GQL Statement
SUM(
MAX(
V(
FILTER(
ALL(),
"heat_network_ht && (heat_network_ht.subtype == :heat_storage)"
),
steam_hot_water_output_curve
)
),
MAX(
V(
FILTER(
ALL(),
"heat_network_mt && (heat_network_mt.subtype == :heat_storage)"
),
steam_hot_water_output_curve
)
),
MAX(
V(
FILTER(
ALL(),
"heat_network_lt && (heat_network_lt.subtype == :heat_storage)"
),
steam_hot_water_output_curve
)
)
)
Result
2019
77.23
ms
|
0
|
MW |
2050
34.2
ms
|
0.0
|
MW |
Description
Selects the heat output capacity of the heat storage by taking the maximum value of the hourly output curve.
Characteristics
Groups |
|
Unit |
MW |
File path |
/app/tmp/etsource/gqueries/general/flexibility/heat_network/heat_network_production_flexible_storage_capacity.gql
|
References