Present 0 0 0
Future 0 0 0
Edges 0 Outputs
Node MJ Type
agriculture_useful_demand_useable_heat 0 Share
100.0 %
Inputs Edges 0
77.78 %
Type MJ Node
Share 0 environment_earth_ambient_heat
22.22 %
Type MJ Node
Share 0 agriculture_final_demand_electricity
Edges 0 Outputs
Node MJ Type
agriculture_useful_demand_useable_heat 0 Share
100.0 %
Inputs Edges 0
77.78 %
Type MJ Node
Share 0 environment_earth_ambient_heat
22.22 %
Type MJ Node
Share 0 agriculture_final_demand_electricity

Details

Sector agriculture
Use energetic
Merit Order
group
weather/agriculture_heating
level
mv
subtype
generic
type
consumer
Node groups
  1. heat_production
  2. application_group
  3. mv_net_demand
  4. wacc_proven_tech
  5. costs_building_and_installations_agriculture
Used in Gqueries
  1. agriculture_heatpump_water_water_electricity_cop
  2. agriculture_heatpump_water_water_electricity_input_of_electricity
  3. agriculture_heatpump_water_water_electricity_number_of_units
  4. depreciation_costs_industrial_heat_pump_per_kw
  5. mv_agriculture_load_curve
Used in Inputs
  1. agriculture_heatpump_water_water_electricity_share
  2. efficiency_agriculture_heatpump_water_water_electricity
  3. investment_costs_electric_heat_pumps
Method Label Present Future Unit
technical
coefficient_of_performance Coefficient of Performance 4.5 4.5 COP
heat_output_capacity Heat capacity per unit 1.0 1.0 MW / unit
full_load_hours Full load hours 6,500 6,500 hour / year
cost
total_investment_over_lifetime_per(:plant) Investment over lifetime per plant 500 K 500 K EUR / unit
fixed_operation_and_maintenance_costs_per(:plant) Fixed operation and maintenance costs 5,000 5,000 EUR / unit / year
variable_operation_and_maintenance_costs_per(:full_load_hour) Variable operation and maintenance costs 0 0 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
technical_lifetime Technical lifetime 15 15 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 0 0 MWe
heat_output_capacity 1 1 0% MWth
hydrogen_output_capacity 0 0 MW
free_co2_factor 0 0
ccs_capture_rate - -
construction_time 0 0
electrical_efficiency_when_using_coal - -
electrical_efficiency_when_using_wood_pellets - -
full_load_hours 6,500 6,500 0%
households_supplied_per_unit - -
land_use_per_unit - -
takes_part_in_ets 0 0 yes=1 / no=0
technical_lifetime 15 15 0% year
typical_input_capacity - - MWinput
output_capacity - - MW
input_efficiency - -
output_efficiency - -
cost
initial_investment 500 K 500 K 0% euro / unit
ccs_investment 0 0 euro / unit
cost_of_installing 0 0 euro / unit
decommissioning_costs 0 0 euro / unit
fixed_operation_and_maintenance_costs_per_year 5,000 5,000 0% euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 0 0 euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 0 0 euro / full load hour
fixed_costs_per_mw_input_capacity - - euro / MWinput
costs_per_mj - -
wacc 0.04 0.04 0%
profitability - - profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity - - eur/MWh
marginal_costs - - euro / MWh
max_consumption_price - - euro / MWh
merit_order
merit_order_full_load_hours - -
merit_order_capacity_factor - -
merit_order_position - -
security_of_supply
availability 0.99 0.99 0%
part_load_operating_point - -
part_load_efficiency_penalty - -
forecasting_error - -
misc
demand_expected_value 0 0
excel_id - -
max_demand - -
Node Calculations Present Future Change Unit
demand
demand 0 0
preset_demand - -
demand_of_sustainable 0 0
weighted_carrier_cost_per_mj 0.001 0.001 -3%
weighted_carrier_co2_per_mj 0 0
sustainability_share 0.807 0.8 0%
final_demand 0 0
primary_demand 0 0
primary_demand_of_fossil 0 0
primary_demand_of_sustainable 0 0
technical
input_capacity 1 1 0%
electric_based_input_capacity - - MWinput
heat_based_input_capacity 1 1 0% MWinput
cooling_based_input_capacity - - MWinput
number_of_units 0 0
costs_per_plant
total_costs_per(:plant) 68,587.5 67,858.5 -1% euro / plant
fixed_costs_per(:plant) 48,333.3 48,333.3 0%
cost_of_capital_per(:plant) 10,000 10,000 0%
depreciation_costs_per(:plant) 33,333.3 33,333.3 0%
variable_costs_per(:plant) 20,254.1 19,525.2 -3%
fuel_costs_per(:plant) 20,254.1 19,525.2 -3%
co2_emissions_costs_per(:plant) 0 0
captured_biogenic_co2_costs_per(:plant) 0 0
fixed_operation_and_maintenance_costs_per(:plant) 5,000 5,000 0%
variable_operation_and_maintenance_costs_per(:plant) 0 0
total_initial_investment_per(:plant) 500 K 500 K 0%
costs_per_node
total_costs_per(:node) 0 0
fixed_costs_per(:node) 0 0
cost_of_capital_per(:node) 0 0
depreciation_costs_per(:node) 0 0
variable_costs_per(:node) 0 0
fuel_costs_per(:node) 0 0
co2_emissions_costs_per(:node) 0 0
captured_biogenic_co2_costs_per(:node) 0 0
fixed_operation_and_maintenance_costs_per(:node) 0 0
variable_operation_and_maintenance_costs_per(:node) 0 0
total_initial_investment_per(:node) 0 0
costs_per_mw_electricity
total_costs_per(:mw_electricity) 0 0
fixed_costs_per(:mw_electricity) 0 0
cost_of_capital_per(:mw_electricity) 0 0
depreciation_costs_per(:mw_electricity) 0 0
variable_costs_per(:mw_electricity) 0 0
fuel_costs_per(:mw_electricity) 0 0
co2_emissions_costs_per(:mw_electricity) NaN NaN
captured_biogenic_co2_costs_per(:mw_electricity) NaN NaN
fixed_operation_and_maintenance_costs_per(:mw_electricity) 0 0
variable_operation_and_maintenance_costs_per(:mw_electricity) NaN NaN
total_initial_investment_per(:mw_electricity) 0 0
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 0 0
fixed_costs_per(:mwh_electricity) 0 0
cost_of_capital_per(:mwh_electricity) 0 0
depreciation_costs_per(:mwh_electricity) 0 0
variable_costs_per(:mwh_electricity) 0 0
fuel_costs_per(:mwh_electricity) 0 0
co2_emissions_costs_per(:mwh_electricity) NaN NaN
captured_biogenic_co2_costs_per(:mwh_electricity) NaN NaN
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 0 0
variable_operation_and_maintenance_costs_per(:mwh_electricity) NaN NaN
total_initial_investment_per(:mwh_electricity) 0 0
costs_per_mw_heat
total_costs_per(:mw_heat) 68,587.5 67,858.5 -1%
fixed_costs_per(:mw_heat) 48,333.3 48,333.3 0%
cost_of_capital_per(:mw_heat) 10,000 10,000 0%
depreciation_costs_per(:mw_heat) 33,333.3 33,333.3 0%
variable_costs_per(:mw_heat) 20,254.1 19,525.2 -3%
fuel_costs_per(:mw_heat) 20,254.1 19,525.2 -3%
co2_emissions_costs_per(:mw_heat) 0 0
captured_biogenic_co2_costs_per(:mw_heat) 0 0
fixed_operation_and_maintenance_costs_per(:mw_heat) 5,000 5,000 0%
variable_operation_and_maintenance_costs_per(:mw_heat) 0 0
total_initial_investment_per(:mw_heat) 500 K 500 K 0%
costs_per_mwh_heat
total_costs_per(:mwh_heat) 10.55 10.44 -1%
fixed_costs_per(:mwh_heat) 7.44 7.44 0%
cost_of_capital_per(:mwh_heat) 1.54 1.54 0%
depreciation_costs_per(:mwh_heat) 5.13 5.13 0%
variable_costs_per(:mwh_heat) 3.12 3 -3%
fuel_costs_per(:mwh_heat) 3.12 3 -3%
co2_emissions_costs_per(:mwh_heat) 0 0
captured_biogenic_co2_costs_per(:mwh_heat) 0 0
fixed_operation_and_maintenance_costs_per(:mwh_heat) 0.769 0.769 0%
variable_operation_and_maintenance_costs_per(:mwh_heat) 0 0
total_initial_investment_per(:mwh_heat) 76.92 76.92 0%