GQL Statement

estimated_peak_demand_factor = 0.0004392;
estimated_peak_demand_factor *
SUM(
  V(
    households_space_heater_district_heating_ht_steam_hot_water,
    households_water_heater_district_heating_ht_steam_hot_water,
    buildings_space_heater_district_heating_ht_steam_hot_water,
    "input_of_steam_hot_water / MJ_PER_MWH"
  )
)

Result

2015 0.15 ms
2,427.6815075000004
MW
2050 0.06 ms
2,143.44676930477
MW

Description

For the present and if time-resolved calculations are turned off
the hourly input curves are not available. In that case
we estimate peak demand by multiplying total demand (in MWh)
by a 'peak demand factor'. This factor is based on NL2015 dataset by
dividing the future demand peak in a blank scenario by the total demand

Characteristics

Groups
Unit MW
File path /app/tmp/etsource/gqueries/general/costs/heat_infrastructure/ht/general_support_queries/demand_peaks/households_buildings_district_heating_ht_demand_peak_estimate.gql

References

Gquery households_buildings_district_heating_ht_demand_peak