Present 0 0 0
Future 0 0 0
Edges 0 Outputs
Node MJ Type
agriculture_locally_available_electricity 0 Flexible
Reversed
42.0 %
4.5 %
Node MJ Type
agriculture_locally_available_steam_hot_water 0 Flexible
Reversed
53.5 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_national_gas_network_natural_gas
Edges 0 Outputs
Node MJ Type
agriculture_locally_available_electricity 0 Flexible
Reversed
42.0 %
4.5 %
Node MJ Type
agriculture_locally_available_steam_hot_water 0 Flexible
Reversed
53.5 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_national_gas_network_natural_gas

Details

Sector agriculture
Use energetic
Merit Order
group
weather/agriculture_heating
level
mv
subtype
must_run
type
producer
Network Gas
profile
weather/agriculture_heating
type
consumer
Node groups
  1. preset_demand
  2. electricity_production
  3. heat_production
  4. must_run_electricity_production
  5. wacc_proven_tech
  6. costs_production_chp_plants
  7. sankey_conversion_group
Used in Gqueries
  1. agriculture_chp_engine_must_run_network_gas
  2. agriculture_chp_engine_must_run_network_gas_capacity_in_chp_properties
  3. agriculture_chp_engine_must_run_network_gas_electricity_production_in_chp_properties
  4. agriculture_chp_engine_must_run_network_gas_heat_production_in_chp_properties
  5. agriculture_chp_engine_must_run_network_gas_number_of_units_in_chp_properties
  6. agriculture_supply_chp_engine_must_run_network_gas
  7. factsheet_supply_heat_from_rest_and_geothermal
  8. merit_order_agriculture_chp_gas_must_run_availability_in_merit_order_table
  9. merit_order_agriculture_chp_gas_must_run_capacity_in_merit_order_table
  10. merit_order_agriculture_chp_gas_must_run_full_load_hours_in_merit_order_table
  11. merit_order_agriculture_chp_gas_must_run_load_factor_in_merit_order_table
  12. merit_order_agriculture_chp_gas_must_run_operating_costs_in_merit_order_table
  13. merit_order_agriculture_chp_gas_must_run_position_in_merit_order_table
Used in Inputs
  1. capacity_of_agriculture_chp_engine_network_gas_must_run
  2. efficiency_agriculture_chp_engine_must_run_network_gas_electricity
  3. efficiency_agriculture_chp_engine_must_run_network_gas_heat
  4. investment_costs_combustion_gas_plant
  5. om_costs_combustion_gas_plant
Method Label Present Future Unit
technical
electricity_output_capacity * number_of_units Installed electrical capacity 0 0 MW
electricity_output_conversion Electrical efficiency 42.0 42.0 %
heat_output_conversion Heat efficiency 53.5 53.5 %
full_load_hours Full load hours 3,920 3,920 hour / year
cost
total_investment_over_lifetime_per(:mw_electricity) Investment over lifetime per MW 607902 607902 EUR / MW
fixed_operation_and_maintenance_costs_per(:mw_electricity) Fixed operation and maintenance costs 0 0 EUR / MW / year
variable_operation_and_maintenance_costs_per_full_load_hour Variable operation and maintenance costs 16 16 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
technical_lifetime Technical lifetime 20 20 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 1.971.97{:class=>"change"}MWe
heat_output_capacity 2.512.51{:class=>"change"}MWth
hydrogen_output_capacity 00{:class=>"change"}MW
free_co2_factor 00{:class=>"change"}
ccs_capture_rate --{:class=>"change"}
construction_time 11{:class=>"change"}
electrical_efficiency_when_using_coal --{:class=>"change"}
electrical_efficiency_when_using_wood_pellets --{:class=>"change"}
full_load_hours 3,9203,920{:class=>"change"}
households_supplied_per_unit --{:class=>"change"}
land_use_per_unit --{:class=>"change"}
takes_part_in_ets 00{:class=>"change"}yes=1 / no=0
technical_lifetime 2020{:class=>"change"}year
typical_input_capacity 4.74.7{:class=>"change"}MWinput
output_capacity --{:class=>"change"}MW
input_efficiency --{:class=>"change"}
output_efficiency --{:class=>"change"}
cost
initial_investment 1,200 K1,200 K{:class=>"change"}euro / unit
ccs_investment 00{:class=>"change"}euro / unit
cost_of_installing 00{:class=>"change"}euro / unit
decommissioning_costs 00{:class=>"change"}euro / unit
fixed_operation_and_maintenance_costs_per_year 00{:class=>"change"}euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 1616{:class=>"change"}euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 00{:class=>"change"}euro / full load hour
fixed_costs_per_mw_input_capacity --{:class=>"change"}euro / MWinput
costs_per_mj --{:class=>"change"}
wacc 0.040.04{:class=>"change"}
profitability --{:class=>"change"}profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity --{:class=>"change"}eur/MWh
marginal_costs 41.9841.98{:class=>"change"}euro / MWh
max_consumption_price 41.9841.98{:class=>"change"}euro / MWh
merit_order
merit_order_full_load_hours --{:class=>"change"}
merit_order_capacity_factor --{:class=>"change"}
merit_order_position --{:class=>"change"}
security_of_supply
availability 0.950.95{:class=>"change"}
part_load_operating_point --{:class=>"change"}
part_load_efficiency_penalty --{:class=>"change"}
forecasting_error --{:class=>"change"}
misc
demand_expected_value --{:class=>"change"}
excel_id --{:class=>"change"}
max_demand --{:class=>"change"}
Node Calculations Present Future Change Unit
demand
demand 00{:class=>"change"}
preset_demand 00{:class=>"change"}
demand_of_sustainable 00{:class=>"change"}
weighted_carrier_cost_per_mj 0.0040.004{:class=>"change"}
weighted_carrier_co2_per_mj 0.0560.056{:class=>"change"}
sustainability_share 0.0050.005{:class=>"change"}
final_demand 00{:class=>"change"}
primary_demand 00{:class=>"change"}
primary_demand_of_fossil 00{:class=>"change"}
primary_demand_of_sustainable 00{:class=>"change"}
technical
input_capacity 4.74.7{:class=>"change"}
electric_based_input_capacity 4.74.7{:class=>"change"}MWinput
heat_based_input_capacity 4.74.7{:class=>"change"}MWinput
cooling_based_input_capacity --{:class=>"change"}MWinput
number_of_units 00{:class=>"change"}
costs_per_plant
total_costs_per(:plant) 410 K410 K{:class=>"change"}euro / plant
fixed_costs_per(:plant) 85,20085,200{:class=>"change"}
cost_of_capital_per(:plant) 25,20025,200{:class=>"change"}
depreciation_costs_per(:plant) 60,00060,000{:class=>"change"}
variable_costs_per(:plant) 325 K325 K{:class=>"change"}
fuel_costs_per(:plant) 262 K262 K{:class=>"change"}
co2_emissions_costs_per(:plant) 00{:class=>"change"}
captured_biogenic_co2_costs_per(:plant) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:plant) 00{:class=>"change"}
variable_operation_and_maintenance_costs_per(:plant) 62,72062,720{:class=>"change"}
total_initial_investment_per(:plant) 1,200 K1,200 K{:class=>"change"}
costs_per_node
total_costs_per(:node) 00{:class=>"change"}
fixed_costs_per(:node) 00{:class=>"change"}
cost_of_capital_per(:node) 00{:class=>"change"}
depreciation_costs_per(:node) 00{:class=>"change"}
variable_costs_per(:node) 00{:class=>"change"}
fuel_costs_per(:node) 00{:class=>"change"}
co2_emissions_costs_per(:node) 00{:class=>"change"}
captured_biogenic_co2_costs_per(:node) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:node) 00{:class=>"change"}
variable_operation_and_maintenance_costs_per(:node) 00{:class=>"change"}
total_initial_investment_per(:node) 00{:class=>"change"}
costs_per_mw_electricity
total_costs_per(:mw_electricity) 208 K208 K{:class=>"change"}
fixed_costs_per(:mw_electricity) 43,161.143,161.1{:class=>"change"}
cost_of_capital_per(:mw_electricity) 12,76612,766{:class=>"change"}
depreciation_costs_per(:mw_electricity) 30,395.130,395.1{:class=>"change"}
variable_costs_per(:mw_electricity) 165 K165 K{:class=>"change"}
fuel_costs_per(:mw_electricity) 133 K133 K{:class=>"change"}
co2_emissions_costs_per(:mw_electricity) 00{:class=>"change"}
captured_biogenic_co2_costs_per(:mw_electricity) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:mw_electricity) 00{:class=>"change"}
variable_operation_and_maintenance_costs_per(:mw_electricity) 31,77331,773{:class=>"change"}
total_initial_investment_per(:mw_electricity) 608 K608 K{:class=>"change"}
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 52.9952.99{:class=>"change"}
fixed_costs_per(:mwh_electricity) 11.0111.01{:class=>"change"}
cost_of_capital_per(:mwh_electricity) 3.263.26{:class=>"change"}
depreciation_costs_per(:mwh_electricity) 7.757.75{:class=>"change"}
variable_costs_per(:mwh_electricity) 41.9841.98{:class=>"change"}
fuel_costs_per(:mwh_electricity) 33.8733.87{:class=>"change"}
co2_emissions_costs_per(:mwh_electricity) 00{:class=>"change"}
captured_biogenic_co2_costs_per(:mwh_electricity) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 00{:class=>"change"}
variable_operation_and_maintenance_costs_per(:mwh_electricity) 8.118.11{:class=>"change"}
total_initial_investment_per(:mwh_electricity) 155.1155.1{:class=>"change"}
costs_per_mw_heat
total_costs_per(:mw_heat) 163 K163 K{:class=>"change"}
fixed_costs_per(:mw_heat) 33,883.533,883.5{:class=>"change"}
cost_of_capital_per(:mw_heat) 10,021.910,021.9{:class=>"change"}
depreciation_costs_per(:mw_heat) 23,861.623,861.6{:class=>"change"}
variable_costs_per(:mw_heat) 129 K129 K{:class=>"change"}
fuel_costs_per(:mw_heat) 104 K104 K{:class=>"change"}
co2_emissions_costs_per(:mw_heat) 00{:class=>"change"}
captured_biogenic_co2_costs_per(:mw_heat) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:mw_heat) 00{:class=>"change"}
variable_operation_and_maintenance_costs_per(:mw_heat) 24,943.324,943.3{:class=>"change"}
total_initial_investment_per(:mw_heat) 477 K477 K{:class=>"change"}
costs_per_mwh_heat
total_costs_per(:mwh_heat) 41.641.6{:class=>"change"}
fixed_costs_per(:mwh_heat) 8.648.64{:class=>"change"}
cost_of_capital_per(:mwh_heat) 2.562.56{:class=>"change"}
depreciation_costs_per(:mwh_heat) 6.096.09{:class=>"change"}
variable_costs_per(:mwh_heat) 32.9632.96{:class=>"change"}
fuel_costs_per(:mwh_heat) 26.5926.59{:class=>"change"}
co2_emissions_costs_per(:mwh_heat) 00{:class=>"change"}
captured_biogenic_co2_costs_per(:mwh_heat) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:mwh_heat) 00{:class=>"change"}
variable_operation_and_maintenance_costs_per(:mwh_heat) 6.366.36{:class=>"change"}
total_initial_investment_per(:mwh_heat) 121.7121.7{:class=>"change"}