Present 0 0 0
Future 0 0 0
Edges 0 Outputs
Node MJ Type
energy_power_hv_network_electricity 0 Flexible
Reversed
60.0 %
40.0 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_national_gas_network_natural_gas
Edges 0 Outputs
Node MJ Type
energy_power_hv_network_electricity 0 Flexible
Reversed
60.0 %
40.0 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_national_gas_network_natural_gas

Details

Sector energy
Use undefined
Merit Order
group
flat
level
hv
subtype
must_run
type
producer
Network Gas
profile
self: electricity_output_curve
type
consumer
Node groups
  1. preset_demand
  2. central_production
  3. electricity_production
  4. must_run_electricity_production
  5. hv_net_supply
  6. wacc_proven_tech
  7. costs_production_power_plants
  8. sankey_conversion_group
Used in Gqueries
  1. costs_of_gas_ccgt_must_run_in_overview_costs_of_electricity_production
  2. energy_power_combined_cycle_network_gas_must_run
  3. energy_power_combined_cycle_network_gas_must_run_delta_in_investment_cost_table
  4. energy_power_combined_cycle_network_gas_must_run_future_in_investment_cost_table
  5. energy_power_combined_cycle_network_gas_must_run_present_in_investment_cost_table
  6. gas_ccgt_must_run_capacity_in_power_plant_economic_performance_table
  7. gas_ccgt_must_run_capex_in_power_plant_economic_performance_table
  8. gas_ccgt_must_run_full_load_hours_in_power_plant_economic_performance_table
  9. gas_ccgt_must_run_opex_in_power_plant_economic_performance_table
  10. gas_ccgt_must_run_position_in_power_plant_economic_performance_table
  11. gas_ccgt_must_run_profit_in_power_plant_economic_performance_table
  12. gas_ccgt_must_run_revenue_in_power_plant_economic_performance_table
  13. investment_for_gas_ccgt_must_run_in_overview_costs_of_electricity_production
  14. merit_order_gas_ccgt_must_run_availability_in_merit_order_table
  15. merit_order_gas_ccgt_must_run_capacity_in_merit_order_table
  16. merit_order_gas_ccgt_must_run_full_load_hours_in_merit_order_table
  17. merit_order_gas_ccgt_must_run_load_factor_in_merit_order_table
  18. merit_order_gas_ccgt_must_run_operating_costs_in_merit_order_table
  19. merit_order_gas_ccgt_must_run_position_in_merit_order_table
Used in Inputs
  1. capacity_of_energy_power_combined_cycle_network_gas_must_run
  2. efficiency_energy_power_combined_cycle_network_gas
Method Label Present Future Unit
technical
electricity_output_capacity * number_of_units Installed electrical capacity 0 0 MW
electricity_output_conversion Electrical efficiency 60.0 60.0 %
full_load_hours Full load hours 4,370 4,370 hour / year
cost
total_investment_over_lifetime_per(:mw_electricity) Investment over lifetime per MW 749425 749425 EUR / MW
fixed_operation_and_maintenance_costs_per(:mw_electricity) Fixed operation and maintenance costs 11333 11333 EUR / MW / year
variable_operation_and_maintenance_costs_per_full_load_hour Variable operation and maintenance costs 1287 1287 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? true true boolean
other
technical_lifetime Technical lifetime 30 30 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 800800{class: "change"}MWe
heat_output_capacity 00{class: "change"}MWth
hydrogen_output_capacity 00{class: "change"}MW
free_co2_factor 00{class: "change"}
ccs_capture_rate --{class: "change"}
construction_time 2.52.5{class: "change"}
electrical_efficiency_when_using_coal --{class: "change"}
electrical_efficiency_when_using_wood_pellets --{class: "change"}
full_load_hours 4,3704,370{class: "change"}
households_supplied_per_unit --{class: "change"}
land_use_per_unit --{class: "change"}
takes_part_in_ets 11{class: "change"}yes=1 / no=0
technical_lifetime 3030{class: "change"}year
typical_input_capacity --{class: "change"}MWinput
output_capacity --{class: "change"}MW
input_efficiency --{class: "change"}
output_efficiency --{class: "change"}
cost
initial_investment 599.54 M599.54 M{class: "change"}euro / unit
ccs_investment 00{class: "change"}euro / unit
cost_of_installing 00{class: "change"}euro / unit
decommissioning_costs 00{class: "change"}euro / unit
fixed_operation_and_maintenance_costs_per_year 9,067 K9,067 K{class: "change"}euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 1,2871,287{class: "change"}euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 00{class: "change"}euro / full load hour
fixed_costs_per_mw_input_capacity --{class: "change"}euro / MWinput
costs_per_mj --{class: "change"}
wacc 0.040.04{class: "change"}
profitability --{class: "change"}profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity --{class: "change"}eur/MWh
marginal_costs 30.3530.35{class: "change"}euro / MWh
max_consumption_price 30.3530.35{class: "change"}euro / MWh
capital_expenditures 32.97 M32.97 M{class: "change"}euro / unit / year
operating_expenses 14.69 M14.69 M{class: "change"}euro / unit / year
operating_expenses_including_fuel 115.16 M115.16 M{class: "change"}euro / unit / year
revenue 00{class: "change"}euro / unit / year
merit_order
merit_order_full_load_hours --{class: "change"}
merit_order_capacity_factor --{class: "change"}
merit_order_position --{class: "change"}
security_of_supply
availability 0.90.9{class: "change"}
part_load_operating_point --{class: "change"}
part_load_efficiency_penalty --{class: "change"}
forecasting_error --{class: "change"}
misc
demand_expected_value --{class: "change"}
excel_id --{class: "change"}
max_demand --{class: "change"}
Node Calculations Present Future Change Unit
demand
demand 00{class: "change"}
preset_demand 00{class: "change"}
demand_of_sustainable 00{class: "change"}
weighted_carrier_cost_per_mj 0.0040.004{class: "change"}
weighted_carrier_co2_per_mj 0.0560.056{class: "change"}
sustainability_share 0.0050.005{class: "change"}
primary_demand 00{class: "change"}
primary_demand_of_fossil 00{class: "change"}
primary_demand_of_sustainable 00{class: "change"}
technical
input_capacity 1,333.31,333.3{class: "change"}
electric_based_input_capacity 1,333.31,333.3{class: "change"}MWinput
heat_based_input_capacity --{class: "change"}MWinput
cooling_based_input_capacity --{class: "change"}MWinput
number_of_units 00{class: "change"}
costs_per_plant
total_costs_per(:plant) 148.14 M148.14 M{class: "change"}euro / plant
fixed_costs_per(:plant) 42.04 M42.04 M{class: "change"}
cost_of_capital_per(:plant) 12.99 M12.99 M{class: "change"}
depreciation_costs_per(:plant) 19.98 M19.98 M{class: "change"}
variable_costs_per(:plant) 106.1 M106.1 M{class: "change"}
fuel_costs_per(:plant) 82.9 M82.9 M{class: "change"}
co2_emissions_costs_per(:plant) 17.58 M17.58 M{class: "change"}
captured_biogenic_co2_costs_per(:plant) 00{class: "change"}
fixed_operation_and_maintenance_costs_per(:plant) 9,067 K9,067 K{class: "change"}
variable_operation_and_maintenance_costs_per(:plant) 5,624 K5,624 K{class: "change"}
total_initial_investment_per(:plant) 599.54 M599.54 M{class: "change"}
costs_per_node
total_costs_per(:node) 00{class: "change"}
fixed_costs_per(:node) 00{class: "change"}
cost_of_capital_per(:node) 00{class: "change"}
depreciation_costs_per(:node) 00{class: "change"}
variable_costs_per(:node) 00{class: "change"}
fuel_costs_per(:node) 00{class: "change"}
co2_emissions_costs_per(:node) 00{class: "change"}
captured_biogenic_co2_costs_per(:node) 00{class: "change"}
fixed_operation_and_maintenance_costs_per(:node) 00{class: "change"}
variable_operation_and_maintenance_costs_per(:node) 00{class: "change"}
total_initial_investment_per(:node) 00{class: "change"}
costs_per_mw_electricity
total_costs_per(:mw_electricity) 185 K185 K{class: "change"}
fixed_costs_per(:mw_electricity) 52,551.752,551.7{class: "change"}
cost_of_capital_per(:mw_electricity) 16,237.516,237.5{class: "change"}
depreciation_costs_per(:mw_electricity) 24,980.824,980.8{class: "change"}
variable_costs_per(:mw_electricity) 133 K133 K{class: "change"}
fuel_costs_per(:mw_electricity) 104 K104 K{class: "change"}
co2_emissions_costs_per(:mw_electricity) 21,969.321,969.3{class: "change"}
captured_biogenic_co2_costs_per(:mw_electricity) 00{class: "change"}
fixed_operation_and_maintenance_costs_per(:mw_electricity) 11,333.311,333.3{class: "change"}
variable_operation_and_maintenance_costs_per(:mw_electricity) 7,030.27,030.2{class: "change"}
total_initial_investment_per(:mw_electricity) 749 K749 K{class: "change"}
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 42.3742.37{class: "change"}
fixed_costs_per(:mwh_electricity) 12.0312.03{class: "change"}
cost_of_capital_per(:mwh_electricity) 3.723.72{class: "change"}
depreciation_costs_per(:mwh_electricity) 5.725.72{class: "change"}
variable_costs_per(:mwh_electricity) 30.3530.35{class: "change"}
fuel_costs_per(:mwh_electricity) 23.7123.71{class: "change"}
co2_emissions_costs_per(:mwh_electricity) 5.035.03{class: "change"}
captured_biogenic_co2_costs_per(:mwh_electricity) 00{class: "change"}
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 2.592.59{class: "change"}
variable_operation_and_maintenance_costs_per(:mwh_electricity) 1.611.61{class: "change"}
total_initial_investment_per(:mwh_electricity) 171.5171.5{class: "change"}
costs_per_mw_heat
total_costs_per(:mw_heat) 00{class: "change"}
fixed_costs_per(:mw_heat) 00{class: "change"}
cost_of_capital_per(:mw_heat) 00{class: "change"}
depreciation_costs_per(:mw_heat) 00{class: "change"}
variable_costs_per(:mw_heat) 00{class: "change"}
fuel_costs_per(:mw_heat) 00{class: "change"}
co2_emissions_costs_per(:mw_heat) 00{class: "change"}
captured_biogenic_co2_costs_per(:mw_heat) NaNNaN{class: "change"}
fixed_operation_and_maintenance_costs_per(:mw_heat) 00{class: "change"}
variable_operation_and_maintenance_costs_per(:mw_heat) 00{class: "change"}
total_initial_investment_per(:mw_heat) 00{class: "change"}
costs_per_mwh_heat
total_costs_per(:mwh_heat) 00{class: "change"}
fixed_costs_per(:mwh_heat) 00{class: "change"}
cost_of_capital_per(:mwh_heat) 00{class: "change"}
depreciation_costs_per(:mwh_heat) 00{class: "change"}
variable_costs_per(:mwh_heat) 00{class: "change"}
fuel_costs_per(:mwh_heat) 00{class: "change"}
co2_emissions_costs_per(:mwh_heat) 00{class: "change"}
captured_biogenic_co2_costs_per(:mwh_heat) NaNNaN{class: "change"}
fixed_operation_and_maintenance_costs_per(:mwh_heat) 00{class: "change"}
variable_operation_and_maintenance_costs_per(:mwh_heat) 00{class: "change"}
total_initial_investment_per(:mwh_heat) 00{class: "change"}