Present 5.81 B 5.81 B 5.81 B
Future 5.81 B 5.81 B 5.81 B
Edges 5.81 B Outputs
Node MJ Type
agriculture_useful_demand_useable_heat 5.81 B Share
100.0 %
Inputs Edges 5.81 B
4.17 %
Type MJ Node
Share 241.91 M agriculture_final_demand_electricity
95.83 %
Type MJ Node
Share 5.56 B environment_earth_geothermal
Edges 5.81 B Outputs
Node MJ Type
agriculture_useful_demand_useable_heat 5.81 B Share
100.0 %
Inputs Edges 5.81 B
4.17 %
Type MJ Node
Share 241.91 M agriculture_final_demand_electricity
95.83 %
Type MJ Node
Share 5.56 B environment_earth_geothermal

Details

Sector agriculture
Use energetic
Merit Order
group
weather/agriculture_heating
level
mv
subtype
generic
type
consumer
Node groups
  1. heat_production
  2. application_group
  3. wacc_proven_tech
  4. costs_building_and_installations_agriculture
Used in Gqueries
  1. agriculture_geothermal_delta_in_investment_cost_table
  2. agriculture_geothermal_future_in_investment_cost_table
  3. agriculture_geothermal_present_in_investment_cost_table
  4. geothermal_own_use_in_sectors
  5. mv_agriculture_load_curve
  6. total_cost_of_agriculture_geothermal
Used in Inputs
  1. agriculture_geothermal_share
  2. flh_of_geothermal_heat_deep_user_curve
  3. flh_of_geothermal_heat_shallow_user_curve
  4. investment_costs_geothermal
  5. om_costs_geothermal
Method Label Present Future Unit
technical
coefficient_of_performance Coefficient of Performance 24 24 COP
heat_output_capacity Heat capacity per unit 14.0 14.0 MW / unit
full_load_hours Full load hours 6,000 6,000 hour / year
cost
total_investment_over_lifetime_per(:plant) Investment over lifetime per plant 26.73 M 26.73 M EUR / unit
fixed_operation_and_maintenance_costs_per(:plant) Fixed operation and maintenance costs 1,414 K 1,414 K EUR / unit / year
variable_operation_and_maintenance_costs_per(:full_load_hour) Variable operation and maintenance costs 26.6 26.6 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
technical_lifetime Technical lifetime 30 30 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 00{class: "change"}MWe
heat_output_capacity 1414{class: "change"}MWth
hydrogen_output_capacity 00{class: "change"}MW
free_co2_factor 00{class: "change"}
ccs_capture_rate --{class: "change"}
construction_time 00{class: "change"}
electrical_efficiency_when_using_coal --{class: "change"}
electrical_efficiency_when_using_wood_pellets --{class: "change"}
full_load_hours 6,0006,000{class: "change"}
households_supplied_per_unit --{class: "change"}
land_use_per_unit 00{class: "change"}
takes_part_in_ets 00{class: "change"}yes=1 / no=0
technical_lifetime 3030{class: "change"}year
typical_input_capacity --{class: "change"}MWinput
output_capacity --{class: "change"}MW
input_efficiency --{class: "change"}
output_efficiency --{class: "change"}
cost
initial_investment 26.73 M26.73 M{class: "change"}euro / unit
ccs_investment 00{class: "change"}euro / unit
cost_of_installing 00{class: "change"}euro / unit
decommissioning_costs 00{class: "change"}euro / unit
fixed_operation_and_maintenance_costs_per_year 1,414 K1,414 K{class: "change"}euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 26.626.6{class: "change"}euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 00{class: "change"}euro / full load hour
fixed_costs_per_mw_input_capacity --{class: "change"}euro / MWinput
costs_per_mj --{class: "change"}
wacc 0.040.04{class: "change"}
profitability --{class: "change"}profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity --{class: "change"}eur/MWh
marginal_costs --{class: "change"}euro / MWh
max_consumption_price --{class: "change"}euro / MWh
capital_expenditures 1,425 K1,425 K{class: "change"}euro / unit / year
operating_expenses 1,574 K1,574 K{class: "change"}euro / unit / year
operating_expenses_including_fuel 1,574 K1,574 K{class: "change"}euro / unit / year
revenue 00{class: "change"}euro / unit / year
merit_order
merit_order_full_load_hours --{class: "change"}
merit_order_capacity_factor --{class: "change"}
merit_order_position --{class: "change"}
security_of_supply
availability 00{class: "change"}
part_load_operating_point --{class: "change"}
part_load_efficiency_penalty --{class: "change"}
forecasting_error --{class: "change"}
misc
demand_expected_value 5.81 B5.81 B{class: "change"}
excel_id --{class: "change"}
max_demand --{class: "change"}
Node Calculations Present Future Change Unit
demand
demand 5.81 B5.81 B{class: "change"}
preset_demand --{class: "change"}
demand_of_sustainable 00{class: "change"}
weighted_carrier_cost_per_mj 00{class: "change"}
weighted_carrier_co2_per_mj 00{class: "change"}
sustainability_share 0.960.966{class: "change"}
primary_demand 271.66 M454.45 M{class: "change"}
primary_demand_of_fossil 10.75 M15.24 M{class: "change"}
primary_demand_of_sustainable 260.91 M439.2 M{class: "change"}
primary_demand_of_electricity 248 K27.81 M{class: "change"}
primary_demand_of_coal 806 K97.52 M{class: "change"}
primary_demand_of_lng 3,552 K3,351 K{class: "change"}
primary_demand_of_wet_biomass 26.57 M29.4 M{class: "change"}
primary_demand_of_natural_gas 239.53 M225.72 M{class: "change"}
primary_demand_of_biogenic_waste 105 K21.14 M{class: "change"}
primary_demand_of_dry_biomass 471 K0{class: "change"}
primary_demand_of_non_biogenic_waste 93,085.618.75 M{class: "change"}
primary_demand_of_uranium_oxide 216 K24.71 M{class: "change"}
primary_demand_of_imported_electricity 67,4155,091 K{class: "change"}
technical
input_capacity 1414{class: "change"}
electric_based_input_capacity --{class: "change"}MWinput
heat_based_input_capacity 1414{class: "change"}MWinput
cooling_based_input_capacity --{class: "change"}MWinput
number_of_units 19.219.2{class: "change"}
costs_per_plant
total_costs_per(:plant) 3,055 K3,044 K{class: "change"}euro / plant
fixed_costs_per(:plant) 2,839 K2,839 K{class: "change"}
cost_of_capital_per(:plant) 535 K535 K{class: "change"}
depreciation_costs_per(:plant) 891 K891 K{class: "change"}
variable_costs_per(:plant) 216 K205 K{class: "change"}
fuel_costs_per(:plant) 00{class: "change"}
co2_emissions_costs_per(:plant) 00{class: "change"}
captured_biogenic_co2_costs_per(:plant) 00{class: "change"}
fixed_operation_and_maintenance_costs_per(:plant) 1,414 K1,414 K{class: "change"}
variable_operation_and_maintenance_costs_per(:plant) 160 K160 K{class: "change"}
total_initial_investment_per(:plant) 26.73 M26.73 M{class: "change"}
costs_per_node
total_costs_per(:node) 58.66 M58.44 M{class: "change"}
fixed_costs_per(:node) 54.51 M54.51 M{class: "change"}
cost_of_capital_per(:node) 10.26 M10.26 M{class: "change"}
depreciation_costs_per(:node) 17.1 M17.1 M{class: "change"}
variable_costs_per(:node) 4,147 K3,928 K{class: "change"}
fuel_costs_per(:node) 00{class: "change"}
co2_emissions_costs_per(:node) 00{class: "change"}
captured_biogenic_co2_costs_per(:node) 00{class: "change"}
fixed_operation_and_maintenance_costs_per(:node) 27.15 M27.15 M{class: "change"}
variable_operation_and_maintenance_costs_per(:node) 3,064 K3,064 K{class: "change"}
total_initial_investment_per(:node) 513.12 M513.12 M{class: "change"}
costs_per_mw_electricity
total_costs_per(:mw_electricity) 00{class: "change"}
fixed_costs_per(:mw_electricity) 00{class: "change"}
cost_of_capital_per(:mw_electricity) 00{class: "change"}
depreciation_costs_per(:mw_electricity) 00{class: "change"}
variable_costs_per(:mw_electricity) 00{class: "change"}
fuel_costs_per(:mw_electricity) NaNNaN{class: "change"}
co2_emissions_costs_per(:mw_electricity) NaNNaN{class: "change"}
captured_biogenic_co2_costs_per(:mw_electricity) NaNNaN{class: "change"}
fixed_operation_and_maintenance_costs_per(:mw_electricity) 00{class: "change"}
variable_operation_and_maintenance_costs_per(:mw_electricity) 00{class: "change"}
total_initial_investment_per(:mw_electricity) 00{class: "change"}
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 00{class: "change"}
fixed_costs_per(:mwh_electricity) 00{class: "change"}
cost_of_capital_per(:mwh_electricity) 00{class: "change"}
depreciation_costs_per(:mwh_electricity) 00{class: "change"}
variable_costs_per(:mwh_electricity) 00{class: "change"}
fuel_costs_per(:mwh_electricity) NaNNaN{class: "change"}
co2_emissions_costs_per(:mwh_electricity) NaNNaN{class: "change"}
captured_biogenic_co2_costs_per(:mwh_electricity) NaNNaN{class: "change"}
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 00{class: "change"}
variable_operation_and_maintenance_costs_per(:mwh_electricity) 00{class: "change"}
total_initial_investment_per(:mwh_electricity) 00{class: "change"}
costs_per_mw_heat
total_costs_per(:mw_heat) 218 K217 K{class: "change"}
fixed_costs_per(:mw_heat) 203 K203 K{class: "change"}
cost_of_capital_per(:mw_heat) 38,18038,180{class: "change"}
depreciation_costs_per(:mw_heat) 63,633.363,633.3{class: "change"}
variable_costs_per(:mw_heat) 15,427.914,614.9{class: "change"}
fuel_costs_per(:mw_heat) 00{class: "change"}
co2_emissions_costs_per(:mw_heat) 00{class: "change"}
captured_biogenic_co2_costs_per(:mw_heat) 00{class: "change"}
fixed_operation_and_maintenance_costs_per(:mw_heat) 101 K101 K{class: "change"}
variable_operation_and_maintenance_costs_per(:mw_heat) 11,40011,400{class: "change"}
total_initial_investment_per(:mw_heat) 1,909 K1,909 K{class: "change"}
costs_per_mwh_heat
total_costs_per(:mwh_heat) 36.3736.24{class: "change"}
fixed_costs_per(:mwh_heat) 33.833.8{class: "change"}
cost_of_capital_per(:mwh_heat) 6.366.36{class: "change"}
depreciation_costs_per(:mwh_heat) 10.6110.61{class: "change"}
variable_costs_per(:mwh_heat) 2.572.44{class: "change"}
fuel_costs_per(:mwh_heat) 00{class: "change"}
co2_emissions_costs_per(:mwh_heat) 00{class: "change"}
captured_biogenic_co2_costs_per(:mwh_heat) 00{class: "change"}
fixed_operation_and_maintenance_costs_per(:mwh_heat) 16.8316.83{class: "change"}
variable_operation_and_maintenance_costs_per(:mwh_heat) 1.91.9{class: "change"}
total_initial_investment_per(:mwh_heat) 318.2318.2{class: "change"}