Present 0 0 0
Future 0 0 0
Edges 0 Outputs
Node MJ Type
energy_power_hv_network_electricity 0 Flexible
Reversed
35.0 %
50.0 %
Node MJ Type
energy_transmission_ht_steam_hot_water 0 Flexible
Reversed
15.0 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_distribution_lignite
Edges 0 Outputs
Node MJ Type
energy_power_hv_network_electricity 0 Flexible
Reversed
35.0 %
50.0 %
Node MJ Type
energy_transmission_ht_steam_hot_water 0 Flexible
Reversed
15.0 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_distribution_lignite

Details

Sector energy
Use undefined
Heat network (HT)
group
self: electricity_output_curve
subtype
must_run
type
producer
Merit Order
level
hv
subtype
dispatchable
type
producer
Node groups
  1. preset_demand
  2. central_production
  3. electricity_production
  4. dispatchable_production
  5. heat_production
  6. hv_net_supply
  7. wacc_proven_tech
  8. primary_heat_infrastructure
  9. costs_production_chp_plants
  10. sankey_conversion_group
Used in Gqueries
  1. energy_chp_ultra_supercritical_ht_lignite_capacity_in_chp_properties
  2. energy_chp_ultra_supercritical_ht_lignite_electricity_production_in_chp_properties
  3. energy_chp_ultra_supercritical_ht_lignite_heat_production_in_chp_properties
  4. energy_chp_ultra_supercritical_ht_lignite_number_of_units_in_chp_properties
  5. energy_chp_ultra_supercritical_ht_lignite_output_of_steam_hot_water
  6. energy_chp_ultra_supercritical_lignite
  7. energy_chp_ultra_supercritical_lignite_ht_steam_hot_water_output_curve
  8. factsheet_supply_heat_from_rest_and_geothermal
  9. merit_order_lignite_chp_ht_availability_in_merit_order_table
  10. merit_order_lignite_chp_ht_capacity_in_merit_order_table
  11. merit_order_lignite_chp_ht_full_load_hours_in_merit_order_table
  12. merit_order_lignite_chp_ht_load_factor_in_merit_order_table
  13. merit_order_lignite_chp_ht_operating_costs_in_merit_order_table
  14. merit_order_lignite_chp_ht_position_in_merit_order_table
Used in Inputs
  1. capacity_of_energy_chp_ultra_supercritical_lignite
  2. investment_costs_combustion_coal_plant
  3. om_costs_combustion_coal_plant
  4. share_of_energy_chp_ultra_supercritical_ht_lignite
  5. share_of_energy_chp_ultra_supercritical_mt_lignite
Method Label Present Future Unit
technical
electricity_output_capacity * number_of_units Installed electrical capacity 0 0 MW
electricity_output_conversion Electrical efficiency 35.0 35.0 %
heat_output_conversion Heat efficiency 15.0 15.0 %
full_load_hours Full load hours 4,500 0 hour / year
cost
total_investment_over_lifetime_per(:mw_electricity) Investment over lifetime per MW 1750000 1750000 EUR / MW
fixed_operation_and_maintenance_costs_per(:mw_electricity) Fixed operation and maintenance costs 46400 46400 EUR / MW / year
variable_operation_and_maintenance_costs_per_full_load_hour Variable operation and maintenance costs 1540 1540 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? true true boolean
other
technical_lifetime Technical lifetime 35 35 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 700700{:class=>"change"}MWe
heat_output_capacity 300300{:class=>"change"}MWth
hydrogen_output_capacity 00{:class=>"change"}MW
free_co2_factor 00{:class=>"change"}
ccs_capture_rate --{:class=>"change"}
construction_time 44{:class=>"change"}
electrical_efficiency_when_using_coal --{:class=>"change"}
electrical_efficiency_when_using_wood_pellets --{:class=>"change"}
full_load_hours 4,5000{:class=>"change"}
households_supplied_per_unit --{:class=>"change"}
land_use_per_unit --{:class=>"change"}
takes_part_in_ets 11{:class=>"change"}yes=1 / no=0
technical_lifetime 3535{:class=>"change"}year
typical_input_capacity 2,0002,000{:class=>"change"}MWinput
output_capacity --{:class=>"change"}MW
input_efficiency --{:class=>"change"}
output_efficiency --{:class=>"change"}
cost
initial_investment 1.23 B1.23 B{:class=>"change"}euro / unit
ccs_investment 00{:class=>"change"}euro / unit
cost_of_installing 00{:class=>"change"}euro / unit
decommissioning_costs 00{:class=>"change"}euro / unit
fixed_operation_and_maintenance_costs_per_year 32.48 M32.48 M{:class=>"change"}euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 1,5401,540{:class=>"change"}euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 00{:class=>"change"}euro / full load hour
fixed_costs_per_mw_input_capacity --{:class=>"change"}euro / MWinput
costs_per_mj --{:class=>"change"}
wacc 0.040.04{:class=>"change"}
profitability -unprofitable{:class=>"change"}profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity --{:class=>"change"}eur/MWh
marginal_costs 20.9820.98{:class=>"change"}euro / MWh
max_consumption_price 20.9820.98{:class=>"change"}euro / MWh
merit_order
merit_order_full_load_hours --{:class=>"change"}
merit_order_capacity_factor --{:class=>"change"}
merit_order_position --{:class=>"change"}
security_of_supply
availability 0.90.9{:class=>"change"}
part_load_operating_point --{:class=>"change"}
part_load_efficiency_penalty --{:class=>"change"}
forecasting_error --{:class=>"change"}
misc
demand_expected_value --{:class=>"change"}
excel_id --{:class=>"change"}
max_demand --{:class=>"change"}
Node Calculations Present Future Change Unit
demand
demand 00{:class=>"change"}
preset_demand 00{:class=>"change"}
demand_of_sustainable 00{:class=>"change"}
weighted_carrier_cost_per_mj 0.0010.001{:class=>"change"}
weighted_carrier_co2_per_mj 0.1010.101{:class=>"change"}
sustainability_share 00{:class=>"change"}
final_demand 00{:class=>"change"}
primary_demand 00{:class=>"change"}
primary_demand_of_fossil 00{:class=>"change"}
primary_demand_of_sustainable 00{:class=>"change"}
technical
input_capacity 2,0002,000{:class=>"change"}
electric_based_input_capacity 2,0002,000{:class=>"change"}MWinput
heat_based_input_capacity 2,0002,000{:class=>"change"}MWinput
cooling_based_input_capacity --{:class=>"change"}MWinput
number_of_units 00{:class=>"change"}
costs_per_plant
total_costs_per(:plant) 186.2 M94.78 M{:class=>"change"}euro / plant
fixed_costs_per(:plant) 94.78 M94.78 M{:class=>"change"}
cost_of_capital_per(:plant) 27.3 M27.3 M{:class=>"change"}
depreciation_costs_per(:plant) 35 M35 M{:class=>"change"}
variable_costs_per(:plant) 91.42 M0{:class=>"change"}
fuel_costs_per(:plant) 35.64 M0{:class=>"change"}
co2_emissions_costs_per(:plant) 48.85 M0{:class=>"change"}
captured_biogenic_co2_costs_per(:plant) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:plant) 32.48 M32.48 M{:class=>"change"}
variable_operation_and_maintenance_costs_per(:plant) 6,930 K0{:class=>"change"}
total_initial_investment_per(:plant) 1.23 B1.23 B{:class=>"change"}
costs_per_node
total_costs_per(:node) 00{:class=>"change"}
fixed_costs_per(:node) 00{:class=>"change"}
cost_of_capital_per(:node) 00{:class=>"change"}
depreciation_costs_per(:node) 00{:class=>"change"}
variable_costs_per(:node) 00{:class=>"change"}
fuel_costs_per(:node) 00{:class=>"change"}
co2_emissions_costs_per(:node) 00{:class=>"change"}
captured_biogenic_co2_costs_per(:node) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:node) 00{:class=>"change"}
variable_operation_and_maintenance_costs_per(:node) 00{:class=>"change"}
total_initial_investment_per(:node) 00{:class=>"change"}
costs_per_mw_electricity
total_costs_per(:mw_electricity) 266 K135 K{:class=>"change"}
fixed_costs_per(:mw_electricity) 135 K135 K{:class=>"change"}
cost_of_capital_per(:mw_electricity) 39,00039,000{:class=>"change"}
depreciation_costs_per(:mw_electricity) 50,00050,000{:class=>"change"}
variable_costs_per(:mw_electricity) 131 K0{:class=>"change"}
fuel_costs_per(:mw_electricity) 50,914.30{:class=>"change"}
co2_emissions_costs_per(:mw_electricity) 69,783.90{:class=>"change"}
captured_biogenic_co2_costs_per(:mw_electricity) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:mw_electricity) 46,40046,400{:class=>"change"}
variable_operation_and_maintenance_costs_per(:mw_electricity) 9,9000{:class=>"change"}
total_initial_investment_per(:mw_electricity) 1,750 K1,750 K{:class=>"change"}
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 59.110{:class=>"change"}
fixed_costs_per(:mwh_electricity) 30.090{:class=>"change"}
cost_of_capital_per(:mwh_electricity) 8.670{:class=>"change"}
depreciation_costs_per(:mwh_electricity) 11.110{:class=>"change"}
variable_costs_per(:mwh_electricity) 29.02NaN{:class=>"change"}
fuel_costs_per(:mwh_electricity) 11.31NaN{:class=>"change"}
co2_emissions_costs_per(:mwh_electricity) 15.51NaN{:class=>"change"}
captured_biogenic_co2_costs_per(:mwh_electricity) 0NaN{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 10.310{:class=>"change"}
variable_operation_and_maintenance_costs_per(:mwh_electricity) 2.2NaN{:class=>"change"}
total_initial_investment_per(:mwh_electricity) 388.90{:class=>"change"}
costs_per_mw_heat
total_costs_per(:mw_heat) 621 K316 K{:class=>"change"}
fixed_costs_per(:mw_heat) 316 K316 K{:class=>"change"}
cost_of_capital_per(:mw_heat) 91,00091,000{:class=>"change"}
depreciation_costs_per(:mw_heat) 117 K117 K{:class=>"change"}
variable_costs_per(:mw_heat) 305 K0{:class=>"change"}
fuel_costs_per(:mw_heat) 119 K0{:class=>"change"}
co2_emissions_costs_per(:mw_heat) 163 K0{:class=>"change"}
captured_biogenic_co2_costs_per(:mw_heat) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:mw_heat) 108 K108 K{:class=>"change"}
variable_operation_and_maintenance_costs_per(:mw_heat) 23,1000{:class=>"change"}
total_initial_investment_per(:mw_heat) 4,083 K4,083 K{:class=>"change"}
costs_per_mwh_heat
total_costs_per(:mwh_heat) 137.90{:class=>"change"}
fixed_costs_per(:mwh_heat) 70.210{:class=>"change"}
cost_of_capital_per(:mwh_heat) 20.220{:class=>"change"}
depreciation_costs_per(:mwh_heat) 25.930{:class=>"change"}
variable_costs_per(:mwh_heat) 67.72NaN{:class=>"change"}
fuel_costs_per(:mwh_heat) 26.4NaN{:class=>"change"}
co2_emissions_costs_per(:mwh_heat) 36.18NaN{:class=>"change"}
captured_biogenic_co2_costs_per(:mwh_heat) 0NaN{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:mwh_heat) 24.060{:class=>"change"}
variable_operation_and_maintenance_costs_per(:mwh_heat) 5.13NaN{:class=>"change"}
total_initial_investment_per(:mwh_heat) 907.40{:class=>"change"}