energy_chp_supercritical_ccs_ht_waste_mix
Present
0
0
0
Future
0
0
0
|
|
|
|
Details
Node Summary
| Method | Label | Present | Future | Unit |
|---|---|---|---|---|
| technical | ||||
| electricity_output_capacity * number_of_units | Installed electrical capacity | 0 | 0 | MW |
| electricity_output_conversion | Electrical efficiency | 20.4 | 20.4 | % |
| full_load_hours | Full load hours | 4,390 | 0 | hour / year |
| cost | ||||
| initial_investment_per(:mw_electricity) + cost_of_installing_per(:mw_electricity) + decommissioning_costs_per(:mw_electricity) | Investment over lifetime per MW | 2796244 | 2796244 | EUR / MW |
| ccs_investment_per(:mw_electricity) | Additional initial investment for CCS | 1190992 | 1190992 | EUR / MW |
| fixed_operation_and_maintenance_costs_per(:mw_electricity) | Fixed operation and maintenance costs | 82851 | 82851 | EUR / MW / year |
| variable_operation_and_maintenance_costs_per_full_load_hour | Variable operation and maintenance costs (excl CCS) | 0 | 0 | EUR / full load hour |
| variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour | Additional variable operation and maintenance costs for CCS | 0 | 0 | EUR / full load hour |
| wacc | Weighted average cost of capital | 4.0 | 4.0 | % |
| takes_part_in_ets | Do emissions have to be paid through the ETS? | true | true | boolean |
| other | ||||
| technical_lifetime | Technical lifetime | 30 | 30 | years |
All Attributes
| Node Attributes | Present | Future | Change | Unit |
|---|---|---|---|---|
| operational | ||||
| electricity_output_capacity | 57.93 | 57.93 | {:class=>"change"} | MWe |
| heat_output_capacity | 56.52 | 56.52 | {:class=>"change"} | MWth |
| hydrogen_output_capacity | 0 | 0 | {:class=>"change"} | MW |
| free_co2_factor | 0.85 | 0.85 | {:class=>"change"} | |
| ccs_capture_rate | 0.85 | 0.85 | {:class=>"change"} | |
| construction_time | 3.5 | 3.5 | {:class=>"change"} | |
| electrical_efficiency_when_using_coal | - | - | {:class=>"change"} | |
| electrical_efficiency_when_using_wood_pellets | - | - | {:class=>"change"} | |
| full_load_hours | 4,390 | 0 | {:class=>"change"} | |
| households_supplied_per_unit | - | - | {:class=>"change"} | |
| land_use_per_unit | - | - | {:class=>"change"} | |
| takes_part_in_ets | 1 | 1 | {:class=>"change"} | yes=1 / no=0 |
| technical_lifetime | 30 | 30 | {:class=>"change"} | year |
| typical_input_capacity | 283.3 | 283.3 | {:class=>"change"} | MWinput |
| output_capacity | - | - | {:class=>"change"} | MW |
| input_efficiency | - | - | {:class=>"change"} | |
| output_efficiency | - | - | {:class=>"change"} | |
| cost | ||||
| initial_investment | 162 M | 162 M | {:class=>"change"} | euro / unit |
| ccs_investment | 69 M | 69 M | {:class=>"change"} | euro / unit |
| cost_of_installing | 0 | 0 | {:class=>"change"} | euro / unit |
| decommissioning_costs | 0 | 0 | {:class=>"change"} | euro / unit |
| fixed_operation_and_maintenance_costs_per_year | 4,800 K | 4,800 K | {:class=>"change"} | euro / unit / year |
| variable_operation_and_maintenance_costs_per_full_load_hour | 0 | 0 | {:class=>"change"} | euro / full load hour |
| variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour | 0 | 0 | {:class=>"change"} | euro / full load hour |
| fixed_costs_per_mw_input_capacity | - | - | {:class=>"change"} | euro / MWinput |
| costs_per_mj | - | - | {:class=>"change"} | |
| wacc | 0.04 | 0.04 | {:class=>"change"} | |
| profitability | - | unprofitable | {:class=>"change"} | profitable / unprofitable / conditionally_profitable |
| profit_per_mwh_electricity | - | - | {:class=>"change"} | eur/MWh |
| marginal_costs | 0 | 0 | {:class=>"change"} | euro / MWh |
| max_consumption_price | 0 | 0 | {:class=>"change"} | euro / MWh |
| capital_expenditures | 12.86 M | 12.86 M | {:class=>"change"} | euro / unit / year |
| operating_expenses | 4,800 K | 4,800 K | {:class=>"change"} | euro / unit / year |
| operating_expenses_including_fuel | 2,515 K | 4,800 K | {:class=>"change"} | euro / unit / year |
| revenue | 0 | 0 | {:class=>"change"} | euro / unit / year |
| merit_order | ||||
| merit_order_full_load_hours | - | - | {:class=>"change"} | |
| merit_order_capacity_factor | - | - | {:class=>"change"} | |
| merit_order_position | - | - | {:class=>"change"} | |
| security_of_supply | ||||
| availability | 0.9 | 0.9 | {:class=>"change"} | |
| part_load_operating_point | - | - | {:class=>"change"} | |
| part_load_efficiency_penalty | - | - | {:class=>"change"} | |
| forecasting_error | - | - | {:class=>"change"} | |
| misc | ||||
| demand_expected_value | - | - | {:class=>"change"} | |
| excel_id | - | - | {:class=>"change"} | |
| max_demand | - | - | {:class=>"change"} | |