Present 7.96 B 7.96 B 7.96 B
Future 7.96 B 7.96 B 7.96 B
Edges 7.96 B Outputs
Node MJ Type
energy_power_mv_distribution_network_electricity 3.42 B Flexible
Reversed
43.0 %
10.0 %
Node MJ Type
energy_production_aggregator_ht_steam_hot_water 3.74 B Flexible
Reversed
47.0 %
Inputs Edges 7.96 B
100.0 %
Type MJ Node
Share 7.96 B energy_distribution_biogas
Edges 7.96 B Outputs
Node MJ Type
energy_power_mv_distribution_network_electricity 3.42 B Flexible
Reversed
43.0 %
10.0 %
Node MJ Type
energy_production_aggregator_ht_steam_hot_water 3.74 B Flexible
Reversed
47.0 %
Inputs Edges 7.96 B
100.0 %
Type MJ Node
Share 7.96 B energy_distribution_biogas

Details

Sector energy
Use energetic
Heat network (HT)
group
flat
subtype
must_run
type
producer
Merit Order
group
flat
level
mv
subtype
must_run
type
producer
Node groups
  1. preset_demand
  2. electricity_production
  3. heat_production
  4. must_run_electricity_production
  5. wacc_proven_tech
  6. costs_production_chp_plants
  7. sankey_conversion_group
Used in Gqueries
  1. costs_of_central_biogas_chp_in_overview_costs_of_electricity_production
  2. energy_biomass_total_in_co2_sankey
  3. energy_chp_local_engine_biogas
  4. energy_chp_local_engine_biogas_ht_steam_hot_water_output_curve
  5. energy_chp_local_engine_ht_biogas_capacity_in_chp_properties
  6. energy_chp_local_engine_ht_biogas_electricity_production_in_chp_properties
  7. energy_chp_local_engine_ht_biogas_heat_production_in_chp_properties
  8. energy_chp_local_engine_ht_biogas_number_of_units_in_chp_properties
  9. factsheet_supply_heat_from_rest_and_geothermal
  10. investment_for_central_biogas_chp_in_overview_costs_of_electricity_production
  11. merit_order_biogas_chp_ht_availability_in_merit_order_table
  12. merit_order_biogas_chp_ht_capacity_in_merit_order_table
  13. merit_order_biogas_chp_ht_full_load_hours_in_merit_order_table
  14. merit_order_biogas_chp_ht_load_factor_in_merit_order_table
  15. merit_order_biogas_chp_ht_operating_costs_in_merit_order_table
  16. merit_order_biogas_chp_ht_position_in_merit_order_table
Used in Inputs
  1. capacity_of_energy_chp_local_engine_biogas
  2. efficiency_energy_chp_local_engine_biogas_electricity
  3. efficiency_energy_chp_local_engine_biogas_heat
  4. investment_costs_combustion_biomass_plants
  5. om_costs_combustion_biomass_plant
  6. share_of_energy_chp_local_engine_ht_biogas
  7. share_of_energy_chp_local_engine_mt_biogas
Method Label Present Future Unit
technical
electricity_output_capacity * number_of_units Installed electrical capacity 118.9 118.9 MW
electricity_output_conversion Electrical efficiency 43.0 43.0 %
heat_output_conversion Heat efficiency 47.0 47.0 %
full_load_hours Full load hours 8,000 8,000 hour / year
cost
total_investment_over_lifetime_per(:mw_electricity) Investment over lifetime per MW 593765 593765 EUR / MW
fixed_operation_and_maintenance_costs_per(:mw_electricity) Fixed operation and maintenance costs 0 0 EUR / MW / year
variable_operation_and_maintenance_costs_per_full_load_hour Variable operation and maintenance costs 16 16 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
technical_lifetime Technical lifetime 20 20 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 2.02 2.02 0% MWe
heat_output_capacity 2.21 2.21 0% MWth
hydrogen_output_capacity 0 0 MW
free_co2_factor 0 0
ccs_capture_rate - -
construction_time 1.1 1.1 0%
electrical_efficiency_when_using_coal - -
electrical_efficiency_when_using_wood_pellets - -
full_load_hours 8,000 8,000 0%
households_supplied_per_unit - -
land_use_per_unit - -
takes_part_in_ets 0 0 yes=1 / no=0
technical_lifetime 20 20 0% year
typical_input_capacity 4.7 4.7 0% MWinput
output_capacity - - MW
input_efficiency - -
output_efficiency - -
cost
initial_investment 1,200 K 1,200 K 0% euro / unit
ccs_investment 0 0 euro / unit
cost_of_installing 0 0 euro / unit
decommissioning_costs 0 0 euro / unit
fixed_operation_and_maintenance_costs_per_year 0 0 euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 16 16 0% euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 0 0 euro / full load hour
fixed_costs_per_mw_input_capacity - - euro / MWinput
costs_per_mj - -
wacc 0.04 0.04 0%
profitability - - profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity - - eur/MWh
marginal_costs 140.5 140.5 0% euro / MWh
max_consumption_price 140.5 140.5 0% euro / MWh
merit_order
merit_order_full_load_hours - -
merit_order_capacity_factor - -
merit_order_position - -
security_of_supply
availability 0.95 0.95 0%
part_load_operating_point - -
part_load_efficiency_penalty - -
forecasting_error - -
misc
demand_expected_value - -
excel_id - -
max_demand - -
Node Calculations Present Future Change Unit
demand
demand 7.96 B 7.96 B 0%
preset_demand 7.96 B 7.96 B 0%
demand_of_sustainable 0 0
weighted_carrier_cost_per_mj 0.016 0.016 0%
weighted_carrier_co2_per_mj 0 0
sustainability_share 1 1 0%
final_demand 0 0
primary_demand 7.96 B 7.96 B 0%
primary_demand_of_fossil 0 0
primary_demand_of_sustainable 7.96 B 7.96 B 0%
primary_demand_of_biogas 7.96 B 7.96 B 0%
technical
input_capacity 4.7 4.7 0%
electric_based_input_capacity 4.7 4.7 0% MWinput
heat_based_input_capacity 4.7 4.7 0% MWinput
cooling_based_input_capacity - - MWinput
number_of_units 58.82 58.82 0%
costs_per_plant
total_costs_per(:plant) 2,357 K 2,357 K 0% euro / plant
fixed_costs_per(:plant) 85,320 85,320 0%
cost_of_capital_per(:plant) 25,320 25,320 0%
depreciation_costs_per(:plant) 60,000 60,000 0%
variable_costs_per(:plant) 2,271 K 2,271 K 0%
fuel_costs_per(:plant) 2,143 K 2,143 K 0%
co2_emissions_costs_per(:plant) 0 0
captured_biogenic_co2_costs_per(:plant) 0 0
fixed_operation_and_maintenance_costs_per(:plant) 0 0
variable_operation_and_maintenance_costs_per(:plant) 128 K 128 K 0%
total_initial_investment_per(:plant) 1,200 K 1,200 K 0%
costs_per_node
total_costs_per(:node) 138.62 M 138.62 M 0%
fixed_costs_per(:node) 5,019 K 5,019 K 0%
cost_of_capital_per(:node) 1,489 K 1,489 K 0%
depreciation_costs_per(:node) 3,529 K 3,529 K 0%
variable_costs_per(:node) 133.6 M 133.6 M 0%
fuel_costs_per(:node) 126.07 M 126.07 M 0%
co2_emissions_costs_per(:node) 0 0
captured_biogenic_co2_costs_per(:node) 0 0
fixed_operation_and_maintenance_costs_per(:node) 0 0
variable_operation_and_maintenance_costs_per(:node) 7,530 K 7,530 K 0%
total_initial_investment_per(:node) 70.59 M 70.59 M 0%
costs_per_mw_electricity
total_costs_per(:mw_electricity) 1,166 K 1,166 K 0%
fixed_costs_per(:mw_electricity) 42,216.7 42,216.7 0%
cost_of_capital_per(:mw_electricity) 12,528.5 12,528.5 0%
depreciation_costs_per(:mw_electricity) 29,688.3 29,688.3 0%
variable_costs_per(:mw_electricity) 1,124 K 1,124 K 0%
fuel_costs_per(:mw_electricity) 1,060 K 1,060 K 0%
co2_emissions_costs_per(:mw_electricity) 0 0
captured_biogenic_co2_costs_per(:mw_electricity) 0 0
fixed_operation_and_maintenance_costs_per(:mw_electricity) 0 0
variable_operation_and_maintenance_costs_per(:mw_electricity) 63,335 63,335 0%
total_initial_investment_per(:mw_electricity) 594 K 594 K 0%
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 145.8 145.8 0%
fixed_costs_per(:mwh_electricity) 5.28 5.28 0%
cost_of_capital_per(:mwh_electricity) 1.57 1.57 0%
depreciation_costs_per(:mwh_electricity) 3.71 3.71 0%
variable_costs_per(:mwh_electricity) 140.5 140.5 0%
fuel_costs_per(:mwh_electricity) 132.6 132.6 0%
co2_emissions_costs_per(:mwh_electricity) 0 0
captured_biogenic_co2_costs_per(:mwh_electricity) 0 0
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 0 0
variable_operation_and_maintenance_costs_per(:mwh_electricity) 7.92 7.92 0%
total_initial_investment_per(:mwh_electricity) 74.22 74.22 0%
costs_per_mw_heat
total_costs_per(:mw_heat) 1,067 K 1,067 K 0%
fixed_costs_per(:mw_heat) 38,623.8 38,623.8 0%
cost_of_capital_per(:mw_heat) 11,462.2 11,462.2 0%
depreciation_costs_per(:mw_heat) 27,161.6 27,161.6 0%
variable_costs_per(:mw_heat) 1,028 K 1,028 K 0%
fuel_costs_per(:mw_heat) 970 K 970 K 0%
co2_emissions_costs_per(:mw_heat) 0 0
captured_biogenic_co2_costs_per(:mw_heat) 0 0
fixed_operation_and_maintenance_costs_per(:mw_heat) 0 0
variable_operation_and_maintenance_costs_per(:mw_heat) 57,944.8 57,944.8 0%
total_initial_investment_per(:mw_heat) 543 K 543 K 0%
costs_per_mwh_heat
total_costs_per(:mwh_heat) 133.3 133.3 0%
fixed_costs_per(:mwh_heat) 4.83 4.83 0%
cost_of_capital_per(:mwh_heat) 1.43 1.43 0%
depreciation_costs_per(:mwh_heat) 3.4 3.4 0%
variable_costs_per(:mwh_heat) 128.5 128.5 0%
fuel_costs_per(:mwh_heat) 121.3 121.3 0%
co2_emissions_costs_per(:mwh_heat) 0 0
captured_biogenic_co2_costs_per(:mwh_heat) 0 0
fixed_operation_and_maintenance_costs_per(:mwh_heat) 0 0
variable_operation_and_maintenance_costs_per(:mwh_heat) 7.24 7.24 0%
total_initial_investment_per(:mwh_heat) 67.9 67.9 0%