Present 0 0 0
Future 0 0 0
Edges 0 Outputs
Node MJ Type
energy_hydrogen_transport_pipelines 0 Flexible
Reversed
81.3 %
18.7 %
Inputs Edges 0
0.0 %
100.0 %
Type MJ Node
Share 0 energy_treatment_natural_gas
Edges 0 Outputs
Node MJ Type
energy_hydrogen_transport_pipelines 0 Flexible
Reversed
81.3 %
18.7 %
Inputs Edges 0
0.0 %
100.0 %
Type MJ Node
Share 0 energy_treatment_natural_gas
Method Label Present Future Unit
technical
input_capacity * number_of_units Installed input capacity 0 0 MW
hydrogen_output_conversion Hydrogen output efficiency 81.3 81.3 %
full_load_hours Full load hours 8,322 0 hour / year
free_co2_factor CCS capture rate 0.0 0.0 %
cost
initial_investment_per(:mw_input_capacity) + cost_of_installing_per(:mw_input_capacity) + decommissioning_costs_per(:mw_input_capacity) Investment over lifetime per MW input 636229 636229 EUR / MW
ccs_investment_per(:mw_input_capacity) Additional initial investment for CCS 0 0 EUR / MW
fixed_operation_and_maintenance_costs_per(:mw_input_capacity) Fixed operation and maintenance costs 24390 24390 EUR / MW / year
variable_operation_and_maintenance_costs_per(:full_load_hour) Variable operation and maintenance costs 0 NaN EUR / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour Additional variable operation and maintenance costs for CCS 0 0 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? true true boolean
other
technical_lifetime Technical lifetime 25 25 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 0 0 MWe
heat_output_capacity 0 0 MWth
hydrogen_output_capacity 300 300 0% MW
free_co2_factor 0 0
ccs_capture_rate - -
construction_time 3 3 0%
electrical_efficiency_when_using_coal - -
electrical_efficiency_when_using_wood_pellets - -
full_load_hours 8,322 0 -100%
households_supplied_per_unit - -
land_use_per_unit - -
takes_part_in_ets 1 1 0% yes=1 / no=0
technical_lifetime 25 25 0% year
typical_input_capacity 369 369 0% MWinput
output_capacity - - MW
input_efficiency - -
output_efficiency - -
cost
initial_investment 222 M 222 M 0% euro / unit
ccs_investment 0 0 euro / unit
cost_of_installing 0 0 euro / unit
decommissioning_costs 12.77 M 12.77 M 0% euro / unit
fixed_operation_and_maintenance_costs_per_year 9,000 K 9,000 K 0% euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 0 0 euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 0 0 euro / full load hour
fixed_costs_per_mw_input_capacity - - euro / MWinput
costs_per_mj - -
wacc 0.04 0.04 0%
profitability - - profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity - - eur/MWh
marginal_costs - - euro / MWh
max_consumption_price - - euro / MWh
merit_order
merit_order_full_load_hours - -
merit_order_capacity_factor - -
merit_order_position - -
security_of_supply
availability 1 1 0%
part_load_operating_point - -
part_load_efficiency_penalty - -
forecasting_error - -
misc
demand_expected_value 0 0
excel_id - -
max_demand - -
Node Calculations Present Future Change Unit
demand
demand 0 0
preset_demand - -
demand_of_sustainable 0 0
weighted_carrier_cost_per_mj 0.005 0.005 0%
weighted_carrier_co2_per_mj 0.057 0.057 0%
sustainability_share 0 0
final_demand 0 0
primary_demand 0 0
primary_demand_of_fossil 0 0
primary_demand_of_sustainable 0 0
technical
input_capacity 369 369 0%
electric_based_input_capacity - - MWinput
heat_based_input_capacity - - MWinput
cooling_based_input_capacity - - MWinput
number_of_units 0 0
costs_per_plant
total_costs_per(:plant) 80.42 M 23.65 M -70% euro / plant
fixed_costs_per(:plant) 23.65 M 23.65 M 0%
cost_of_capital_per(:plant) 5,259 K 5,259 K 0%
depreciation_costs_per(:plant) 9,391 K 9,391 K 0%
variable_costs_per(:plant) 56.77 M 0 -100%
fuel_costs_per(:plant) 56.04 M 0 -100%
co2_emissions_costs_per(:plant) 731 K 0 -100%
captured_biogenic_co2_costs_per(:plant) 0 0
fixed_operation_and_maintenance_costs_per(:plant) 9,000 K 9,000 K 0%
variable_operation_and_maintenance_costs_per(:plant) 0 0
total_initial_investment_per(:plant) 222 M 222 M 0%
costs_per_node
total_costs_per(:node) 0 0
fixed_costs_per(:node) 0 0
cost_of_capital_per(:node) 0 0
depreciation_costs_per(:node) 0 0
variable_costs_per(:node) 0 0
fuel_costs_per(:node) 0 0
co2_emissions_costs_per(:node) 0 0
captured_biogenic_co2_costs_per(:node) 0 0
fixed_operation_and_maintenance_costs_per(:node) 0 0
variable_operation_and_maintenance_costs_per(:node) 0 0
total_initial_investment_per(:node) 0 0
costs_per_mw_electricity
total_costs_per(:mw_electricity) 0 0
fixed_costs_per(:mw_electricity) 0 0
cost_of_capital_per(:mw_electricity) 0 0
depreciation_costs_per(:mw_electricity) 0 0
variable_costs_per(:mw_electricity) 0 NaN
fuel_costs_per(:mw_electricity) 0 NaN
co2_emissions_costs_per(:mw_electricity) 0 NaN
captured_biogenic_co2_costs_per(:mw_electricity) NaN NaN
fixed_operation_and_maintenance_costs_per(:mw_electricity) 0 0
variable_operation_and_maintenance_costs_per(:mw_electricity) NaN NaN
total_initial_investment_per(:mw_electricity) 0 0
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 0 0
fixed_costs_per(:mwh_electricity) 0 0
cost_of_capital_per(:mwh_electricity) 0 0
depreciation_costs_per(:mwh_electricity) 0 0
variable_costs_per(:mwh_electricity) 0 NaN
fuel_costs_per(:mwh_electricity) 0 NaN
co2_emissions_costs_per(:mwh_electricity) 0 NaN
captured_biogenic_co2_costs_per(:mwh_electricity) NaN NaN
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 0 0
variable_operation_and_maintenance_costs_per(:mwh_electricity) NaN NaN
total_initial_investment_per(:mwh_electricity) 0 0
costs_per_mw_heat
total_costs_per(:mw_heat) 0 0
fixed_costs_per(:mw_heat) 0 0
cost_of_capital_per(:mw_heat) 0 0
depreciation_costs_per(:mw_heat) 0 0
variable_costs_per(:mw_heat) 0 NaN
fuel_costs_per(:mw_heat) 0 NaN
co2_emissions_costs_per(:mw_heat) 0 NaN
captured_biogenic_co2_costs_per(:mw_heat) NaN NaN
fixed_operation_and_maintenance_costs_per(:mw_heat) 0 0
variable_operation_and_maintenance_costs_per(:mw_heat) NaN NaN
total_initial_investment_per(:mw_heat) 0 0
costs_per_mwh_heat
total_costs_per(:mwh_heat) 0 0
fixed_costs_per(:mwh_heat) 0 0
cost_of_capital_per(:mwh_heat) 0 0
depreciation_costs_per(:mwh_heat) 0 0
variable_costs_per(:mwh_heat) 0 NaN
fuel_costs_per(:mwh_heat) 0 NaN
co2_emissions_costs_per(:mwh_heat) 0 NaN
captured_biogenic_co2_costs_per(:mwh_heat) NaN NaN
fixed_operation_and_maintenance_costs_per(:mwh_heat) 0 0
variable_operation_and_maintenance_costs_per(:mwh_heat) NaN NaN
total_initial_investment_per(:mwh_heat) 0 0