Present 0 0 0
Future 0 0 0
Edges 0 Outputs
Node MJ Type
households_useful_demand_for_cooling 0 Share
100.0 %
0.0 %
Inputs Edges 0
94.76 %
Type MJ Node
Share 0 environment_water_ambient_cold
5.24 %
Type MJ Node
Share 0 households_final_demand_for_cooling_electricity
Edges 0 Outputs
Node MJ Type
households_useful_demand_for_cooling 0 Share
100.0 %
0.0 %
Inputs Edges 0
94.76 %
Type MJ Node
Share 0 environment_water_ambient_cold
5.24 %
Type MJ Node
Share 0 households_final_demand_for_cooling_electricity

Details

Sector households
Use energetic
Merit Order
group
households_cooling
level
lv
subtype
generic
type
consumer
Node groups
  1. heat_production
  2. application_group
  3. lv_net_demand
  4. wacc_households
  5. costs_building_and_installations_households
Used in Gqueries
  1. households_cooling_heatpump_surface_water_water_ts_electricity_input_of_electricity
  2. lv_households_cooling_load_curve
Used in Inputs
  1. households_cooling_heatpump_surface_water_water_ts_electricity_share
Method Label Present Future Unit
technical
coefficient_of_performance Coefficient of Performance 19.09 19.09 COP
heat_output_capacity Heat capacity per unit 2.25 2.25 MW / unit
full_load_hours Full load hours 2,190 2,190 hour / year
cost
total_investment_over_lifetime_per(:plant) Investment over lifetime per plant 954 K 954 K EUR / unit
fixed_operation_and_maintenance_costs_per(:plant) Fixed operation and maintenance costs 67,530 67,530 EUR / unit / year
variable_operation_and_maintenance_costs_per(:full_load_hour) Variable operation and maintenance costs 0 0 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
technical_lifetime Technical lifetime 30 30 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 00{class: "change"}MWe
heat_output_capacity 2.252.25{class: "change"}MWth
hydrogen_output_capacity 00{class: "change"}MW
free_co2_factor 00{class: "change"}
ccs_capture_rate --{class: "change"}
construction_time 00{class: "change"}
electrical_efficiency_when_using_coal --{class: "change"}
electrical_efficiency_when_using_wood_pellets --{class: "change"}
full_load_hours 2,1902,190{class: "change"}
households_supplied_per_unit --{class: "change"}
land_use_per_unit --{class: "change"}
takes_part_in_ets 00{class: "change"}yes=1 / no=0
technical_lifetime 3030{class: "change"}year
typical_input_capacity --{class: "change"}MWinput
output_capacity --{class: "change"}MW
input_efficiency --{class: "change"}
output_efficiency --{class: "change"}
cost
initial_investment 954 K954 K{class: "change"}euro / unit
ccs_investment 00{class: "change"}euro / unit
cost_of_installing 00{class: "change"}euro / unit
decommissioning_costs 00{class: "change"}euro / unit
fixed_operation_and_maintenance_costs_per_year 67,53067,530{class: "change"}euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 00{class: "change"}euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 00{class: "change"}euro / full load hour
fixed_costs_per_mw_input_capacity --{class: "change"}euro / MWinput
costs_per_mj --{class: "change"}
wacc 0.040.04{class: "change"}
profitability --{class: "change"}profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity --{class: "change"}eur/MWh
marginal_costs --{class: "change"}euro / MWh
max_consumption_price --{class: "change"}euro / MWh
capital_expenditures 50,853.350,853.3{class: "change"}euro / unit / year
operating_expenses 67,53067,530{class: "change"}euro / unit / year
operating_expenses_including_fuel 67,53067,530{class: "change"}euro / unit / year
revenue 00{class: "change"}euro / unit / year
merit_order
merit_order_full_load_hours --{class: "change"}
merit_order_capacity_factor --{class: "change"}
merit_order_position --{class: "change"}
security_of_supply
availability 00{class: "change"}
part_load_operating_point --{class: "change"}
part_load_efficiency_penalty --{class: "change"}
forecasting_error --{class: "change"}
misc
demand_expected_value 00{class: "change"}
excel_id --{class: "change"}
max_demand --{class: "change"}
Node Calculations Present Future Change Unit
demand
demand 00{class: "change"}
preset_demand --{class: "change"}
demand_of_sustainable 00{class: "change"}
weighted_carrier_cost_per_mj 00{class: "change"}
weighted_carrier_co2_per_mj 00{class: "change"}
sustainability_share 0.9630.96{class: "change"}
primary_demand 00{class: "change"}
primary_demand_of_fossil 00{class: "change"}
primary_demand_of_sustainable 00{class: "change"}
technical
input_capacity 2.252.25{class: "change"}
electric_based_input_capacity --{class: "change"}MWinput
heat_based_input_capacity --{class: "change"}MWinput
cooling_based_input_capacity 2.252.25{class: "change"}MWinput
number_of_units 00{class: "change"}
costs_per_plant
total_costs_per(:plant) 121 K121 K{class: "change"}euro / plant
fixed_costs_per(:plant) 118 K118 K{class: "change"}
cost_of_capital_per(:plant) 19,07019,070{class: "change"}
depreciation_costs_per(:plant) 31,783.331,783.3{class: "change"}
variable_costs_per(:plant) 2,583.52,500.8{class: "change"}
fuel_costs_per(:plant) 00{class: "change"}
co2_emissions_costs_per(:plant) 00{class: "change"}
captured_biogenic_co2_costs_per(:plant) 00{class: "change"}
fixed_operation_and_maintenance_costs_per(:plant) 67,53067,530{class: "change"}
variable_operation_and_maintenance_costs_per(:plant) 00{class: "change"}
total_initial_investment_per(:plant) 954 K954 K{class: "change"}
costs_per_node
total_costs_per(:node) 00{class: "change"}
fixed_costs_per(:node) 00{class: "change"}
cost_of_capital_per(:node) 00{class: "change"}
depreciation_costs_per(:node) 00{class: "change"}
variable_costs_per(:node) 00{class: "change"}
fuel_costs_per(:node) 00{class: "change"}
co2_emissions_costs_per(:node) 00{class: "change"}
captured_biogenic_co2_costs_per(:node) 00{class: "change"}
fixed_operation_and_maintenance_costs_per(:node) 00{class: "change"}
variable_operation_and_maintenance_costs_per(:node) 00{class: "change"}
total_initial_investment_per(:node) 00{class: "change"}
costs_per_mw_electricity
total_costs_per(:mw_electricity) 00{class: "change"}
fixed_costs_per(:mw_electricity) 00{class: "change"}
cost_of_capital_per(:mw_electricity) 00{class: "change"}
depreciation_costs_per(:mw_electricity) 00{class: "change"}
variable_costs_per(:mw_electricity) 00{class: "change"}
fuel_costs_per(:mw_electricity) NaNNaN{class: "change"}
co2_emissions_costs_per(:mw_electricity) NaNNaN{class: "change"}
captured_biogenic_co2_costs_per(:mw_electricity) NaNNaN{class: "change"}
fixed_operation_and_maintenance_costs_per(:mw_electricity) 00{class: "change"}
variable_operation_and_maintenance_costs_per(:mw_electricity) NaNNaN{class: "change"}
total_initial_investment_per(:mw_electricity) 00{class: "change"}
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 00{class: "change"}
fixed_costs_per(:mwh_electricity) 00{class: "change"}
cost_of_capital_per(:mwh_electricity) 00{class: "change"}
depreciation_costs_per(:mwh_electricity) 00{class: "change"}
variable_costs_per(:mwh_electricity) 00{class: "change"}
fuel_costs_per(:mwh_electricity) NaNNaN{class: "change"}
co2_emissions_costs_per(:mwh_electricity) NaNNaN{class: "change"}
captured_biogenic_co2_costs_per(:mwh_electricity) NaNNaN{class: "change"}
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 00{class: "change"}
variable_operation_and_maintenance_costs_per(:mwh_electricity) NaNNaN{class: "change"}
total_initial_investment_per(:mwh_electricity) 00{class: "change"}
costs_per_mw_heat
total_costs_per(:mw_heat) 53,76353,726.3{class: "change"}
fixed_costs_per(:mw_heat) 52,614.852,614.8{class: "change"}
cost_of_capital_per(:mw_heat) 8,475.68,475.6{class: "change"}
depreciation_costs_per(:mw_heat) 14,125.914,125.9{class: "change"}
variable_costs_per(:mw_heat) 1,148.21,111.5{class: "change"}
fuel_costs_per(:mw_heat) 00{class: "change"}
co2_emissions_costs_per(:mw_heat) 00{class: "change"}
captured_biogenic_co2_costs_per(:mw_heat) 00{class: "change"}
fixed_operation_and_maintenance_costs_per(:mw_heat) 30,013.330,013.3{class: "change"}
variable_operation_and_maintenance_costs_per(:mw_heat) 00{class: "change"}
total_initial_investment_per(:mw_heat) 424 K424 K{class: "change"}
costs_per_mwh_heat
total_costs_per(:mwh_heat) 24.5524.53{class: "change"}
fixed_costs_per(:mwh_heat) 24.0324.03{class: "change"}
cost_of_capital_per(:mwh_heat) 3.873.87{class: "change"}
depreciation_costs_per(:mwh_heat) 6.456.45{class: "change"}
variable_costs_per(:mwh_heat) 0.5240.508{class: "change"}
fuel_costs_per(:mwh_heat) 00{class: "change"}
co2_emissions_costs_per(:mwh_heat) 00{class: "change"}
captured_biogenic_co2_costs_per(:mwh_heat) 00{class: "change"}
fixed_operation_and_maintenance_costs_per(:mwh_heat) 13.713.7{class: "change"}
variable_operation_and_maintenance_costs_per(:mwh_heat) 00{class: "change"}
total_initial_investment_per(:mwh_heat) 193.5193.5{class: "change"}