GQL Statement
IF(
V(households_water_heater_hybrid_heatpump_air_water_electricity, electricity_input_conversion) == 0.0,
1.0,
DIVIDE(
V(
households_water_heater_hybrid_heatpump_air_water_electricity,
"ambient_heat_input_conversion + electricity_input_conversion"
),
V(households_water_heater_hybrid_heatpump_air_water_electricity, electricity_input_conversion)
)
)
Result
2019
0.29
ms
|
3.999999999999995
|
COP |
2050
0.05
ms
|
1.0
|
COP |
Description
Characteristics
Groups |
|
Unit |
COP |
File path |
/app/tmp/etsource/gqueries/general/heat/cop_manual_calculation/households_water_heater_hybrid_heatpump_air_water_electricity_cop_manual_calculation.gql
|
References