Present 1.75 B 1.75 B 1.75 B
Future 1.75 B 1.75 B 1.75 B
Edges 1.75 B Outputs
33.0 %
Node MJ Type
households_water_heater_network_gas_aggregator 1.17 B Share
67.0 %
Inputs Edges 1.75 B
100.0 %
Type MJ Node
Share 1.75 B households_final_demand_for_hot_water_network_gas
Edges 1.75 B Outputs
33.0 %
Node MJ Type
households_water_heater_network_gas_aggregator 1.17 B Share
67.0 %
Inputs Edges 1.75 B
100.0 %
Type MJ Node
Share 1.75 B households_final_demand_for_hot_water_network_gas

Details

Sector households
Use energetic
Fever (Heat)
group
households_hot_water
share_in_group
0.02517801433543398
technology_curve_type
default
type
producer
Network Gas
profile
self: heat_output_curve
type
consumer
Node groups
  1. demand_driven
  2. heat_production
  3. etmoses
  4. application_group
  5. aggregator_producer
  6. wacc_households
  7. costs_building_and_installations_households
Used in Gqueries
  1. biggest_water_heater_share_name
  2. biggest_water_heater_share_value
  3. total_cost_of_households_water_heater_network_gas
  4. turk_full_load_hours_of_households_water_heater_network_gas
  5. turk_number_of_units_of_households_water_heater_network_gas
Used in Inputs
  1. households_heater_network_gas_heat_output_capacity
  2. households_heater_network_gas_share
Method Label Present Future Unit
technical
heat_output_conversion Heat efficiency (LHV) 67.0 67.0 %
heat_output_capacity Heat capacity per unit 0.024 0.024 MW / unit
full_load_hours Full load hours 71.12 71.12 hour / year
cost
total_investment_over_lifetime_per(:plant) Investment over lifetime per plant 484 484 EUR / unit
fixed_operation_and_maintenance_costs_per(:plant) Fixed operation and maintenance costs 30 30 EUR / unit / year
variable_operation_and_maintenance_costs_per(:full_load_hour) Variable operation and maintenance costs 0 0 EUR / full load hour
wacc Weighted average cost of capital 2.0 2.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
technical_lifetime Technical lifetime 15 15 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 0 0 MWe
heat_output_capacity 0.024 0.024 0% MWth
hydrogen_output_capacity 0 0 MW
free_co2_factor 0 0
ccs_capture_rate - -
construction_time 0 0
electrical_efficiency_when_using_coal - -
electrical_efficiency_when_using_wood_pellets - -
full_load_hours 71.12 71.12 0%
households_supplied_per_unit 0 0
land_use_per_unit - -
takes_part_in_ets 0 0 yes=1 / no=0
technical_lifetime 15 15 0% year
typical_input_capacity - - MWinput
output_capacity - - MW
input_efficiency - -
output_efficiency - -
cost
initial_investment 484 484 0% euro / unit
ccs_investment 0 0 euro / unit
cost_of_installing 0 0 euro / unit
decommissioning_costs 0 0 euro / unit
fixed_operation_and_maintenance_costs_per_year 30 30 0% euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 0 0 euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 0 0 euro / full load hour
fixed_costs_per_mw_input_capacity - - euro / MWinput
costs_per_mj - -
wacc 0.02 0.02 0%
profitability - - profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity - - eur/MWh
marginal_costs - - euro / MWh
max_consumption_price - - euro / MWh
merit_order
merit_order_full_load_hours - -
merit_order_capacity_factor - -
merit_order_position - -
security_of_supply
availability 0 0
part_load_operating_point - -
part_load_efficiency_penalty - -
forecasting_error - -
misc
demand_expected_value 1.75 B 1.75 B 0%
excel_id - -
max_demand - -
Node Calculations Present Future Change Unit
demand
demand 1.75 B 1.75 B 0%
preset_demand - -
demand_of_sustainable 0 0
weighted_carrier_cost_per_mj 0.005 0.005 0%
weighted_carrier_co2_per_mj 0.056 0.056 0%
sustainability_share 0.003 0.003 0%
final_demand 1.75 B 1.75 B 0%
primary_demand 1.78 B 1.78 B 0%
primary_demand_of_fossil 1.77 B 1.77 B 0%
primary_demand_of_sustainable 6,205 K 6,205 K 0%
primary_demand_of_biogas 6,149 K 6,149 K 0%
primary_demand_of_lng 30.07 M 30.07 M 0%
primary_demand_of_natural_gas 1.74 B 1.74 B 0%
technical
input_capacity 0.036 0.036 0%
electric_based_input_capacity - - MWinput
heat_based_input_capacity 0.036 0.036 0% MWinput
cooling_based_input_capacity - - MWinput
number_of_units 191 K 191 K 0%
costs_per_plant
total_costs_per(:plant) 114 114 0% euro / plant
fixed_costs_per(:plant) 67.11 67.11 0%
cost_of_capital_per(:plant) 4.84 4.84 0%
depreciation_costs_per(:plant) 32.27 32.27 0%
variable_costs_per(:plant) 46.9 46.9 0%
fuel_costs_per(:plant) 46.9 46.9 0%
co2_emissions_costs_per(:plant) 0 0
captured_biogenic_co2_costs_per(:plant) 0 0
fixed_operation_and_maintenance_costs_per(:plant) 30 30 0%
variable_operation_and_maintenance_costs_per(:plant) 0 0
total_initial_investment_per(:plant) 484 484 0%
costs_per_node
total_costs_per(:node) 21.78 M 21.78 M 0%
fixed_costs_per(:node) 12.82 M 12.82 M 0%
cost_of_capital_per(:node) 925 K 925 K 0%
depreciation_costs_per(:node) 6,165 K 6,165 K 0%
variable_costs_per(:node) 8,960 K 8,960 K 0%
fuel_costs_per(:node) 8,960 K 8,960 K 0%
co2_emissions_costs_per(:node) 0 0
captured_biogenic_co2_costs_per(:node) 0 0
fixed_operation_and_maintenance_costs_per(:node) 5,731 K 5,731 K 0%
variable_operation_and_maintenance_costs_per(:node) 0 0
total_initial_investment_per(:node) 92.47 M 92.47 M 0%
costs_per_mw_electricity
total_costs_per(:mw_electricity) 0 0
fixed_costs_per(:mw_electricity) 0 0
cost_of_capital_per(:mw_electricity) 0 0
depreciation_costs_per(:mw_electricity) 0 0
variable_costs_per(:mw_electricity) 0 0
fuel_costs_per(:mw_electricity) 0 0
co2_emissions_costs_per(:mw_electricity) NaN NaN
captured_biogenic_co2_costs_per(:mw_electricity) NaN NaN
fixed_operation_and_maintenance_costs_per(:mw_electricity) 0 0
variable_operation_and_maintenance_costs_per(:mw_electricity) NaN NaN
total_initial_investment_per(:mw_electricity) 0 0
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 0 0
fixed_costs_per(:mwh_electricity) 0 0
cost_of_capital_per(:mwh_electricity) 0 0
depreciation_costs_per(:mwh_electricity) 0 0
variable_costs_per(:mwh_electricity) 0 0
fuel_costs_per(:mwh_electricity) 0 0
co2_emissions_costs_per(:mwh_electricity) NaN NaN
captured_biogenic_co2_costs_per(:mwh_electricity) NaN NaN
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 0 0
variable_operation_and_maintenance_costs_per(:mwh_electricity) NaN NaN
total_initial_investment_per(:mwh_electricity) 0 0
costs_per_mw_heat
total_costs_per(:mw_heat) 4,750.2 4,750.2 0%
fixed_costs_per(:mw_heat) 2,796.1 2,796.1 0%
cost_of_capital_per(:mw_heat) 201.7 201.7 0%
depreciation_costs_per(:mw_heat) 1,344.4 1,344.4 0%
variable_costs_per(:mw_heat) 1,954.1 1,954.1 0%
fuel_costs_per(:mw_heat) 1,954.1 1,954.1 0%
co2_emissions_costs_per(:mw_heat) 0 0
captured_biogenic_co2_costs_per(:mw_heat) 0 0
fixed_operation_and_maintenance_costs_per(:mw_heat) 1,250 1,250 0%
variable_operation_and_maintenance_costs_per(:mw_heat) 0 0
total_initial_investment_per(:mw_heat) 20,166.7 20,166.7 0%
costs_per_mwh_heat
total_costs_per(:mwh_heat) 66.79 66.79 0%
fixed_costs_per(:mwh_heat) 39.31 39.31 0%
cost_of_capital_per(:mwh_heat) 2.84 2.84 0%
depreciation_costs_per(:mwh_heat) 18.9 18.9 0%
variable_costs_per(:mwh_heat) 27.47 27.47 0%
fuel_costs_per(:mwh_heat) 27.47 27.47 0%
co2_emissions_costs_per(:mwh_heat) 0 0
captured_biogenic_co2_costs_per(:mwh_heat) 0 0
fixed_operation_and_maintenance_costs_per(:mwh_heat) 17.57 17.57 0%
variable_operation_and_maintenance_costs_per(:mwh_heat) 0 0
total_initial_investment_per(:mwh_heat) 283.5 283.5 0%