Present 0 0 0
Future 0 0 0
Edges 0 Outputs
80.0 %
20.0 %
Inputs Edges 0
100.0 %
Type MJ Node
Flexible 0 energy_production_excess_electricity
Edges 0 Outputs
0.0 %
100.0 %
Inputs Edges 0
100.0 %
Type MJ Node
Flexible 0 energy_production_excess_electricity

Details

Sector energy
Use energetic
Merit Order
level
hv
subtype
storage
type
flex
Storage
cost_per_mwh
470000.0
decay
0.0
volume
3000.0
Node groups
  1. hv_net_flexibility
  2. p2p
  3. wacc_proven_tech
  4. costs_storage_and_conversion_p2p
  5. sankey_conversion_group
Used in Gqueries
  1. electricity_demand_flexible_storage_capacity
  2. electricity_production_flexible_storage_capacity
  3. electricity_stored_in_pumped_storage
  4. energy_flexibility_pumped_storage_efficiency
  5. energy_flexibility_pumped_storage_electricity
  6. energy_flexibility_pumped_storage_electricity_capacity
  7. energy_flexibility_pumped_storage_electricity_flhs
  8. energy_flexibility_pumped_storage_electricity_input
  9. energy_flexibility_pumped_storage_electricity_input_curve
  10. energy_flexibility_pumped_storage_electricity_losses
  11. energy_flexibility_pumped_storage_electricity_output
  12. energy_flexibility_pumped_storage_electricity_peak_capacity
  13. energy_flexibility_pumped_storage_electricity_storage_curve
  14. energy_flexibility_pumped_storage_electricity_volume
  15. energy_flexibility_pumped_storage_output_capacity
  16. energy_flexibility_pumped_storage_peak_output_capacity
  17. energy_flexibility_pumped_storage_volume_to_capacity_ratio
  18. excess_event_excludes
  19. user_sortable_energy_flexibility_pumped_storage_electricity_capacity
  20. user_sortable_energy_flexibility_pumped_storage_electricity_is_sortable
Used in Inputs
  1. capacity_of_energy_flexibility_pumped_storage_electricity
  2. efficiency_energy_flexibility_pumped_storage_electricity
  3. settings_enable_storage_optimisation_energy_flexibility_pumped_storage_electricity
  4. volume_of_energy_flexibility_pumped_storage_electricity
  5. wta_of_energy_flexibility_pumped_storage_electricity
  6. wtp_of_energy_flexibility_pumped_storage_electricity
Method Label Present Future Unit
technical
input_capacity * number_of_units Installed capacity 0 0 MW
storage[:volume] * number_of_units Total storage capacity 0 0 MWh
1.0/electricity_input_conversion * electricity_output_conversion Round trip efficiency 80.0 0.0 %
cost
total_investment_over_lifetime_per(:mw_input_capacity) Investment over lifetime per MW input 2820000 2820000 EUR / MW
fixed_operation_and_maintenance_costs_per(:mw_input_capacity) Fixed operation and maintenance costs 28000 28000 EUR / MW / year
variable_operation_and_maintenance_costs_per_full_load_hour Variable operation and maintenance costs 0 0 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
technical_lifetime Technical lifetime 75 75 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 500 500 0% MWe
heat_output_capacity 0 0 MWth
hydrogen_output_capacity 0 0 MW
free_co2_factor 0 0
ccs_capture_rate - -
construction_time 5 5 0%
electrical_efficiency_when_using_coal - -
electrical_efficiency_when_using_wood_pellets - -
full_load_hours 0 0
households_supplied_per_unit - -
land_use_per_unit - -
takes_part_in_ets 0 0 yes=1 / no=0
technical_lifetime 75 75 0% year
typical_input_capacity 500 500 0% MWinput
output_capacity - - MW
input_efficiency - -
output_efficiency - -
cost
initial_investment 0 0 euro / unit
ccs_investment 0 0 euro / unit
cost_of_installing 0 0 euro / unit
decommissioning_costs 0 0 euro / unit
fixed_operation_and_maintenance_costs_per_year 14 M 14 M 0% euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 0 0 euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 0 0 euro / full load hour
fixed_costs_per_mw_input_capacity 0 0 euro / MWinput
costs_per_mj - -
wacc 0.04 0.04 0%
profitability - - profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity - - eur/MWh
marginal_costs 5.5 5.5 0% euro / MWh
max_consumption_price 4.4 4.4 0% euro / MWh
merit_order
merit_order_full_load_hours - -
merit_order_capacity_factor - -
merit_order_position - -
security_of_supply
availability 0.95 0.95 0%
part_load_operating_point - -
part_load_efficiency_penalty - -
forecasting_error - -
misc
demand_expected_value 0 0
excel_id - -
max_demand - -
Node Calculations Present Future Change Unit
demand
demand 0 0
preset_demand - -
demand_of_sustainable 0 0
weighted_carrier_cost_per_mj 0 0
weighted_carrier_co2_per_mj 0 0
sustainability_share 1 1 0%
final_demand 0 0
primary_demand 0 0
primary_demand_of_fossil 0 0
primary_demand_of_sustainable 0 0
technical
input_capacity 500 500 0%
electric_based_input_capacity 625 - MWinput
heat_based_input_capacity - - MWinput
cooling_based_input_capacity - - MWinput
number_of_units 0 0
costs_per_plant
total_costs_per(:plant) 62.88 M 62.88 M 0% euro / plant
fixed_costs_per(:plant) 62.88 M 62.88 M 0%
cost_of_capital_per(:plant) 30.08 M 30.08 M 0%
depreciation_costs_per(:plant) 18.8 M 18.8 M 0%
variable_costs_per(:plant) 0 0
fuel_costs_per(:plant) 0 0
co2_emissions_costs_per(:plant) 0 0
captured_biogenic_co2_costs_per(:plant) 0 0
fixed_operation_and_maintenance_costs_per(:plant) 14 M 14 M 0%
variable_operation_and_maintenance_costs_per(:plant) 0 0
total_initial_investment_per(:plant) 1.41 B 1.41 B 0%
costs_per_node
total_costs_per(:node) 0 0
fixed_costs_per(:node) 0 0
cost_of_capital_per(:node) 0 0
depreciation_costs_per(:node) 0 0
variable_costs_per(:node) 0 0
fuel_costs_per(:node) 0 0
co2_emissions_costs_per(:node) 0 0
captured_biogenic_co2_costs_per(:node) 0 0
fixed_operation_and_maintenance_costs_per(:node) 0 0
variable_operation_and_maintenance_costs_per(:node) 0 0
total_initial_investment_per(:node) 0 0
costs_per_mw_electricity
total_costs_per(:mw_electricity) 126 K 126 K 0%
fixed_costs_per(:mw_electricity) 126 K 126 K 0%
cost_of_capital_per(:mw_electricity) 60,160 60,160 0%
depreciation_costs_per(:mw_electricity) 37,600 37,600 0%
variable_costs_per(:mw_electricity) 0 0
fuel_costs_per(:mw_electricity) 0 0
co2_emissions_costs_per(:mw_electricity) 0 0
captured_biogenic_co2_costs_per(:mw_electricity) 0 0
fixed_operation_and_maintenance_costs_per(:mw_electricity) 28,000 28,000 0%
variable_operation_and_maintenance_costs_per(:mw_electricity) 0 0
total_initial_investment_per(:mw_electricity) 2,820 K 2,820 K 0%
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 0 0
fixed_costs_per(:mwh_electricity) 0 0
cost_of_capital_per(:mwh_electricity) 0 0
depreciation_costs_per(:mwh_electricity) 0 0
variable_costs_per(:mwh_electricity) NaN NaN
fuel_costs_per(:mwh_electricity) NaN NaN
co2_emissions_costs_per(:mwh_electricity) NaN NaN
captured_biogenic_co2_costs_per(:mwh_electricity) NaN NaN
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 0 0
variable_operation_and_maintenance_costs_per(:mwh_electricity) NaN NaN
total_initial_investment_per(:mwh_electricity) 0 0
costs_per_mw_heat
total_costs_per(:mw_heat) 0 0
fixed_costs_per(:mw_heat) 0 0
cost_of_capital_per(:mw_heat) 0 0
depreciation_costs_per(:mw_heat) 0 0
variable_costs_per(:mw_heat) NaN NaN
fuel_costs_per(:mw_heat) NaN NaN
co2_emissions_costs_per(:mw_heat) NaN NaN
captured_biogenic_co2_costs_per(:mw_heat) NaN NaN
fixed_operation_and_maintenance_costs_per(:mw_heat) 0 0
variable_operation_and_maintenance_costs_per(:mw_heat) NaN NaN
total_initial_investment_per(:mw_heat) 0 0
costs_per_mwh_heat
total_costs_per(:mwh_heat) 0 0
fixed_costs_per(:mwh_heat) 0 0
cost_of_capital_per(:mwh_heat) 0 0
depreciation_costs_per(:mwh_heat) 0 0
variable_costs_per(:mwh_heat) NaN NaN
fuel_costs_per(:mwh_heat) NaN NaN
co2_emissions_costs_per(:mwh_heat) NaN NaN
captured_biogenic_co2_costs_per(:mwh_heat) NaN NaN
fixed_operation_and_maintenance_costs_per(:mwh_heat) 0 0
variable_operation_and_maintenance_costs_per(:mwh_heat) NaN NaN
total_initial_investment_per(:mwh_heat) 0 0