Present 0 0 0
Future 0 0 0
Edges 0 Outputs
0.5 %
Node MJ Type
energy_production_aggregator_mt_steam_hot_water 0 Flexible
Reversed
99.5 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_power_mv_distribution_network_electricity
Edges 0 Outputs
0.5 %
Node MJ Type
energy_production_aggregator_mt_steam_hot_water 0 Flexible
Reversed
99.5 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_power_mv_distribution_network_electricity

Details

Sector energy
Use energetic
Heat network (MT)
subtype
dispatchable
type
producer
Merit Order
group
self: steam_hot_water_output_curve
level
mv
subtype
pseudo
type
consumer
Node groups
  1. heat_production
  2. central_production
  3. non_final_electricity_demand_converters
  4. wacc_proven_tech
  5. preset_demand
  6. costs_production_heat_plants
  7. sankey_conversion_group
Used in Gqueries
  1. energy_heat_boiler_electricity_mt_steam_hot_water_output_curve
  2. factsheet_share_of_other_in_collective_heat_sources
  3. heat_cost_capacity_chart_energy_heat_boiler_mt_electricity_availability
  4. heat_cost_capacity_chart_energy_heat_boiler_mt_electricity_capacity
  5. heat_cost_capacity_chart_energy_heat_boiler_mt_electricity_full_load_hours
  6. heat_cost_capacity_chart_energy_heat_boiler_mt_electricity_load_factor
  7. heat_cost_capacity_chart_energy_heat_boiler_mt_electricity_operating_costs
  8. user_sortable_energy_heat_boiler_mt_electricity_capacity
Used in Inputs
  1. capacity_of_energy_heat_boiler_mt_electricity
Method Label Present Future Unit
technical
heat_output_conversion Heat efficiency (LHV) 99.5 99.5 %
heat_output_capacity Heat capacity per unit 50.0 50.0 MW / unit
full_load_hours Full load hours 2,190 0 hour / year
cost
total_investment_over_lifetime_per(:plant) Investment over lifetime per plant 3,000 K 3,000 K EUR / unit
fixed_operation_and_maintenance_costs_per(:plant) Fixed operation and maintenance costs 50,000 50,000 EUR / unit / year
variable_operation_and_maintenance_costs_per(:full_load_hour) Variable operation and maintenance costs 25 NaN EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? false false boolean
other
technical_lifetime Technical lifetime 15 15 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 0 0 MWe
heat_output_capacity 50 50 0% MWth
hydrogen_output_capacity 0 0 MW
free_co2_factor 0 0
ccs_capture_rate - -
construction_time 0 0
electrical_efficiency_when_using_coal - -
electrical_efficiency_when_using_wood_pellets - -
full_load_hours 2,190 0 -100%
households_supplied_per_unit - -
land_use_per_unit - -
takes_part_in_ets 0 0 yes=1 / no=0
technical_lifetime 15 15 0% year
typical_input_capacity - - MWinput
output_capacity - - MW
input_efficiency - -
output_efficiency - -
cost
initial_investment 3,000 K 3,000 K 0% euro / unit
ccs_investment 0 0 euro / unit
cost_of_installing 0 0 euro / unit
decommissioning_costs 0 0 euro / unit
fixed_operation_and_maintenance_costs_per_year 50,000 50,000 0% euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 25 25 0% euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 0 0 euro / full load hour
fixed_costs_per_mw_input_capacity - - euro / MWinput
costs_per_mj - -
wacc 0.04 0.04 0%
profitability - - profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity - - eur/MWh
marginal_costs - - euro / MWh
max_consumption_price - - euro / MWh
merit_order
merit_order_full_load_hours - -
merit_order_capacity_factor - -
merit_order_position - -
security_of_supply
availability 0.99 0.99 0%
part_load_operating_point - -
part_load_efficiency_penalty - -
forecasting_error - -
misc
demand_expected_value - -
excel_id - -
max_demand - -
Node Calculations Present Future Change Unit
demand
demand 0 0
preset_demand 0 0
demand_of_sustainable 0 0
weighted_carrier_cost_per_mj 0.004 0.004 -3%
weighted_carrier_co2_per_mj 0 0
sustainability_share 0.131 0.102 -22%
final_demand 0 0
primary_demand 0 0
primary_demand_of_fossil 0 0
primary_demand_of_sustainable 0 0
technical
input_capacity 50.25 50.25 0%
electric_based_input_capacity - - MWinput
heat_based_input_capacity 50.25 50.25 0% MWinput
cooling_based_input_capacity - - MWinput
number_of_units 0 0
costs_per_plant
total_costs_per(:plant) 1,908 K 310 K -83% euro / plant
fixed_costs_per(:plant) 310 K 310 K 0%
cost_of_capital_per(:plant) 60,000 60,000 0%
depreciation_costs_per(:plant) 200 K 200 K 0%
variable_costs_per(:plant) 1,598 K 0 -100%
fuel_costs_per(:plant) 1,543 K 0 -100%
co2_emissions_costs_per(:plant) 0 0
captured_biogenic_co2_costs_per(:plant) 0 0
fixed_operation_and_maintenance_costs_per(:plant) 50,000 50,000 0%
variable_operation_and_maintenance_costs_per(:plant) 54,750 0 -100%
total_initial_investment_per(:plant) 3,000 K 3,000 K 0%
costs_per_node
total_costs_per(:node) 0 0
fixed_costs_per(:node) 0 0
cost_of_capital_per(:node) 0 0
depreciation_costs_per(:node) 0 0
variable_costs_per(:node) 0 0
fuel_costs_per(:node) 0 0
co2_emissions_costs_per(:node) 0 0
captured_biogenic_co2_costs_per(:node) 0 0
fixed_operation_and_maintenance_costs_per(:node) 0 0
variable_operation_and_maintenance_costs_per(:node) 0 0
total_initial_investment_per(:node) 0 0
costs_per_mw_electricity
total_costs_per(:mw_electricity) 0 0
fixed_costs_per(:mw_electricity) 0 0
cost_of_capital_per(:mw_electricity) 0 0
depreciation_costs_per(:mw_electricity) 0 0
variable_costs_per(:mw_electricity) 0 NaN
fuel_costs_per(:mw_electricity) 0 NaN
co2_emissions_costs_per(:mw_electricity) NaN NaN
captured_biogenic_co2_costs_per(:mw_electricity) NaN NaN
fixed_operation_and_maintenance_costs_per(:mw_electricity) 0 0
variable_operation_and_maintenance_costs_per(:mw_electricity) 0 NaN
total_initial_investment_per(:mw_electricity) 0 0
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 0 0
fixed_costs_per(:mwh_electricity) 0 0
cost_of_capital_per(:mwh_electricity) 0 0
depreciation_costs_per(:mwh_electricity) 0 0
variable_costs_per(:mwh_electricity) 0 NaN
fuel_costs_per(:mwh_electricity) 0 NaN
co2_emissions_costs_per(:mwh_electricity) NaN NaN
captured_biogenic_co2_costs_per(:mwh_electricity) NaN NaN
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 0 0
variable_operation_and_maintenance_costs_per(:mwh_electricity) 0 NaN
total_initial_investment_per(:mwh_electricity) 0 0
costs_per_mw_heat
total_costs_per(:mw_heat) 38,157.7 6,200 -83%
fixed_costs_per(:mw_heat) 6,200 6,200 0%
cost_of_capital_per(:mw_heat) 1,200 1,200 0%
depreciation_costs_per(:mw_heat) 4,000 4,000 0%
variable_costs_per(:mw_heat) 31,957.7 0 -100%
fuel_costs_per(:mw_heat) 30,862.7 0 -100%
co2_emissions_costs_per(:mw_heat) 0 0
captured_biogenic_co2_costs_per(:mw_heat) 0 0
fixed_operation_and_maintenance_costs_per(:mw_heat) 1,000 1,000 0%
variable_operation_and_maintenance_costs_per(:mw_heat) 1,095 0 -100%
total_initial_investment_per(:mw_heat) 60,000 60,000 0%
costs_per_mwh_heat
total_costs_per(:mwh_heat) 17.42 0 -100%
fixed_costs_per(:mwh_heat) 2.83 0 -100%
cost_of_capital_per(:mwh_heat) 0.548 0 -100%
depreciation_costs_per(:mwh_heat) 1.83 0 -100%
variable_costs_per(:mwh_heat) 14.59 NaN
fuel_costs_per(:mwh_heat) 14.09 NaN
co2_emissions_costs_per(:mwh_heat) 0 NaN
captured_biogenic_co2_costs_per(:mwh_heat) 0 NaN
fixed_operation_and_maintenance_costs_per(:mwh_heat) 0.457 0 -100%
variable_operation_and_maintenance_costs_per(:mwh_heat) 0.5 NaN
total_initial_investment_per(:mwh_heat) 27.4 0 -100%