Present 9.42 B 9.42 B 9.42 B
Future 9.42 B 9.42 B 9.42 B
Edges 9.42 B Outputs
20.0 %
Node MJ Type
households_space_heater_network_gas_aggregator 7.54 B Share
80.0 %
Inputs Edges 9.42 B
100.0 %
Type MJ Node
Share 9.42 B households_final_demand_for_space_heating_network_gas
Edges 9.42 B Outputs
20.0 %
Node MJ Type
households_space_heater_network_gas_aggregator 7.54 B Share
80.0 %
Inputs Edges 9.42 B
100.0 %
Type MJ Node
Share 9.42 B households_final_demand_for_space_heating_network_gas

Details

Sector households
Use energetic
Fever (Heat)
defer_for
4
group
space_heating
share_in_group
0.01679772869091546
technology_curve_type
tech_day_night
type
producer
Network Gas
profile
self: heat_output_curve
type
consumer
Node groups
  1. demand_driven
  2. heat_production
  3. etmoses
  4. application_group
  5. aggregator_producer
  6. wacc_households
  7. costs_building_and_installations_households
  8. ht_delivery_system_households
Used in Gqueries
  1. households_space_heater_network_gas_delta_in_investment_cost_table
  2. households_space_heater_network_gas_future_in_investment_cost_table
  3. households_space_heater_network_gas_present_in_investment_cost_table
  4. number_of_residences_removed_from_natural_gas
  5. total_cost_of_households_space_heater_network_gas
  6. turk_full_load_hours_of_households_space_heater_network_gas
  7. turk_number_of_households_space_heater_network_gas
  8. turk_number_of_units_of_households_space_heater_network_gas
  9. user_sortable_households_space_heater_network_gas_capacity
Used in Inputs
  1. efficiency_households_space_heater_network_gas
  2. households_heater_network_gas_heat_output_capacity
  3. households_heater_network_gas_share
Method Label Present Future Unit
technical
heat_output_conversion Heat efficiency (LHV) 80.0 80.0 %
heat_output_capacity Heat capacity per unit 0.022 0.022 MW / unit
full_load_hours Full load hours 746.7 746.7 hour / year
cost
total_investment_over_lifetime_per(:plant) Investment over lifetime per plant 1,300 1,300 EUR / unit
fixed_operation_and_maintenance_costs_per(:plant) Fixed operation and maintenance costs 85 85 EUR / unit / year
variable_operation_and_maintenance_costs_per(:full_load_hour) Variable operation and maintenance costs 0 0 EUR / full load hour
wacc Weighted average cost of capital 2.0 2.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
technical_lifetime Technical lifetime 15 15 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 0 0 MWe
heat_output_capacity 0.022 0.022 0% MWth
hydrogen_output_capacity 0 0 MW
free_co2_factor 0 0
ccs_capture_rate - -
construction_time 0 0
electrical_efficiency_when_using_coal - -
electrical_efficiency_when_using_wood_pellets - -
full_load_hours 746.7 746.7 0%
households_supplied_per_unit 1 1 0%
land_use_per_unit - -
takes_part_in_ets 0 0 yes=1 / no=0
technical_lifetime 15 15 0% year
typical_input_capacity - - MWinput
output_capacity - - MW
input_efficiency - -
output_efficiency - -
cost
initial_investment 1,300 1,300 0% euro / unit
ccs_investment 0 0 euro / unit
cost_of_installing 0 0 euro / unit
decommissioning_costs 0 0 euro / unit
fixed_operation_and_maintenance_costs_per_year 85 85 0% euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 0 0 euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 0 0 euro / full load hour
fixed_costs_per_mw_input_capacity - - euro / MWinput
costs_per_mj - -
wacc 0.02 0.02 0%
profitability - - profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity - - eur/MWh
marginal_costs - - euro / MWh
max_consumption_price - - euro / MWh
merit_order
merit_order_full_load_hours - -
merit_order_capacity_factor - -
merit_order_position - -
security_of_supply
availability 0 0
part_load_operating_point - -
part_load_efficiency_penalty - -
forecasting_error - -
misc
demand_expected_value 9.42 B 9.42 B 0%
excel_id - -
max_demand - -
Node Calculations Present Future Change Unit
demand
demand 9.42 B 9.42 B 0%
preset_demand - -
demand_of_sustainable 0 0
weighted_carrier_cost_per_mj 0.005 0.005 0%
weighted_carrier_co2_per_mj 0.056 0.056 0%
sustainability_share 0.003 0.003 0%
final_demand 9.42 B 9.42 B 0%
primary_demand 9.57 B 9.57 B 0%
primary_demand_of_fossil 9.53 B 9.53 B 0%
primary_demand_of_sustainable 33.37 M 33.37 M 0%
primary_demand_of_biogas 33.07 M 33.07 M 0%
primary_demand_of_lng 161.72 M 161.72 M 0%
primary_demand_of_natural_gas 9.37 B 9.37 B 0%
technical
input_capacity 0.027 0.027 0%
electric_based_input_capacity - - MWinput
heat_based_input_capacity 0.027 0.027 0% MWinput
cooling_based_input_capacity - - MWinput
number_of_units 127 K 127 K 0%
costs_per_plant
total_costs_per(:plant) 562.7 562.7 0% euro / plant
fixed_costs_per(:plant) 184.7 184.7 0%
cost_of_capital_per(:plant) 13 13 0%
depreciation_costs_per(:plant) 86.67 86.67 0%
variable_costs_per(:plant) 378 378 0%
fuel_costs_per(:plant) 378 378 0%
co2_emissions_costs_per(:plant) 0 0
captured_biogenic_co2_costs_per(:plant) 0 0
fixed_operation_and_maintenance_costs_per(:plant) 85 85 0%
variable_operation_and_maintenance_costs_per(:plant) 0 0
total_initial_investment_per(:plant) 1,300 1,300 0%
costs_per_node
total_costs_per(:node) 71.72 M 71.72 M 0%
fixed_costs_per(:node) 23.54 M 23.54 M 0%
cost_of_capital_per(:node) 1,657 K 1,657 K 0%
depreciation_costs_per(:node) 11.05 M 11.05 M 0%
variable_costs_per(:node) 48.18 M 48.18 M 0%
fuel_costs_per(:node) 48.18 M 48.18 M 0%
co2_emissions_costs_per(:node) 0 0
captured_biogenic_co2_costs_per(:node) 0 0
fixed_operation_and_maintenance_costs_per(:node) 10.83 M 10.83 M 0%
variable_operation_and_maintenance_costs_per(:node) 0 0
total_initial_investment_per(:node) 165.7 M 165.7 M 0%
costs_per_mw_electricity
total_costs_per(:mw_electricity) 0 0
fixed_costs_per(:mw_electricity) 0 0
cost_of_capital_per(:mw_electricity) 0 0
depreciation_costs_per(:mw_electricity) 0 0
variable_costs_per(:mw_electricity) 0 0
fuel_costs_per(:mw_electricity) 0 0
co2_emissions_costs_per(:mw_electricity) NaN NaN
captured_biogenic_co2_costs_per(:mw_electricity) NaN NaN
fixed_operation_and_maintenance_costs_per(:mw_electricity) 0 0
variable_operation_and_maintenance_costs_per(:mw_electricity) NaN NaN
total_initial_investment_per(:mw_electricity) 0 0
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 0 0
fixed_costs_per(:mwh_electricity) 0 0
cost_of_capital_per(:mwh_electricity) 0 0
depreciation_costs_per(:mwh_electricity) 0 0
variable_costs_per(:mwh_electricity) 0 0
fuel_costs_per(:mwh_electricity) 0 0
co2_emissions_costs_per(:mwh_electricity) NaN NaN
captured_biogenic_co2_costs_per(:mwh_electricity) NaN NaN
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 0 0
variable_operation_and_maintenance_costs_per(:mwh_electricity) NaN NaN
total_initial_investment_per(:mwh_electricity) 0 0
costs_per_mw_heat
total_costs_per(:mw_heat) 25,576.4 25,576.4 0%
fixed_costs_per(:mw_heat) 8,393.9 8,393.9 0%
cost_of_capital_per(:mw_heat) 590.9 590.9 0%
depreciation_costs_per(:mw_heat) 3,939.4 3,939.4 0%
variable_costs_per(:mw_heat) 17,182.5 17,182.5 0%
fuel_costs_per(:mw_heat) 17,182.5 17,182.5 0%
co2_emissions_costs_per(:mw_heat) 0 0
captured_biogenic_co2_costs_per(:mw_heat) 0 0
fixed_operation_and_maintenance_costs_per(:mw_heat) 3,863.6 3,863.6 0%
variable_operation_and_maintenance_costs_per(:mw_heat) 0 0
total_initial_investment_per(:mw_heat) 59,090.9 59,090.9 0%
costs_per_mwh_heat
total_costs_per(:mwh_heat) 34.25 34.25 0%
fixed_costs_per(:mwh_heat) 11.24 11.24 0%
cost_of_capital_per(:mwh_heat) 0.791 0.791 0%
depreciation_costs_per(:mwh_heat) 5.28 5.28 0%
variable_costs_per(:mwh_heat) 23.01 23.01 0%
fuel_costs_per(:mwh_heat) 23.01 23.01 0%
co2_emissions_costs_per(:mwh_heat) 0 0
captured_biogenic_co2_costs_per(:mwh_heat) 0 0
fixed_operation_and_maintenance_costs_per(:mwh_heat) 5.17 5.17 0%
variable_operation_and_maintenance_costs_per(:mwh_heat) 0 0
total_initial_investment_per(:mwh_heat) 79.13 79.13 0%