GQL Statement

estimated_peak_demand_factor = 0.0004;
estimated_peak_demand_factor * V(buildings_space_heater_district_heating_mt_steam_hot_water, "input_of_steam_hot_water / MJ_PER_MWH")

Result

2015 0.26 ms
0.0
MW
2050 0.03 ms
0.0
MW

Description

For the present and if time-resolved calculations are turned off
the hourly input curves are not available. In that case
we estimate peak demand by multiplying total demand (in MWh)
by a 'peak demand factor'. This factor is based on NL2015 dataset by
dividing the future demand peak in a blank scenario by the total demand

Characteristics

Groups
Unit MW
File path /app/tmp/etsource/gqueries/general/costs/heat_infrastructure/mt/general_support_queries/demand_peaks/buildings_district_heating_mt_demand_peak_estimate.gql

References

Gquery buildings_district_heating_mt_demand_peak
Gquery households_buildings_district_heating_mt_demand_peak