Present 1.11 B 1.11 B 1.11 B
Future 1.11 B 1.11 B 1.11 B
Edges 1.11 B Outputs
21.13 %
Node MJ Type
other_useful_demand_useable_heat 877.43 M Share
78.87 %
Inputs Edges 1.11 B
100.0 %
Type MJ Node
Share 1.11 B other_final_demand_for_heat_crude_oil
Edges 1.11 B Outputs
21.13 %
Node MJ Type
other_useful_demand_useable_heat 877.43 M Share
78.87 %
Inputs Edges 1.11 B
100.0 %
Type MJ Node
Share 1.11 B other_final_demand_for_heat_crude_oil

Details

Sector other
Use energetic
Node groups
  1. heat_production
  2. application_group
  3. wacc_proven_tech
  4. costs_building_and_installations_industry
Used in Gqueries
  1. other_burner_crude_oil_delta_in_investment_cost_table
  2. other_burner_crude_oil_future_in_investment_cost_table
  3. other_burner_crude_oil_present_in_investment_cost_table
  4. total_cost_of_other_burner_crude_oil
Used in Inputs
Method Label Present Future Unit
technical
heat_output_conversion Heat efficiency (LHV) 78.9 78.9 %
heat_output_capacity Heat capacity per unit 5.0 5.0 MW / unit
full_load_hours Full load hours 2,190 2,190 hour / year
cost
total_investment_over_lifetime_per(:plant) Investment over lifetime per plant 300 K 300 K EUR / unit
fixed_operation_and_maintenance_costs_per(:plant) Fixed operation and maintenance costs 5,000 5,000 EUR / unit / year
variable_operation_and_maintenance_costs_per(:full_load_hour) Variable operation and maintenance costs 0 0 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
technical_lifetime Technical lifetime 15 15 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 00{class: "change"}MWe
heat_output_capacity 55{class: "change"}MWth
hydrogen_output_capacity 00{class: "change"}MW
free_co2_factor 00{class: "change"}
ccs_capture_rate --{class: "change"}
construction_time 00{class: "change"}
electrical_efficiency_when_using_coal --{class: "change"}
electrical_efficiency_when_using_wood_pellets --{class: "change"}
full_load_hours 2,1902,190{class: "change"}
households_supplied_per_unit --{class: "change"}
land_use_per_unit 00{class: "change"}
takes_part_in_ets 00{class: "change"}yes=1 / no=0
technical_lifetime 1515{class: "change"}year
typical_input_capacity --{class: "change"}MWinput
output_capacity --{class: "change"}MW
input_efficiency --{class: "change"}
output_efficiency --{class: "change"}
cost
initial_investment 300 K300 K{class: "change"}euro / unit
ccs_investment 00{class: "change"}euro / unit
cost_of_installing 00{class: "change"}euro / unit
decommissioning_costs 00{class: "change"}euro / unit
fixed_operation_and_maintenance_costs_per_year 5,0005,000{class: "change"}euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 00{class: "change"}euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 00{class: "change"}euro / full load hour
fixed_costs_per_mw_input_capacity --{class: "change"}euro / MWinput
costs_per_mj --{class: "change"}
wacc 0.040.04{class: "change"}
profitability --{class: "change"}profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity --{class: "change"}eur/MWh
marginal_costs --{class: "change"}euro / MWh
max_consumption_price --{class: "change"}euro / MWh
capital_expenditures 26,00026,000{class: "change"}euro / unit / year
operating_expenses 5,0005,000{class: "change"}euro / unit / year
operating_expenses_including_fuel 528 K528 K{class: "change"}euro / unit / year
revenue 00{class: "change"}euro / unit / year
merit_order
merit_order_full_load_hours --{class: "change"}
merit_order_capacity_factor --{class: "change"}
merit_order_position --{class: "change"}
security_of_supply
availability 00{class: "change"}
part_load_operating_point --{class: "change"}
part_load_efficiency_penalty --{class: "change"}
forecasting_error --{class: "change"}
misc
demand_expected_value 1.11 B1.11 B{class: "change"}
excel_id --{class: "change"}
max_demand --{class: "change"}
Node Calculations Present Future Change Unit
demand
demand 1.11 B1.11 B{class: "change"}
preset_demand --{class: "change"}
demand_of_sustainable 00{class: "change"}
weighted_carrier_cost_per_mj 0.010.01{class: "change"}
weighted_carrier_co2_per_mj 0.0730.073{class: "change"}
sustainability_share 00{class: "change"}
primary_demand 1.11 B1.11 B{class: "change"}
primary_demand_of_fossil 1.11 B1.11 B{class: "change"}
primary_demand_of_sustainable 00{class: "change"}
primary_demand_of_crude_oil 1.11 B1.11 B{class: "change"}
technical
input_capacity 6.346.34{class: "change"}
electric_based_input_capacity --{class: "change"}MWinput
heat_based_input_capacity 6.346.34{class: "change"}MWinput
cooling_based_input_capacity --{class: "change"}MWinput
number_of_units 22.2622.26{class: "change"}
costs_per_plant
total_costs_per(:plant) 554 K554 K{class: "change"}euro / plant
fixed_costs_per(:plant) 31,00031,000{class: "change"}
cost_of_capital_per(:plant) 6,0006,000{class: "change"}
depreciation_costs_per(:plant) 20,00020,000{class: "change"}
variable_costs_per(:plant) 523 K523 K{class: "change"}
fuel_costs_per(:plant) 523 K523 K{class: "change"}
co2_emissions_costs_per(:plant) 00{class: "change"}
captured_biogenic_co2_costs_per(:plant) 00{class: "change"}
fixed_operation_and_maintenance_costs_per(:plant) 5,0005,000{class: "change"}
variable_operation_and_maintenance_costs_per(:plant) 00{class: "change"}
total_initial_investment_per(:plant) 300 K300 K{class: "change"}
costs_per_node
total_costs_per(:node) 12.33 M12.33 M{class: "change"}
fixed_costs_per(:node) 690 K690 K{class: "change"}
cost_of_capital_per(:node) 134 K134 K{class: "change"}
depreciation_costs_per(:node) 445 K445 K{class: "change"}
variable_costs_per(:node) 11.64 M11.64 M{class: "change"}
fuel_costs_per(:node) 11.64 M11.64 M{class: "change"}
co2_emissions_costs_per(:node) 00{class: "change"}
captured_biogenic_co2_costs_per(:node) 00{class: "change"}
fixed_operation_and_maintenance_costs_per(:node) 111 K111 K{class: "change"}
variable_operation_and_maintenance_costs_per(:node) 00{class: "change"}
total_initial_investment_per(:node) 6,678 K6,678 K{class: "change"}
costs_per_mw_electricity
total_costs_per(:mw_electricity) 00{class: "change"}
fixed_costs_per(:mw_electricity) 00{class: "change"}
cost_of_capital_per(:mw_electricity) 00{class: "change"}
depreciation_costs_per(:mw_electricity) 00{class: "change"}
variable_costs_per(:mw_electricity) 00{class: "change"}
fuel_costs_per(:mw_electricity) 00{class: "change"}
co2_emissions_costs_per(:mw_electricity) NaNNaN{class: "change"}
captured_biogenic_co2_costs_per(:mw_electricity) NaNNaN{class: "change"}
fixed_operation_and_maintenance_costs_per(:mw_electricity) 00{class: "change"}
variable_operation_and_maintenance_costs_per(:mw_electricity) NaNNaN{class: "change"}
total_initial_investment_per(:mw_electricity) 00{class: "change"}
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 00{class: "change"}
fixed_costs_per(:mwh_electricity) 00{class: "change"}
cost_of_capital_per(:mwh_electricity) 00{class: "change"}
depreciation_costs_per(:mwh_electricity) 00{class: "change"}
variable_costs_per(:mwh_electricity) 00{class: "change"}
fuel_costs_per(:mwh_electricity) 00{class: "change"}
co2_emissions_costs_per(:mwh_electricity) NaNNaN{class: "change"}
captured_biogenic_co2_costs_per(:mwh_electricity) NaNNaN{class: "change"}
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 00{class: "change"}
variable_operation_and_maintenance_costs_per(:mwh_electricity) NaNNaN{class: "change"}
total_initial_investment_per(:mwh_electricity) 00{class: "change"}
costs_per_mw_heat
total_costs_per(:mw_heat) 111 K111 K{class: "change"}
fixed_costs_per(:mw_heat) 6,2006,200{class: "change"}
cost_of_capital_per(:mw_heat) 1,2001,200{class: "change"}
depreciation_costs_per(:mw_heat) 4,0004,000{class: "change"}
variable_costs_per(:mw_heat) 105 K105 K{class: "change"}
fuel_costs_per(:mw_heat) 105 K105 K{class: "change"}
co2_emissions_costs_per(:mw_heat) 00{class: "change"}
captured_biogenic_co2_costs_per(:mw_heat) 00{class: "change"}
fixed_operation_and_maintenance_costs_per(:mw_heat) 1,0001,000{class: "change"}
variable_operation_and_maintenance_costs_per(:mw_heat) 00{class: "change"}
total_initial_investment_per(:mw_heat) 60,00060,000{class: "change"}
costs_per_mwh_heat
total_costs_per(:mwh_heat) 50.5950.59{class: "change"}
fixed_costs_per(:mwh_heat) 2.832.83{class: "change"}
cost_of_capital_per(:mwh_heat) 0.5480.548{class: "change"}
depreciation_costs_per(:mwh_heat) 1.831.83{class: "change"}
variable_costs_per(:mwh_heat) 47.7647.76{class: "change"}
fuel_costs_per(:mwh_heat) 47.7647.76{class: "change"}
co2_emissions_costs_per(:mwh_heat) 00{class: "change"}
captured_biogenic_co2_costs_per(:mwh_heat) 00{class: "change"}
fixed_operation_and_maintenance_costs_per(:mwh_heat) 0.4570.457{class: "change"}
variable_operation_and_maintenance_costs_per(:mwh_heat) 00{class: "change"}
total_initial_investment_per(:mwh_heat) 27.427.4{class: "change"}