GQL Statement

DIVIDE(
  SUM(
    V(
      G(heat_production),
      "steam_hot_water_output_conversion / (1 - loss_output_conversion) * input_of_wood_pellets"
    )
  ), 
  BILLIONS
)

Result

2019 3.9 ms
13.416318895273067
PJ
2050 3.67 ms
5.689644240754338
PJ

Description

Direct conversion input of wood pellets for central electricity production

Characteristics

Groups
Unit PJ
File path /app/tmp/etsource/gqueries/general/conversion/heat/conversion_from_carrier_to_heat/conversion_from_wood_pellets_to_heat.gql

References

Gquery conversion_from_biomass_products_to_heat