Present 0 0 0
Future 0 0 0
Edges 0 Outputs
Node MJ Type
industry_locally_available_electricity 0 Flexible
Reversed
27.9 %
0.0 %
Node MJ Type
industry_locally_available_steam_hot_water 0 Flexible
Reversed
83.5 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_distribution_wood_pellets
Edges 0 Outputs
Node MJ Type
industry_locally_available_electricity 0 Flexible
Reversed
27.9 %
0.0 %
Node MJ Type
industry_locally_available_steam_hot_water 0 Flexible
Reversed
83.5 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_distribution_wood_pellets

Details

Sector industry
Use energetic
Merit Order
level
mv
subtype
dispatchable
type
producer
Node groups
  1. preset_demand
  2. electricity_production
  3. dispatchable_production
  4. heat_production
  5. mv_net_supply
  6. wacc_proven_tech
  7. costs_production_chp_plants
  8. sankey_conversion_group
Used in Gqueries
  1. chp_electricity_in_source_of_heat_and_electricity_in_industry
  2. chp_heat_in_source_of_heat_and_electricity_in_industry
  3. factsheet_demand_of_biomass_industry
  4. factsheet_demand_of_biomass_other
  5. factsheet_supply_heat_from_rest_and_geothermal
  6. industry_biomass_total_in_co2_sankey
  7. industry_chp_wood_pellets
  8. industry_chp_wood_pellets_capacity_in_chp_properties
  9. industry_chp_wood_pellets_delta_in_investment_cost_table
  10. industry_chp_wood_pellets_electricity_production_in_chp_properties
  11. industry_chp_wood_pellets_future_in_investment_cost_table
  12. industry_chp_wood_pellets_heat_production_in_chp_properties
  13. industry_chp_wood_pellets_in_industrial_heat_network_mekko
  14. industry_chp_wood_pellets_number_of_units_in_chp_properties
  15. industry_chp_wood_pellets_present_in_investment_cost_table
  16. merit_order_industry_chp_wood_availability_in_merit_order_table
  17. merit_order_industry_chp_wood_capacity_in_merit_order_table
  18. merit_order_industry_chp_wood_full_load_hours_in_merit_order_table
  19. merit_order_industry_chp_wood_load_factor_in_merit_order_table
  20. merit_order_industry_chp_wood_operating_costs_in_merit_order_table
  21. merit_order_industry_chp_wood_position_in_merit_order_table
  22. total_cost_of_industry_chp_wood_pellets
Used in Inputs
  1. capacity_of_industry_chp_wood_pellets
  2. efficiency_industry_chp_wood_pellets_electricity
  3. efficiency_industry_chp_wood_pellets_heat
  4. external_coupling_capacity_of_industry_chp_wood_pellets
  5. external_coupling_efficiency_industry_chp_wood_pellets_electricity
  6. external_coupling_efficiency_industry_chp_wood_pellets_heat
  7. investment_costs_combustion_biomass_plants
  8. om_costs_combustion_biomass_plant
Method Label Present Future Unit
technical
electricity_output_capacity * number_of_units Installed electrical capacity 0 0 MW
electricity_output_conversion Electrical efficiency 27.9 27.9 %
heat_output_conversion Heat efficiency 83.5 83.5 %
full_load_hours Full load hours 6,000 0 hour / year
cost
total_investment_over_lifetime_per(:mw_electricity) Investment over lifetime per MW 3500091 3500091 EUR / MW
fixed_operation_and_maintenance_costs_per(:mw_electricity) Fixed operation and maintenance costs 29500 29500 EUR / MW / year
variable_operation_and_maintenance_costs_per_full_load_hour Variable operation and maintenance costs 194 194 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
technical_lifetime Technical lifetime 25 25 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 176.5 176.5 0% MWe
heat_output_capacity 528.2 528.2 0% MWth
hydrogen_output_capacity 0 0 MW
free_co2_factor 0 0
ccs_capture_rate - -
construction_time 1 1 0%
electrical_efficiency_when_using_coal - -
electrical_efficiency_when_using_wood_pellets - -
full_load_hours 6,000 0 -100%
households_supplied_per_unit - -
land_use_per_unit - -
takes_part_in_ets 0 0 yes=1 / no=0
technical_lifetime 25 25 0% year
typical_input_capacity 632.6 632.6 0% MWinput
output_capacity - - MW
input_efficiency - -
output_efficiency - -
cost
initial_investment 617.75 M 617.75 M 0% euro / unit
ccs_investment 0 0 euro / unit
cost_of_installing 0 0 euro / unit
decommissioning_costs 0 0 euro / unit
fixed_operation_and_maintenance_costs_per_year 5,207 K 5,207 K 0% euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 194.2 194.2 0% euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 0 0 euro / full load hour
fixed_costs_per_mw_input_capacity - - euro / MWinput
costs_per_mj - -
wacc 0.04 0.04 0%
profitability - profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity - - eur/MWh
marginal_costs 31.06 31.06 0% euro / MWh
max_consumption_price 31.06 31.06 0% euro / MWh
merit_order
merit_order_full_load_hours - -
merit_order_capacity_factor - -
merit_order_position - -
security_of_supply
availability 0.9 0.9 0%
part_load_operating_point - -
part_load_efficiency_penalty - -
forecasting_error - -
misc
demand_expected_value - -
excel_id - -
max_demand - -
Node Calculations Present Future Change Unit
demand
demand 0 0
preset_demand 0 0
demand_of_sustainable 0 0
weighted_carrier_cost_per_mj 0.008 0.008 0%
weighted_carrier_co2_per_mj 0 0
sustainability_share 1 1 0%
final_demand 0 0
primary_demand 0 0
primary_demand_of_fossil 0 0
primary_demand_of_sustainable 0 0
technical
input_capacity 632.6 632.6 0%
electric_based_input_capacity 632.6 632.6 0% MWinput
heat_based_input_capacity 632.6 632.6 0% MWinput
cooling_based_input_capacity - - MWinput
number_of_units 0 0
costs_per_plant
total_costs_per(:plant) 157.63 M 42.77 M -72% euro / plant
fixed_costs_per(:plant) 42.77 M 42.77 M 0%
cost_of_capital_per(:plant) 12.85 M 12.85 M 0%
depreciation_costs_per(:plant) 24.71 M 24.71 M 0%
variable_costs_per(:plant) 114.87 M 0 -100%
fuel_costs_per(:plant) 113.7 M 0 -100%
co2_emissions_costs_per(:plant) 0 0
captured_biogenic_co2_costs_per(:plant) 0 0
fixed_operation_and_maintenance_costs_per(:plant) 5,207 K 5,207 K 0%
variable_operation_and_maintenance_costs_per(:plant) 1,165 K 0 -100%
total_initial_investment_per(:plant) 617.75 M 617.75 M 0%
costs_per_node
total_costs_per(:node) 0 0
fixed_costs_per(:node) 0 0
cost_of_capital_per(:node) 0 0
depreciation_costs_per(:node) 0 0
variable_costs_per(:node) 0 0
fuel_costs_per(:node) 0 0
co2_emissions_costs_per(:node) 0 0
captured_biogenic_co2_costs_per(:node) 0 0
fixed_operation_and_maintenance_costs_per(:node) 0 0
variable_operation_and_maintenance_costs_per(:node) 0 0
total_initial_investment_per(:node) 0 0
costs_per_mw_electricity
total_costs_per(:mw_electricity) 893 K 242 K -72%
fixed_costs_per(:mw_electricity) 242 K 242 K 0%
cost_of_capital_per(:mw_electricity) 72,801.9 72,801.9 0%
depreciation_costs_per(:mw_electricity) 140 K 140 K 0%
variable_costs_per(:mw_electricity) 651 K 0 -100%
fuel_costs_per(:mw_electricity) 644 K 0 -100%
co2_emissions_costs_per(:mw_electricity) 0 0
captured_biogenic_co2_costs_per(:mw_electricity) 0 0
fixed_operation_and_maintenance_costs_per(:mw_electricity) 29,500.8 29,500.8 0%
variable_operation_and_maintenance_costs_per(:mw_electricity) 6,600.2 0 -100%
total_initial_investment_per(:mw_electricity) 3,500 K 3,500 K 0%
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 148.9 0 -100%
fixed_costs_per(:mwh_electricity) 40.38 0 -100%
cost_of_capital_per(:mwh_electricity) 12.13 0 -100%
depreciation_costs_per(:mwh_electricity) 23.33 0 -100%
variable_costs_per(:mwh_electricity) 108.5 NaN
fuel_costs_per(:mwh_electricity) 107.4 NaN
co2_emissions_costs_per(:mwh_electricity) 0 NaN
captured_biogenic_co2_costs_per(:mwh_electricity) 0 NaN
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 4.92 0 -100%
variable_operation_and_maintenance_costs_per(:mwh_electricity) 1.1 NaN
total_initial_investment_per(:mwh_electricity) 583.3 0 -100%
costs_per_mw_heat
total_costs_per(:mw_heat) 298 K 80,962.2 -72%
fixed_costs_per(:mw_heat) 80,962.2 80,962.2 0%
cost_of_capital_per(:mw_heat) 24,325.4 24,325.4 0%
depreciation_costs_per(:mw_heat) 46,779.7 46,779.7 0%
variable_costs_per(:mw_heat) 217 K 0 -100%
fuel_costs_per(:mw_heat) 215 K 0 -100%
co2_emissions_costs_per(:mw_heat) 0 0
captured_biogenic_co2_costs_per(:mw_heat) 0 0
fixed_operation_and_maintenance_costs_per(:mw_heat) 9,857.1 9,857.1 0%
variable_operation_and_maintenance_costs_per(:mw_heat) 2,205.3 0 -100%
total_initial_investment_per(:mw_heat) 1,169 K 1,169 K 0%
costs_per_mwh_heat
total_costs_per(:mwh_heat) 49.74 0 -100%
fixed_costs_per(:mwh_heat) 13.49 0 -100%
cost_of_capital_per(:mwh_heat) 4.05 0 -100%
depreciation_costs_per(:mwh_heat) 7.8 0 -100%
variable_costs_per(:mwh_heat) 36.24 NaN
fuel_costs_per(:mwh_heat) 35.88 NaN
co2_emissions_costs_per(:mwh_heat) 0 NaN
captured_biogenic_co2_costs_per(:mwh_heat) 0 NaN
fixed_operation_and_maintenance_costs_per(:mwh_heat) 1.64 0 -100%
variable_operation_and_maintenance_costs_per(:mwh_heat) 0.368 NaN
total_initial_investment_per(:mwh_heat) 194.9 0 -100%