Present 16.77 B 16.77 B 16.77 B
Future 16.77 B 16.77 B 16.77 B
Edges 16.77 B Outputs
Node MJ Type
households_locally_available_electricity 2.85 B Share
Reversed
17.0 %
83.0 %
Inputs Edges 16.77 B
100.0 %
Type MJ Node
Share 16.77 B environment_sun_solar_radiation
Edges 16.77 B Outputs
Node MJ Type
households_locally_available_electricity 2.85 B Share
Reversed
17.0 %
83.0 %
Inputs Edges 16.77 B
100.0 %
Type MJ Node
Share 16.77 B environment_sun_solar_radiation

Details

Sector households
Use energetic
Merit Order
group
dynamic: solar_pv
level
lv
subtype
volatile
type
producer
Node groups
  1. electricity_production
  2. primary_energy_demand
  3. sustainable_production
  4. volatile_production
  5. lv_net_supply
  6. wacc_households
  7. costs_building_and_installations_households
  8. preset_demand
Used in Gqueries
  1. converter_group_power_plant_per_plant_type_solar_on_roof
  2. costs_of_solar_pv_households_in_overview_costs_of_electricity_production
  3. depreciation_costs_households_solar_panels_per_kw
  4. electricity_curtailment_flexible_curve
  5. energy_curtailment_solar_pv_electricity_peak_capacity
  6. energy_mix_capacity_per_panel_solar_pv
  7. etflex_households_investment_per_household
  8. etflex_households_monthly_energy_bill
  9. etflex_households_renewability_percentage_electricity_per_household
  10. factsheet_number_of_roof_solar_pv
  11. factsheet_supply_electricity_from_roof_solar
  12. factsheet_supply_electricity_from_roof_solar_households
  13. households_potential_electricity_production_of_solar_roof_pv
  14. households_solar_pv_curtailed_electricity_output_curve
  15. households_solar_pv_electricity_output_curve
  16. households_solar_pv_installed_capacity
  17. households_solar_pv_production_after_curtailment
  18. households_solar_pv_production_before_curtailment
  19. households_solar_pv_solar_radiation
  20. households_solar_pv_solar_radiation_delta_in_investment_cost_table
  21. households_solar_pv_solar_radiation_future_in_investment_cost_table
  22. households_solar_pv_solar_radiation_present_in_investment_cost_table
  23. investment_for_solar_pv_households_in_overview_costs_of_electricity_production
  24. land_use_solar_wind_solar_pv_households_capacity_per_unit
  25. land_use_solar_wind_solar_pv_households_electricity_output
  26. land_use_solar_wind_solar_pv_households_full_load_hours
  27. land_use_solar_wind_solar_pv_households_installed_capacity
  28. land_use_solar_wind_solar_pv_households_land_use_per_unit
  29. land_use_solar_wind_solar_pv_households_number_of_units
  30. loss_of_load_expectation
  31. maximum_number_solar_pv_panels
  32. merit_order_households_solar_pv_solar_radiation_availability_in_merit_order_table
  33. merit_order_households_solar_pv_solar_radiation_capacity_in_merit_order_table
  34. merit_order_households_solar_pv_solar_radiation_full_load_hours_in_merit_order_table
  35. merit_order_households_solar_pv_solar_radiation_load_factor_in_merit_order_table
  36. merit_order_households_solar_pv_solar_radiation_operating_costs_in_merit_order_table
  37. solar_panels_in_roof_area_for_pv_in_households
  38. solar_panels_in_source_of_electricity_in_households
  39. solar_pv_total_curtailed_electricity_curve
  40. total_cost_of_households_solar_pv_solar_radiation
Used in Inputs
  1. capacity_of_households_solar_pv_solar_radiation
  2. curtailment_of_households_solar_pv_solar_radiation
  3. efficiency_energy_power_solar_pv_solar_radiation
  4. flh_of_solar_pv_solar_radiation
  5. flh_of_solar_pv_solar_radiation_user_curve
  6. investment_costs_solar_solar_panels
  7. settings_weather_curve_set
Method Label Present Future Unit
technical
electricity_output_capacity * number_of_units Installed electrical capacity 913.5 913.5 MW
electricity_output_capacity Capacity per unit 0 0 MW
electricity_output_conversion Electrical efficiency 17.0 17.0 %
full_load_hours Full load hours 867 867 hour / year
cost
total_investment_over_lifetime_per(:mw_electricity) Investment over lifetime per MW 1300000 1300000 EUR / MW
fixed_operation_and_maintenance_costs_per(:mw_electricity) Fixed operation and maintenance costs 16985 16985 EUR / MW / year
variable_operation_and_maintenance_costs_per_full_load_hour Variable operation and maintenance costs 0 0 EUR / full load hour
wacc Weighted average cost of capital 2.0 2.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
land_use_per_unit / electricity_output_capacity Land use 0.006 0.006 km2 / MW
technical_lifetime Technical lifetime 25 25 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 00{:class=>"change"}MWe
heat_output_capacity 00{:class=>"change"}MWth
hydrogen_output_capacity 00{:class=>"change"}MW
free_co2_factor 00{:class=>"change"}
ccs_capture_rate --{:class=>"change"}
construction_time 0.30.3{:class=>"change"}
electrical_efficiency_when_using_coal --{:class=>"change"}
electrical_efficiency_when_using_wood_pellets --{:class=>"change"}
full_load_hours 867867{:class=>"change"}
households_supplied_per_unit --{:class=>"change"}
land_use_per_unit 00{:class=>"change"}
takes_part_in_ets 00{:class=>"change"}yes=1 / no=0
technical_lifetime 2525{:class=>"change"}year
typical_input_capacity --{:class=>"change"}MWinput
output_capacity --{:class=>"change"}MW
input_efficiency --{:class=>"change"}
output_efficiency --{:class=>"change"}
cost
initial_investment 217.3217.3{:class=>"change"}euro / unit
ccs_investment 00{:class=>"change"}euro / unit
cost_of_installing 136.3136.3{:class=>"change"}euro / unit
decommissioning_costs 00{:class=>"change"}euro / unit
fixed_operation_and_maintenance_costs_per_year 4.624.62{:class=>"change"}euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 00{:class=>"change"}euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 00{:class=>"change"}euro / full load hour
fixed_costs_per_mw_input_capacity --{:class=>"change"}euro / MWinput
costs_per_mj --{:class=>"change"}
wacc 0.020.02{:class=>"change"}
profitability --{:class=>"change"}profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity --{:class=>"change"}eur/MWh
marginal_costs 00{:class=>"change"}euro / MWh
max_consumption_price 00{:class=>"change"}euro / MWh
merit_order
merit_order_full_load_hours --{:class=>"change"}
merit_order_capacity_factor --{:class=>"change"}
merit_order_position --{:class=>"change"}
security_of_supply
availability 0.980.98{:class=>"change"}
part_load_operating_point --{:class=>"change"}
part_load_efficiency_penalty --{:class=>"change"}
forecasting_error --{:class=>"change"}
misc
demand_expected_value --{:class=>"change"}
excel_id --{:class=>"change"}
max_demand --{:class=>"change"}
Node Calculations Present Future Change Unit
demand
demand 16.77 B16.77 B{:class=>"change"}
preset_demand 16.77 B16.77 B{:class=>"change"}
demand_of_sustainable 00{:class=>"change"}
weighted_carrier_cost_per_mj 00{:class=>"change"}
weighted_carrier_co2_per_mj 00{:class=>"change"}
sustainability_share 11{:class=>"change"}
final_demand 00{:class=>"change"}
primary_demand 2.85 B2.85 B{:class=>"change"}
primary_demand_of_fossil 00{:class=>"change"}
primary_demand_of_sustainable 2.85 B2.85 B{:class=>"change"}
primary_demand_of_electricity 2.85 B2.85 B{:class=>"change"}
technical
input_capacity 0.0020.002{:class=>"change"}
electric_based_input_capacity 0.0020.002{:class=>"change"}MWinput
heat_based_input_capacity --{:class=>"change"}MWinput
cooling_based_input_capacity --{:class=>"change"}MWinput
number_of_units 3,359 K3,359 K{:class=>"change"}
costs_per_plant
total_costs_per(:plant) 22.3422.34{:class=>"change"}euro / plant
fixed_costs_per(:plant) 22.3422.34{:class=>"change"}
cost_of_capital_per(:plant) 3.583.58{:class=>"change"}
depreciation_costs_per(:plant) 14.1414.14{:class=>"change"}
variable_costs_per(:plant) 00{:class=>"change"}
fuel_costs_per(:plant) 00{:class=>"change"}
co2_emissions_costs_per(:plant) 00{:class=>"change"}
captured_biogenic_co2_costs_per(:plant) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:plant) 4.624.62{:class=>"change"}
variable_operation_and_maintenance_costs_per(:plant) 00{:class=>"change"}
total_initial_investment_per(:plant) 353.6353.6{:class=>"change"}
costs_per_node
total_costs_per(:node) 75.04 M75.04 M{:class=>"change"}
fixed_costs_per(:node) 75.04 M75.04 M{:class=>"change"}
cost_of_capital_per(:node) 12.02 M12.02 M{:class=>"change"}
depreciation_costs_per(:node) 47.5 M47.5 M{:class=>"change"}
variable_costs_per(:node) 00{:class=>"change"}
fuel_costs_per(:node) 00{:class=>"change"}
co2_emissions_costs_per(:node) 00{:class=>"change"}
captured_biogenic_co2_costs_per(:node) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:node) 15.52 M15.52 M{:class=>"change"}
variable_operation_and_maintenance_costs_per(:node) 00{:class=>"change"}
total_initial_investment_per(:node) 1.19 B1.19 B{:class=>"change"}
costs_per_mw_electricity
total_costs_per(:mw_electricity) 82,141.382,141.3{:class=>"change"}
fixed_costs_per(:mw_electricity) 82,141.382,141.3{:class=>"change"}
cost_of_capital_per(:mw_electricity) 13,15613,156{:class=>"change"}
depreciation_costs_per(:mw_electricity) 52,00052,000{:class=>"change"}
variable_costs_per(:mw_electricity) 00{:class=>"change"}
fuel_costs_per(:mw_electricity) 00{:class=>"change"}
co2_emissions_costs_per(:mw_electricity) 00{:class=>"change"}
captured_biogenic_co2_costs_per(:mw_electricity) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:mw_electricity) 16,985.316,985.3{:class=>"change"}
variable_operation_and_maintenance_costs_per(:mw_electricity) 00{:class=>"change"}
total_initial_investment_per(:mw_electricity) 1,300 K1,300 K{:class=>"change"}
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 94.7494.74{:class=>"change"}
fixed_costs_per(:mwh_electricity) 94.7494.74{:class=>"change"}
cost_of_capital_per(:mwh_electricity) 15.1715.17{:class=>"change"}
depreciation_costs_per(:mwh_electricity) 59.9859.98{:class=>"change"}
variable_costs_per(:mwh_electricity) 00{:class=>"change"}
fuel_costs_per(:mwh_electricity) 00{:class=>"change"}
co2_emissions_costs_per(:mwh_electricity) 00{:class=>"change"}
captured_biogenic_co2_costs_per(:mwh_electricity) 00{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 19.5919.59{:class=>"change"}
variable_operation_and_maintenance_costs_per(:mwh_electricity) 00{:class=>"change"}
total_initial_investment_per(:mwh_electricity) 1,499.41,499.4{:class=>"change"}
costs_per_mw_heat
total_costs_per(:mw_heat) 00{:class=>"change"}
fixed_costs_per(:mw_heat) 00{:class=>"change"}
cost_of_capital_per(:mw_heat) 00{:class=>"change"}
depreciation_costs_per(:mw_heat) 00{:class=>"change"}
variable_costs_per(:mw_heat) NaNNaN{:class=>"change"}
fuel_costs_per(:mw_heat) NaNNaN{:class=>"change"}
co2_emissions_costs_per(:mw_heat) NaNNaN{:class=>"change"}
captured_biogenic_co2_costs_per(:mw_heat) NaNNaN{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:mw_heat) 00{:class=>"change"}
variable_operation_and_maintenance_costs_per(:mw_heat) NaNNaN{:class=>"change"}
total_initial_investment_per(:mw_heat) 00{:class=>"change"}
costs_per_mwh_heat
total_costs_per(:mwh_heat) 00{:class=>"change"}
fixed_costs_per(:mwh_heat) 00{:class=>"change"}
cost_of_capital_per(:mwh_heat) 00{:class=>"change"}
depreciation_costs_per(:mwh_heat) 00{:class=>"change"}
variable_costs_per(:mwh_heat) NaNNaN{:class=>"change"}
fuel_costs_per(:mwh_heat) NaNNaN{:class=>"change"}
co2_emissions_costs_per(:mwh_heat) NaNNaN{:class=>"change"}
captured_biogenic_co2_costs_per(:mwh_heat) NaNNaN{:class=>"change"}
fixed_operation_and_maintenance_costs_per(:mwh_heat) 00{:class=>"change"}
variable_operation_and_maintenance_costs_per(:mwh_heat) NaNNaN{:class=>"change"}
total_initial_investment_per(:mwh_heat) 00{:class=>"change"}