energy_flexibility_wind_batteries_electricity
Present
0
0
0
Future
0
0
0
|
|
|
|
Details
Sector | energy |
Use | energetic |
Storage |
cost_per_mwh
400000.0
decay
0.0
volume
129.0
|
Node groups |
|
Used in Gqueries | |
Used in Inputs |
Node Summary
Method | Label | Present | Future | Unit |
---|---|---|---|---|
technical | ||||
input_capacity * number_of_units | Installed capacity | 0 | 0 | MW |
storage[:volume] * number_of_units | Total storage capacity | 0 | 0 | MWh |
1.0/electricity_input_conversion * electricity_output_conversion | Round trip efficiency | 85.0 | 0.0 | % |
cost | ||||
total_investment_over_lifetime_per(:mw_input_capacity) | Investment over lifetime per MW input | 645000 | 645000 | EUR / MW |
fixed_operation_and_maintenance_costs_per(:mw_input_capacity) | Fixed operation and maintenance costs | 6450 | 6450 | EUR / MW / year |
variable_operation_and_maintenance_costs_per_full_load_hour | Variable operation and maintenance costs | 0 | 0 | EUR / full load hour |
wacc | Weighted average cost of capital | 4.0 | 4.0 | % |
takes_part_in_ets | Do emissions have to be paid through the ETS? | false | false | boolean |
other | ||||
technical_lifetime | Technical lifetime | 15 | 15 | years |
All Attributes
Node Attributes | Present | Future | Change | Unit |
---|---|---|---|---|
operational | ||||
electricity_output_capacity | 100 | 100 | {:class=>"change"} | MWe |
heat_output_capacity | 0 | 0 | {:class=>"change"} | MWth |
hydrogen_output_capacity | 0 | 0 | {:class=>"change"} | MW |
free_co2_factor | 0 | 0 | {:class=>"change"} | |
ccs_capture_rate | - | - | {:class=>"change"} | |
construction_time | 0.125 | 0.125 | {:class=>"change"} | |
electrical_efficiency_when_using_coal | - | - | {:class=>"change"} | |
electrical_efficiency_when_using_wood_pellets | - | - | {:class=>"change"} | |
full_load_hours | 0 | 0 | {:class=>"change"} | |
households_supplied_per_unit | - | - | {:class=>"change"} | |
land_use_per_unit | - | - | {:class=>"change"} | |
takes_part_in_ets | 0 | 0 | {:class=>"change"} | yes=1 / no=0 |
technical_lifetime | 15 | 15 | {:class=>"change"} | year |
typical_input_capacity | 80 | 80 | {:class=>"change"} | MWinput |
output_capacity | - | - | {:class=>"change"} | MW |
input_efficiency | - | - | {:class=>"change"} | |
output_efficiency | - | - | {:class=>"change"} | |
cost | ||||
initial_investment | 0 | 0 | {:class=>"change"} | euro / unit |
ccs_investment | 0 | 0 | {:class=>"change"} | euro / unit |
cost_of_installing | 0 | 0 | {:class=>"change"} | euro / unit |
decommissioning_costs | 0 | 0 | {:class=>"change"} | euro / unit |
fixed_operation_and_maintenance_costs_per_year | 516 K | 516 K | {:class=>"change"} | euro / unit / year |
variable_operation_and_maintenance_costs_per_full_load_hour | 0 | 0 | {:class=>"change"} | euro / full load hour |
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour | 0 | 0 | {:class=>"change"} | euro / full load hour |
fixed_costs_per_mw_input_capacity | 0 | 0 | {:class=>"change"} | euro / MWinput |
costs_per_mj | - | - | {:class=>"change"} | |
wacc | 0.04 | 0.04 | {:class=>"change"} | |
profitability | - | - | {:class=>"change"} | profitable / unprofitable / conditionally_profitable |
profit_per_mwh_electricity | - | - | {:class=>"change"} | eur/MWh |
marginal_costs | 0 | 0 | {:class=>"change"} | euro / MWh |
max_consumption_price | 0 | 0 | {:class=>"change"} | euro / MWh |
merit_order | ||||
merit_order_full_load_hours | - | - | {:class=>"change"} | |
merit_order_capacity_factor | - | - | {:class=>"change"} | |
merit_order_position | - | - | {:class=>"change"} | |
security_of_supply | ||||
availability | 1 | 1 | {:class=>"change"} | |
part_load_operating_point | - | - | {:class=>"change"} | |
part_load_efficiency_penalty | - | - | {:class=>"change"} | |
forecasting_error | 0 | 0 | {:class=>"change"} | |
misc | ||||
demand_expected_value | 0 | 0 | {:class=>"change"} | |
excel_id | - | - | {:class=>"change"} | |
max_demand | - | - | {:class=>"change"} |