 14
security_of_supply
availability 0.95 0.95 0%
part_load_operating_point - -
part_load_efficiency_penalty - -
forecasting_error - -
misc
demand_expected_value - -
excel_id - -
max_demand - -
Node Calculations Present Future Change Unit
demand
demand 206.32 M 0 -100%
preset_demand 206.32 M 206.32 M 0%
demand_of_sustainable 0 0
weighted_carrier_cost_per_mj 0.004 0.004 0%
weighted_carrier_co2_per_mj 0.058 0.058 0%
sustainability_share 0.004 0.004 0%
final_demand 0 0
primary_demand 209.01 M 0 -100%
primary_demand_of_fossil 208.13 M 0 -100%
primary_demand_of_sustainable 881 K 0 -100%
primary_demand_of_crude_oil 16.45 M 0 -100%
primary_demand_of_biogas 874 K 0 -100%
primary_demand_of_lng 2,791 K 0 -100%
primary_demand_of_natural_gas 188.89 M 0 -100%
technical
input_capacity 2.4 2.4 0%
electric_based_input_capacity 2.4 2.4 0% MWinput
heat_based_input_capacity 2.4 2.4 0% MWinput
cooling_based_input_capacity - - MWinput
number_of_units 38.52 38.52 0%
costs_per_plant
total_costs_per(:plant) 71,510.5 42,600 -40% euro / plant
fixed_costs_per(:plant) 42,600 42,600 0%
cost_of_capital_per(:plant) 12,600 12,600 0%
depreciation_costs_per(:plant) 30,000 30,000 0%
variable_costs_per(:plant) 28,910.5 0 -100%
fuel_costs_per(:plant) 23,950.5 0 -100%
co2_emissions_costs_per(:plant) 0 0
captured_biogenic_co2_costs_per(:plant) 0 0
fixed_operation_and_maintenance_costs_per(:plant) 0 0
variable_operation_and_maintenance_costs_per(:plant) 4,960 0 -100%
total_initial_investment_per(:plant) 600 K 600 K 0%
costs_per_node
total_costs_per(:node) 2,754 K 1,641 K -40%
fixed_costs_per(:node) 1,641 K 1,641 K 0%
cost_of_capital_per(:node) 485 K 485 K 0%
depreciation_costs_per(:node) 1,155 K 1,155 K 0%
variable_costs_per(:node) 1,114 K 0 -100%
fuel_costs_per(:node) 922 K 0 -100%
co2_emissions_costs_per(:node) 0 0
captured_biogenic_co2_costs_per(:node) 0 0
fixed_operation_and_maintenance_costs_per(:node) 0 0
variable_operation_and_maintenance_costs_per(:node) 191 K 0 -100%
total_initial_investment_per(:node) 23.11 M 23.11 M 0%
costs_per_mw_electricity
total_costs_per(:mw_electricity) 69,293.1 41,279.1 -40%
fixed_costs_per(:mw_electricity) 41,279.1 41,279.1 0%
cost_of_capital_per(:mw_electricity) 12,209.3 12,209.3 0%
depreciation_costs_per(:mw_electricity) 29,069.8 29,069.8 0%
variable_costs_per(:mw_electricity) 28,014 0 -100%
fuel_costs_per(:mw_electricity) 23,207.8 0 -100%
co2_emissions_costs_per(:mw_electricity) 0 0
captured_biogenic_co2_costs_per(:mw_electricity) 0 0
fixed_operation_and_maintenance_costs_per(:mw_electricity) 0 0
variable_operation_and_maintenance_costs_per(:mw_electricity) 4,806.2 0 -100%
total_initial_investment_per(:mw_electricity) 581 K 581 K 0%
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 111.8 0 -100%
fixed_costs_per(:mwh_electricity) 66.58 0 -100%
cost_of_capital_per(:mwh_electricity) 19.69 0 -100%
depreciation_costs_per(:mwh_electricity) 46.89 0 -100%
variable_costs_per(:mwh_electricity) 45.18 NaN
fuel_costs_per(:mwh_electricity) 37.43 NaN
co2_emissions_costs_per(:mwh_electricity) 0 NaN
captured_biogenic_co2_costs_per(:mwh_electricity) 0 NaN
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 0 NaN
variable_operation_and_maintenance_costs_per(:mwh_electricity) 7.75 NaN
total_initial_investment_per(:mwh_electricity) 937.7 0 -100%
costs_per_mw_heat
total_costs_per(:mw_heat) 63,395.8 37,766 -40%
fixed_costs_per(:mw_heat) 37,766 37,766 0%
cost_of_capital_per(:mw_heat) 11,170.2 11,170.2 0%
depreciation_costs_per(:mw_heat) 26,595.7 26,595.7 0%
variable_costs_per(:mw_heat) 25,629.9 0 -100%
fuel_costs_per(:mw_heat) 21,232.7 0 -100%
co2_emissions_costs_per(:mw_heat) 0 0
captured_biogenic_co2_costs_per(:mw_heat) 0 0
fixed_operation_and_maintenance_costs_per(:mw_heat) 0 0
variable_operation_and_maintenance_costs_per(:mw_heat) 4,397.2 0 -100%
total_initial_investment_per(:mw_heat) 532 K 532 K 0%
costs_per_mwh_heat
total_costs_per(:mwh_heat) 102.3 0 -100%
fixed_costs_per(:mwh_heat) 60.91 0 -100%
cost_of_capital_per(:mwh_heat) 18.02 0 -100%
depreciation_costs_per(:mwh_heat) 42.9 0 -100%
variable_costs_per(:mwh_heat) 41.34 NaN
fuel_costs_per(:mwh_heat) 34.25 NaN
co2_emissions_costs_per(:mwh_heat) 0 NaN
captured_biogenic_co2_costs_per(:mwh_heat) 0 NaN
fixed_operation_and_maintenance_costs_per(:mwh_heat) 0 NaN
variable_operation_and_maintenance_costs_per(:mwh_heat) 7.09 NaN
total_initial_investment_per(:mwh_heat) 857.9 0 -100%