Present 0 0 0
Future 0 0 0
Edges 0 Outputs
Node MJ Type
energy_battery_curtailed_solar_electricity 0 Share
Reversed
energy_battery_solar_electricity 0 Share
Reversed
energy_flexibility_solar_batteries_electricity 0 Share
Reversed
17.0 %
83.0 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 environment_sun_solar_radiation
Edges 0 Outputs
Node MJ Type
energy_battery_curtailed_solar_electricity 0 Share
Reversed
energy_battery_solar_electricity 0 Share
Reversed
energy_flexibility_solar_batteries_electricity 0 Share
Reversed
17.0 %
83.0 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 environment_sun_solar_radiation

Details

Sector energy
Use energetic
Merit Order
group
dynamic: solar_pv
level
hv
relations
curtailment: energy_battery_curtailed_solar_electricity output: energy_battery_solar_electricity storage: energy_flexibility_solar_batteries_electricity
subtype
always_on_battery_park
type
producer
Node groups
  1. preset_demand
  2. primary_energy_demand
  3. sustainable_production
  4. volatile_production
  5. wacc_proven_tech
  6. costs_production_power_plants
  7. merit_order_csv_exclude
Used in Gqueries
  1. energy_battery_solar_direct_to_grid_electricity_output
  2. energy_battery_solar_pv_curtailed_electricity_percentage
  3. energy_battery_solar_pv_installed_capacity
  4. energy_battery_solar_pv_peak_power_before_curtailment
  5. energy_battery_solar_pv_production_before_curtailment
  6. factsheet_installed_capacity_of_solar_pv
  7. factsheet_solar_pv_plants_land_use
  8. factsheet_supply_from_solar_pv_plants
  9. land_use_solar_wind_battery_solar_pv_capacity_per_unit
  10. land_use_solar_wind_battery_solar_pv_electricity_output
  11. land_use_solar_wind_battery_solar_pv_full_load_hours
  12. land_use_solar_wind_battery_solar_pv_installed_capacity
  13. land_use_solar_wind_battery_solar_pv_land_use_per_unit
  14. land_use_solar_wind_battery_solar_pv_number_of_units
  15. merit_order_battery_solar_pv_availability_in_merit_order_table
  16. merit_order_battery_solar_pv_capacity_in_merit_order_table
  17. merit_order_battery_solar_pv_full_load_hours_in_merit_order_table
  18. merit_order_battery_solar_pv_load_factor_in_merit_order_table
  19. merit_order_battery_solar_pv_operating_costs_in_merit_order_table
Used in Inputs
  1. capacity_of_energy_battery_solar_pv_solar_radiation
  2. efficiency_energy_power_solar_pv_solar_radiation
  3. flh_of_solar_pv_solar_radiation
  4. flh_of_solar_pv_solar_radiation_user_curve
  5. investment_costs_solar_solar_panels
  6. settings_weather_curve_set
Method Label Present Future Unit
technical
electricity_output_capacity * number_of_units Installed electrical capacity 0 0 MW
electricity_output_conversion Electrical efficiency 17.0 17.0 %
full_load_hours Full load hours 867 867 hour / year
cost
total_investment_over_lifetime_per(:mw_electricity) Investment over lifetime per MW 871000 871000 EUR / MW
fixed_operation_and_maintenance_costs_per(:mw_electricity) Fixed operation and maintenance costs 15900 15900 EUR / MW / year
variable_operation_and_maintenance_costs_per_full_load_hour Variable operation and maintenance costs 0 0 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
land_use_per_unit / electricity_output_capacity Land use 0.01 0.01 km2 / MW
technical_lifetime Technical lifetime 25 25 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 2020{:class=>"change"}MWe
heat_output_capacity 00{:class=>"change"}MWth
hydrogen_output_capacity 00{:class=>"change"}MW
free_co2_factor 00{:class=>"change"}
ccs_capture_rate --{:class=>"change"}
construction_time 0.50.5{:class=>"change"}
electrical_efficiency_when_using_coal --{:class=>"change"}
electrical_efficiency_when_using_wood_pellets --{:class=>"change"}
full_load_hours 867867{:class=>"change"}
households_supplied_per_unit --{:class=>"change"}
land_use_per_unit 0.20.2{:class=>"change"}
takes_part_in_ets 00{:class=>"change"}yes=1 / no=0
technical_lifetime 2525{:class=>"change"}year
typical_input_capacity --{:class=>"change"}MWinput
output_capacity --{:class=>"change"}MW
input_efficiency --{:class=>"change"}
output_efficiency --{:class=>"change"}
cost
initial_investment 17.42 M17.42 M{:class=>"change"}euro / unit
ccs_investment 00{:class=>"change"}euro / unit
cost_of_installing 00{:class=>"change"}euro / unit
decommissioning_costs 00{:class=>"change"}euro / unit
fixed_operation_and_maintenance_costs_per_year 318 K318 K{:class=>"change"}euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 00{:class=>"change"}euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 00{:class=>"change"}euro / full load hour
fixed_costs_per_mw_input_capacity --{:class=>"change"}euro / MWinput
costs_per_mj --{:class=>"change"}
wacc 0.040.04{:class=>"change"}
profitability --{:class=>"change"}profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity --{:class=>"change"}eur/MWh
marginal_costs 00{:class=>"change"}euro / MWh
max_consumption_price 00{:class=>"change"}euro / MWh
merit_order
merit_order_full_load_hours --{:class=>"change"}
merit_order_capacity_factor --{:class=>"change"}
merit_order_position --{:class=>"change"}
security_of_supply
availability 0.980.98{:class=>"change"}
part_load_operating_point 0.70.7{:class=>"change"}
part_load_efficiency_penalty 0.10.1{:class=>"change"}
forecasting_error 0.050.05{:class=>"change"}
misc
demand_expected_value --{:class=>"change"}
excel_id --{:class=>"change"}
max_demand --{:class=>"change"}
Node Calculations Present Future Change Unit
demand
demand 00{:class=>"change"}
preset_demand 00{:class=>"change"}
demand_of_sustainable 00{:class=>"change"}
weighted_carrier_cost_per_mj 00{:class=>"change"}
weighted_carrier_co2_per_mj 00{:class=>"change"}
sustainability_share 11{:class=>"change"}
final_demand 00{:class=>"change"}
primary_demand 00{:class=>"change"}
primary_demand_of_fossil 00{:class=>"change"}
primary_demand_of_sustainable 00{:class=>"change"}
technical
input_capacity 117.6117.6{:class=>"change"}
electric_based_input_capacity 117.6117.6{:class=>"change"}MWinput
heat_based_input_capacity --{:class=>"change"}MWinput
cooling_based_input_capacity --{:class=>"change"}MWinput
number_of_units 00{:class=>"change"}
costs_per_plant
total_costs_per(:plant) 1,370 K1,370 K{:class=>"change"}euro / plant
fixed_costs_per(:plant) 1,370 K1,370 K{:class=>"change"}
cost_of_capital_per(:plant) 355 K355 K{:class=>"change"}
depreciation_costs_per(:plant) 697 K697 K{:class=>"change"}
variable_costs_per(:plant) 00{:class=>"change"}
fuel_costs_per(:plant) 00{:class=>"change"}
co2_emissions_costs_per(:plant) 00{:class=>"change"}
captured_biogenic_co2_costs_per(:plant) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:plant) 318 K318 K{:class=>"change"}
variable_operation_and_maintenance_costs_per(:plant) 00{:class=>"change"}
total_initial_investment_per(:plant) 17.42 M17.42 M{:class=>"change"}
costs_per_node
total_costs_per(:node) 00{:class=>"change"}
fixed_costs_per(:node) 00{:class=>"change"}
cost_of_capital_per(:node) 00{:class=>"change"}
depreciation_costs_per(:node) 00{:class=>"change"}
variable_costs_per(:node) 00{:class=>"change"}
fuel_costs_per(:node) 00{:class=>"change"}
co2_emissions_costs_per(:node) 00{:class=>"change"}
captured_biogenic_co2_costs_per(:node) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:node) 00{:class=>"change"}
variable_operation_and_maintenance_costs_per(:node) 00{:class=>"change"}
total_initial_investment_per(:node) 00{:class=>"change"}
costs_per_mw_electricity
total_costs_per(:mw_electricity) 68,508.468,508.4{:class=>"change"}
fixed_costs_per(:mw_electricity) 68,508.468,508.4{:class=>"change"}
cost_of_capital_per(:mw_electricity) 17,768.417,768.4{:class=>"change"}
depreciation_costs_per(:mw_electricity) 34,84034,840{:class=>"change"}
variable_costs_per(:mw_electricity) 00{:class=>"change"}
fuel_costs_per(:mw_electricity) 00{:class=>"change"}
co2_emissions_costs_per(:mw_electricity) 00{:class=>"change"}
captured_biogenic_co2_costs_per(:mw_electricity) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:mw_electricity) 15,90015,900{:class=>"change"}
variable_operation_and_maintenance_costs_per(:mw_electricity) 00{:class=>"change"}
total_initial_investment_per(:mw_electricity) 871 K871 K{:class=>"change"}
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 79.0279.02{:class=>"change"}
fixed_costs_per(:mwh_electricity) 79.0279.02{:class=>"change"}
cost_of_capital_per(:mwh_electricity) 20.4920.49{:class=>"change"}
depreciation_costs_per(:mwh_electricity) 40.1840.18{:class=>"change"}
variable_costs_per(:mwh_electricity) 00{:class=>"change"}
fuel_costs_per(:mwh_electricity) 00{:class=>"change"}
co2_emissions_costs_per(:mwh_electricity) 00{:class=>"change"}
captured_biogenic_co2_costs_per(:mwh_electricity) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 18.3418.34{:class=>"change"}
variable_operation_and_maintenance_costs_per(:mwh_electricity) 00{:class=>"change"}
total_initial_investment_per(:mwh_electricity) 1,004.61,004.6{:class=>"change"}
costs_per_mw_heat
total_costs_per(:mw_heat) 00{:class=>"change"}
fixed_costs_per(:mw_heat) 00{:class=>"change"}
cost_of_capital_per(:mw_heat) 00{:class=>"change"}
depreciation_costs_per(:mw_heat) 00{:class=>"change"}
variable_costs_per(:mw_heat) NaNNaN{:class=>"change"}
fuel_costs_per(:mw_heat) NaNNaN{:class=>"change"}
co2_emissions_costs_per(:mw_heat) NaNNaN{:class=>"change"}
captured_biogenic_co2_costs_per(:mw_heat) NaNNaN{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:mw_heat) 00{:class=>"change"}
variable_operation_and_maintenance_costs_per(:mw_heat) NaNNaN{:class=>"change"}
total_initial_investment_per(:mw_heat) 00{:class=>"change"}
costs_per_mwh_heat
total_costs_per(:mwh_heat) 00{:class=>"change"}
fixed_costs_per(:mwh_heat) 00{:class=>"change"}
cost_of_capital_per(:mwh_heat) 00{:class=>"change"}
depreciation_costs_per(:mwh_heat) 00{:class=>"change"}
variable_costs_per(:mwh_heat) NaNNaN{:class=>"change"}
fuel_costs_per(:mwh_heat) NaNNaN{:class=>"change"}
co2_emissions_costs_per(:mwh_heat) NaNNaN{:class=>"change"}
captured_biogenic_co2_costs_per(:mwh_heat) NaNNaN{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:mwh_heat) 00{:class=>"change"}
variable_operation_and_maintenance_costs_per(:mwh_heat) NaNNaN{:class=>"change"}
total_initial_investment_per(:mwh_heat) 00{:class=>"change"}