Present 1.42 B 1.42 B 1.42 B
Future 1.42 B 1.42 B 1.42 B
Edges 1.42 B Outputs
0.0 %
Node MJ Type
households_space_heater_heatpump_ground_water_electricity_aggregator 1.42 B Share
100.0 %
Inputs Edges 1.42 B
79.17 %
Type MJ Node
Share 1.12 B environment_earth_ambient_heat
20.83 %
Type MJ Node
Share 294.89 M households_final_demand_for_space_heating_electricity
Edges 1.42 B Outputs
0.0 %
Node MJ Type
households_space_heater_heatpump_ground_water_electricity_aggregator 1.42 B Share
100.0 %
Inputs Edges 1.42 B
79.17 %
Type MJ Node
Share 1.12 B environment_earth_ambient_heat
20.83 %
Type MJ Node
Share 294.89 M households_final_demand_for_space_heating_electricity

Details

Sector households
Use energetic
Fever (Heat)
defer_for
4
group
space_heating
share_in_group
0.005201376973657282
technology_curve_type
tech_constant
type
producer
Storage
cost_per_mwh
154736.8
decay
0.0
volume
0.0
Node groups
  1. demand_driven
  2. heat_production
  3. etmoses
  4. merit_household_space_heating_producers
  5. application_group
  6. aggregator_producer
  7. lv_net_demand
  8. wacc_households
  9. merit_order_csv_include
  10. costs_building_and_installations_households
  11. lt_delivery_system_households
Used in Gqueries
  1. etflex_households_investment_per_household
  2. etflex_households_renewability_percentage_heat_per_household
  3. households_space_heater_heatpump_ground_water_electricity_cop
  4. households_space_heater_heatpump_ground_water_electricity_delta_in_investment_cost_table
  5. households_space_heater_heatpump_ground_water_electricity_future_in_investment_cost_table
  6. households_space_heater_heatpump_ground_water_electricity_input_of_electricity
  7. households_space_heater_heatpump_ground_water_electricity_number_of_units
  8. households_space_heater_heatpump_ground_water_electricity_present_in_investment_cost_table
  9. total_cost_of_households_space_heater_heatpump_ground_water_electricity
  10. turk_full_load_hours_of_households_space_heater_heatpump_ground_water_electricity
  11. turk_number_of_households_space_heater_heatpump_ground_water_electricity
  12. turk_number_of_units_of_households_space_heater_heatpump_ground_water_electricity
  13. user_sortable_households_space_heater_heatpump_ground_water_electricity_capacity
Used in Inputs
  1. efficiency_households_space_heater_heatpump_ground_water_electricity
  2. households_heater_heatpump_ground_water_electricity_heat_output_capacity
  3. households_heater_heatpump_ground_water_electricity_share
  4. investment_costs_electric_heat_pumps
  5. investment_costs_households_storage_space_heating
Method Label Present Future Unit
technical
coefficient_of_performance Coefficient of Performance 4.8 4.8 COP
heat_output_capacity Heat capacity per unit 0.01 0.01 MW / unit
full_load_hours Full load hours 996.2 996.2 hour / year
cost
total_investment_over_lifetime_per(:plant) Investment over lifetime per plant 13,904 13,904 EUR / unit
fixed_operation_and_maintenance_costs_per(:plant) Fixed operation and maintenance costs 100 100 EUR / unit / year
variable_operation_and_maintenance_costs_per(:full_load_hour) Variable operation and maintenance costs 0 0 EUR / full load hour
wacc Weighted average cost of capital 2.0 2.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
technical_lifetime Technical lifetime 15 15 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 0 0 MWe
heat_output_capacity 0.01 0.01 0% MWth
hydrogen_output_capacity 0 0 MW
free_co2_factor 0 0
ccs_capture_rate - -
construction_time 0 0
electrical_efficiency_when_using_coal - -
electrical_efficiency_when_using_wood_pellets - -
full_load_hours 996.2 996.2 0%
households_supplied_per_unit 1 1 0%
land_use_per_unit - -
takes_part_in_ets 0 0 yes=1 / no=0
technical_lifetime 15 15 0% year
typical_input_capacity - - MWinput
output_capacity - - MW
input_efficiency - -
output_efficiency - -
cost
initial_investment 13,904 13,904 0% euro / unit
ccs_investment 0 0 euro / unit
cost_of_installing 0 0 euro / unit
decommissioning_costs 0 0 euro / unit
fixed_operation_and_maintenance_costs_per_year 100 100 0% euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 0 0 euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 0 0 euro / full load hour
fixed_costs_per_mw_input_capacity - - euro / MWinput
costs_per_mj - -
wacc 0.02 0.02 0%
profitability - - profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity - - eur/MWh
marginal_costs - - euro / MWh
max_consumption_price - - euro / MWh
merit_order
merit_order_full_load_hours - -
merit_order_capacity_factor - -
merit_order_position - -
security_of_supply
availability 0 0
part_load_operating_point - -
part_load_efficiency_penalty - -
forecasting_error - -
misc
demand_expected_value 1.42 B 1.42 B 0%
excel_id - -
max_demand - -
Node Calculations Present Future Change Unit
demand
demand 1.42 B 1.42 B 0%
preset_demand - -
demand_of_sustainable 0 0
weighted_carrier_cost_per_mj 0.001 0.001 -3%
weighted_carrier_co2_per_mj 0 0
sustainability_share 0.825 0.819 0%
final_demand 294.89 M 294.89 M 0%
primary_demand 565.48 M 572.03 M 1%
primary_demand_of_fossil 98.75 M 103.33 M 4%
primary_demand_of_sustainable 466.73 M 468.7 M 0%
primary_demand_of_wood_pellets 13.59 M 468 K -96%
primary_demand_of_biogas 4,019 K 5,248 K 30%
primary_demand_of_electricity 34.28 M 28.05 M -18%
primary_demand_of_coal 279.09 M 243.57 M -12%
primary_demand_of_lng 2,405 K 3,933 K 63%
primary_demand_of_natural_gas 139.35 M 227.93 M 63%
primary_demand_of_biogenic_waste 14.86 M 17.38 M 16%
primary_demand_of_non_biogenic_waste 12.16 M 14.22 M 16%
primary_demand_of_uranium_oxide 39.83 M 28.78 M -27%
primary_demand_of_imported_electricity 25.89 M 25,076.3 -99%
technical
input_capacity 0.01 0.01 0%
electric_based_input_capacity - - MWinput
heat_based_input_capacity 0.01 0.01 0% MWinput
cooling_based_input_capacity - - MWinput
number_of_units 39,467.9 39,467.9 0%
costs_per_plant
total_costs_per(:plant) 1,194.1 1,193.1 0% euro / plant
fixed_costs_per(:plant) 1,166 1,166 0%
cost_of_capital_per(:plant) 139 139 0%
depreciation_costs_per(:plant) 926.9 926.9 0%
variable_costs_per(:plant) 28.09 27.08 -3%
fuel_costs_per(:plant) 28.09 27.08 -3%
co2_emissions_costs_per(:plant) 0 0
captured_biogenic_co2_costs_per(:plant) 0 0
fixed_operation_and_maintenance_costs_per(:plant) 100 100 0%
variable_operation_and_maintenance_costs_per(:plant) 0 0
total_initial_investment_per(:plant) 13,904 13,904 0%
costs_per_node
total_costs_per(:node) 47.13 M 47.09 M 0%
fixed_costs_per(:node) 46.02 M 46.02 M 0%
cost_of_capital_per(:node) 5,488 K 5,488 K 0%
depreciation_costs_per(:node) 36.58 M 36.58 M 0%
variable_costs_per(:node) 1,108 K 1,069 K -3%
fuel_costs_per(:node) 1,108 K 1,069 K -3%
co2_emissions_costs_per(:node) 0 0
captured_biogenic_co2_costs_per(:node) 0 0
fixed_operation_and_maintenance_costs_per(:node) 3,947 K 3,947 K 0%
variable_operation_and_maintenance_costs_per(:node) 0 0
total_initial_investment_per(:node) 548.76 M 548.76 M 0%
costs_per_mw_electricity
total_costs_per(:mw_electricity) 0 0
fixed_costs_per(:mw_electricity) 0 0
cost_of_capital_per(:mw_electricity) 0 0
depreciation_costs_per(:mw_electricity) 0 0
variable_costs_per(:mw_electricity) 0 0
fuel_costs_per(:mw_electricity) 0 0
co2_emissions_costs_per(:mw_electricity) NaN NaN
captured_biogenic_co2_costs_per(:mw_electricity) NaN NaN
fixed_operation_and_maintenance_costs_per(:mw_electricity) 0 0
variable_operation_and_maintenance_costs_per(:mw_electricity) NaN NaN
total_initial_investment_per(:mw_electricity) 0 0
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 0 0
fixed_costs_per(:mwh_electricity) 0 0
cost_of_capital_per(:mwh_electricity) 0 0
depreciation_costs_per(:mwh_electricity) 0 0
variable_costs_per(:mwh_electricity) 0 0
fuel_costs_per(:mwh_electricity) 0 0
co2_emissions_costs_per(:mwh_electricity) NaN NaN
captured_biogenic_co2_costs_per(:mwh_electricity) NaN NaN
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 0 0
variable_operation_and_maintenance_costs_per(:mwh_electricity) NaN NaN
total_initial_investment_per(:mwh_electricity) 0 0
costs_per_mw_heat
total_costs_per(:mw_heat) 119 K 119 K 0%
fixed_costs_per(:mw_heat) 117 K 117 K 0%
cost_of_capital_per(:mw_heat) 13,904 13,904 0%
depreciation_costs_per(:mw_heat) 92,693.3 92,693.3 0%
variable_costs_per(:mw_heat) 2,808.6 2,707.8 -3%
fuel_costs_per(:mw_heat) 2,808.6 2,707.8 -3%
co2_emissions_costs_per(:mw_heat) 0 0
captured_biogenic_co2_costs_per(:mw_heat) 0 0
fixed_operation_and_maintenance_costs_per(:mw_heat) 10,000 10,000 0%
variable_operation_and_maintenance_costs_per(:mw_heat) 0 0
total_initial_investment_per(:mw_heat) 1,390 K 1,390 K 0%
costs_per_mwh_heat
total_costs_per(:mwh_heat) 119.9 119.8 0%
fixed_costs_per(:mwh_heat) 117 117 0%
cost_of_capital_per(:mwh_heat) 13.96 13.96 0%
depreciation_costs_per(:mwh_heat) 93.05 93.05 0%
variable_costs_per(:mwh_heat) 2.82 2.72 -3%
fuel_costs_per(:mwh_heat) 2.82 2.72 -3%
co2_emissions_costs_per(:mwh_heat) 0 0
captured_biogenic_co2_costs_per(:mwh_heat) 0 0
fixed_operation_and_maintenance_costs_per(:mwh_heat) 10.04 10.04 0%
variable_operation_and_maintenance_costs_per(:mwh_heat) 0 0
total_initial_investment_per(:mwh_heat) 1,395.7 1,395.7 0%