Present 0 0 0
Future 0 0 0
Edges 0 Outputs
Node MJ Type
energy_power_hv_network_electricity 0 Flexible
Reversed
20.45 %
59.6 %
Node MJ Type
energy_transmission_ht_steam_hot_water 0 Flexible
Reversed
19.95 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_distribution_waste_mix
Edges 0 Outputs
Node MJ Type
energy_power_hv_network_electricity 0 Flexible
Reversed
20.45 %
59.6 %
Node MJ Type
energy_transmission_ht_steam_hot_water 0 Flexible
Reversed
19.95 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_distribution_waste_mix

Details

Sector energy
Use energetic
Heat network (HT)
group
self: electricity_output_curve
subtype
must_run
type
producer
Merit Order
level
hv
subtype
dispatchable
type
producer
Node groups
  1. preset_demand
  2. central_production
  3. electricity_production
  4. ccs_technology_pair
  5. dispatchable_production
  6. heat_production
  7. hv_net_supply
  8. wacc_proven_tech
  9. primary_heat_infrastructure
  10. costs_production_chp_plants
  11. sankey_conversion_group
Used in Gqueries
  1. costs_of_waste_chp_ccs_in_overview_costs_of_electricity_production
  2. energy_chp_supercritical_ccs_ht_waste_mix_capacity_in_chp_properties
  3. energy_chp_supercritical_ccs_ht_waste_mix_electricity_production_in_chp_properties
  4. energy_chp_supercritical_ccs_ht_waste_mix_heat_production_in_chp_properties
  5. energy_chp_supercritical_ccs_ht_waste_mix_number_of_units_in_chp_properties
  6. energy_chp_supercritical_ccs_waste_mix
  7. energy_chp_supercritical_ccs_waste_mix_ht_steam_hot_water_output_curve
  8. factsheet_supply_heat_from_rest_and_geothermal
  9. investment_for_waste_chp_ccs_in_overview_costs_of_electricity_production
  10. merit_order_waste_chp_ccs_ht_availability_in_merit_order_table
  11. merit_order_waste_chp_ccs_ht_capacity_in_merit_order_table
  12. merit_order_waste_chp_ccs_ht_full_load_hours_in_merit_order_table
  13. merit_order_waste_chp_ccs_ht_load_factor_in_merit_order_table
  14. merit_order_waste_chp_ccs_ht_operating_costs_in_merit_order_table
  15. merit_order_waste_chp_ccs_ht_position_in_merit_order_table
Used in Inputs
  1. capacity_of_energy_chp_supercritical_waste_mix
  2. external_coupling_energy_chp_supercritical_ccs_waste_mix_captured_co2
  3. external_coupling_energy_chp_supercritical_ccs_waste_mix_electrical_efficiency
  4. external_coupling_energy_chp_supercritical_ccs_waste_mix_heat_efficiency
  5. external_coupling_energy_chp_supercritical_waste_mix_capacity
  6. investment_costs_co2_ccs
  7. investment_costs_combustion_waste_incinerator
  8. om_costs_co2_ccs
  9. om_costs_combustion_waste_incinerator
  10. share_of_energy_chp_supercritical_ccs_ht_waste_mix
  11. share_of_energy_chp_supercritical_ht_waste_mix
  12. share_of_energy_chp_supercritical_mt_waste_mix
Method Label Present Future Unit
technical
electricity_output_capacity * number_of_units Installed electrical capacity 0 0 MW
electricity_output_conversion Electrical efficiency 20.4 20.4 %
full_load_hours Full load hours 4,390 0 hour / year
cost
initial_investment_per(:mw_electricity) + cost_of_installing_per(:mw_electricity) + decommissioning_costs_per(:mw_electricity) Investment over lifetime per MW 2796244 2796244 EUR / MW
ccs_investment_per(:mw_electricity) Additional initial investment for CCS 1190992 1190992 EUR / MW
fixed_operation_and_maintenance_costs_per(:mw_electricity) Fixed operation and maintenance costs 82851 82851 EUR / MW / year
variable_operation_and_maintenance_costs_per_full_load_hour Variable operation and maintenance costs (excl CCS) 0 0 EUR / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour Additional variable operation and maintenance costs for CCS 0 0 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? true true boolean
other
technical_lifetime Technical lifetime 30 30 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 57.93 57.93 0% MWe
heat_output_capacity 56.52 56.52 0% MWth
hydrogen_output_capacity 0 0 MW
free_co2_factor 0.85 0.85 0%
ccs_capture_rate 0.85 0.85 0%
construction_time 3.5 3.5 0%
electrical_efficiency_when_using_coal - -
electrical_efficiency_when_using_wood_pellets - -
full_load_hours 4,390 0 -100%
households_supplied_per_unit - -
land_use_per_unit - -
takes_part_in_ets 1 1 0% yes=1 / no=0
technical_lifetime 30 30 0% year
typical_input_capacity 283.3 283.3 0% MWinput
output_capacity - - MW
input_efficiency - -
output_efficiency - -
cost
initial_investment 162 M 162 M 0% euro / unit
ccs_investment 69 M 69 M 0% euro / unit
cost_of_installing 0 0 euro / unit
decommissioning_costs 0 0 euro / unit
fixed_operation_and_maintenance_costs_per_year 4,800 K 4,800 K 0% euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 0 0 euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 0 0 euro / full load hour
fixed_costs_per_mw_input_capacity - - euro / MWinput
costs_per_mj - -
wacc 0.04 0.04 0%
profitability - profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity - - eur/MWh
marginal_costs 0 0 euro / MWh
max_consumption_price 0 0 euro / MWh
merit_order
merit_order_full_load_hours - -
merit_order_capacity_factor - -
merit_order_position - -
security_of_supply
availability 0.9 0.9 0%
part_load_operating_point - -
part_load_efficiency_penalty - -
forecasting_error - -
misc
demand_expected_value - -
excel_id - -
max_demand - -
Node Calculations Present Future Change Unit
demand
demand 0 0
preset_demand 0 0
demand_of_sustainable 0 0
weighted_carrier_cost_per_mj 0 0
weighted_carrier_co2_per_mj 0.049 0.049 0%
sustainability_share 0.53 0.53 0%
final_demand 0 0
primary_demand 0 0
primary_demand_of_fossil 0 0
primary_demand_of_sustainable 0 0
technical
input_capacity 283.3 283.3 0%
electric_based_input_capacity 283.3 283.3 0% MWinput
heat_based_input_capacity 283.3 283.3 0% MWinput
cooling_based_input_capacity - - MWinput
number_of_units 0 0
costs_per_plant
total_costs_per(:plant) 13.15 M 17.66 M 34% euro / plant
fixed_costs_per(:plant) 17.66 M 17.66 M 0%
cost_of_capital_per(:plant) 5,159 K 5,159 K 0%
depreciation_costs_per(:plant) 7,700 K 7,700 K 0%
variable_costs_per(:plant) -4,514 K 0 -100%
fuel_costs_per(:plant) 0 0
co2_emissions_costs_per(:plant) 495 K 0 -100%
captured_biogenic_co2_costs_per(:plant) -5,008 K 0 -100%
fixed_operation_and_maintenance_costs_per(:plant) 4,800 K 4,800 K 0%
variable_operation_and_maintenance_costs_per(:plant) 0 0
total_initial_investment_per(:plant) 231 M 231 M 0%
costs_per_node
total_costs_per(:node) 0 0
fixed_costs_per(:node) 0 0
cost_of_capital_per(:node) 0 0
depreciation_costs_per(:node) 0 0
variable_costs_per(:node) 0 0
fuel_costs_per(:node) 0 0
co2_emissions_costs_per(:node) 0 0
captured_biogenic_co2_costs_per(:node) 0 0
fixed_operation_and_maintenance_costs_per(:node) 0 0
variable_operation_and_maintenance_costs_per(:node) 0 0
total_initial_investment_per(:node) 0 0
costs_per_mw_electricity
total_costs_per(:mw_electricity) 227 K 305 K 34%
fixed_costs_per(:mw_electricity) 305 K 305 K 0%
cost_of_capital_per(:mw_electricity) 89,048.3 89,048.3 0%
depreciation_costs_per(:mw_electricity) 133 K 133 K 0%
variable_costs_per(:mw_electricity) -77,907.3 0 -100%
fuel_costs_per(:mw_electricity) 0 0
co2_emissions_costs_per(:mw_electricity) 8,539 0 -100%
captured_biogenic_co2_costs_per(:mw_electricity) -86,446.2 0 -100%
fixed_operation_and_maintenance_costs_per(:mw_electricity) 82,851.7 82,851.7 0%
variable_operation_and_maintenance_costs_per(:mw_electricity) 0 0
total_initial_investment_per(:mw_electricity) 3,987 K 3,987 K 0%
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 51.69 0 -100%
fixed_costs_per(:mwh_electricity) 69.43 0 -100%
cost_of_capital_per(:mwh_electricity) 20.28 0 -100%
depreciation_costs_per(:mwh_electricity) 30.28 0 -100%
variable_costs_per(:mwh_electricity) -17.75 NaN
fuel_costs_per(:mwh_electricity) 0 NaN
co2_emissions_costs_per(:mwh_electricity) 1.95 NaN
captured_biogenic_co2_costs_per(:mwh_electricity) -19.69 NaN
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 18.87 0 -100%
variable_operation_and_maintenance_costs_per(:mwh_electricity) 0 NaN
total_initial_investment_per(:mwh_electricity) 908.3 0 -100%
costs_per_mw_heat
total_costs_per(:mw_heat) 233 K 312 K 34%
fixed_costs_per(:mw_heat) 312 K 312 K 0%
cost_of_capital_per(:mw_heat) 91,280.1 91,280.1 0%
depreciation_costs_per(:mw_heat) 136 K 136 K 0%
variable_costs_per(:mw_heat) -79,859.8 0 -100%
fuel_costs_per(:mw_heat) 0 0
co2_emissions_costs_per(:mw_heat) 8,753 0 -100%
captured_biogenic_co2_costs_per(:mw_heat) -88,612.8 0 -100%
fixed_operation_and_maintenance_costs_per(:mw_heat) 84,928.2 84,928.2 0%
variable_operation_and_maintenance_costs_per(:mw_heat) 0 0
total_initial_investment_per(:mw_heat) 4,087 K 4,087 K 0%
costs_per_mwh_heat
total_costs_per(:mwh_heat) 52.98 0 -100%
fixed_costs_per(:mwh_heat) 71.17 0 -100%
cost_of_capital_per(:mwh_heat) 20.79 0 -100%
depreciation_costs_per(:mwh_heat) 31.03 0 -100%
variable_costs_per(:mwh_heat) -18.19 NaN
fuel_costs_per(:mwh_heat) 0 NaN
co2_emissions_costs_per(:mwh_heat) 1.99 NaN
captured_biogenic_co2_costs_per(:mwh_heat) -20.19 NaN
fixed_operation_and_maintenance_costs_per(:mwh_heat) 19.35 0 -100%
variable_operation_and_maintenance_costs_per(:mwh_heat) 0 NaN
total_initial_investment_per(:mwh_heat) 931 0 -100%