GQL Statement

IF(
  V(households_water_heater_hybrid_heatpump_air_water_electricity, electricity_input_conversion) == 0.0,
  1.0,
  DIVIDE(
    V(
      households_water_heater_hybrid_heatpump_air_water_electricity,
      "ambient_heat_input_conversion + electricity_input_conversion"
    ),
    V(households_water_heater_hybrid_heatpump_air_water_electricity, electricity_input_conversion)
  )
)

Result

2019 0.29 ms
3.999999999999995
COP
2050 0.05 ms
1.0
COP

Description

Characteristics

Groups
Unit COP
File path /app/tmp/etsource/gqueries/general/heat/cop_manual_calculation/households_water_heater_hybrid_heatpump_air_water_electricity_cop_manual_calculation.gql

References