Present 0 0 0
Future 0 0 0
Edges 0 Outputs
Node MJ Type
energy_power_hv_network_electricity 0 Flexible
Reversed
48.0 %
52.0 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_national_gas_network_natural_gas
Edges 0 Outputs
Node MJ Type
energy_power_hv_network_electricity 0 Flexible
Reversed
48.0 %
52.0 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_national_gas_network_natural_gas

Details

Sector energy
Use energetic
Merit Order
level
hv
subtype
dispatchable
type
producer
Network Gas
profile
self: electricity_output_curve
type
consumer
Node groups
  1. preset_demand
  2. central_production
  3. electricity_production
  4. dispatchable_production
  5. hv_net_supply
  6. wacc_proven_tech
  7. costs_production_power_plants
  8. sankey_conversion_group
Used in Gqueries
  1. energy_power_engine_network_gas
  2. merit_order_gas_engine_availability_in_merit_order_table
  3. merit_order_gas_engine_capacity_in_merit_order_table
  4. merit_order_gas_engine_full_load_hours_in_merit_order_table
  5. merit_order_gas_engine_load_factor_in_merit_order_table
  6. merit_order_gas_engine_operating_costs_in_merit_order_table
  7. merit_order_gas_engine_position_in_merit_order_table
  8. total_cost_of_energy_power_engine_network_gas
Used in Inputs
  1. capacity_of_energy_power_engine_network_gas
  2. efficiency_energy_power_engine_network_gas
  3. investment_costs_combustion_gas_plant
  4. om_costs_combustion_gas_plant
Method Label Present Future Unit
technical
electricity_output_capacity * number_of_units Installed electrical capacity 0 0 MW
electricity_output_conversion Electrical efficiency 48.0 48.0 %
full_load_hours Full load hours 1 0 hour / year
cost
total_investment_over_lifetime_per(:mw_electricity) Investment over lifetime per MW 650000 650000 EUR / MW
fixed_operation_and_maintenance_costs_per(:mw_electricity) Fixed operation and maintenance costs 6000 6000 EUR / MW / year
variable_operation_and_maintenance_costs_per_full_load_hour Variable operation and maintenance costs 800 800 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? true true boolean
other
technical_lifetime Technical lifetime 25 25 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 400 400 0% MWe
heat_output_capacity 0 0 MWth
hydrogen_output_capacity 0 0 MW
free_co2_factor 0 0
ccs_capture_rate - -
construction_time 1 1 0%
electrical_efficiency_when_using_coal - -
electrical_efficiency_when_using_wood_pellets - -
full_load_hours 1 0 -100%
households_supplied_per_unit - -
land_use_per_unit 0.1 0.1 0%
takes_part_in_ets 1 1 0% yes=1 / no=0
technical_lifetime 25 25 0% year
typical_input_capacity - - MWinput
output_capacity - - MW
input_efficiency - -
output_efficiency - -
cost
initial_investment 260 M 260 M 0% euro / unit
ccs_investment 0 0 euro / unit
cost_of_installing 0 0 euro / unit
decommissioning_costs 0 0 euro / unit
fixed_operation_and_maintenance_costs_per_year 2,400 K 2,400 K 0% euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 800 800 0% euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 0 0 euro / full load hour
fixed_costs_per_mw_input_capacity - - euro / MWinput
costs_per_mj - -
wacc 0.04 0.04 0%
profitability - profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity - - eur/MWh
marginal_costs 40.84 40.84 0% euro / MWh
max_consumption_price 40.84 40.84 0% euro / MWh
merit_order
merit_order_full_load_hours - -
merit_order_capacity_factor - -
merit_order_position - -
security_of_supply
availability 0.95 0.95 0%
part_load_operating_point 0.014 0.014 0%
part_load_efficiency_penalty 0 0
forecasting_error 0 0
misc
demand_expected_value - -
excel_id - -
max_demand - -
Node Calculations Present Future Change Unit
demand
demand 0 0
preset_demand 0 0
demand_of_sustainable 0 0
weighted_carrier_cost_per_mj 0.005 0.005 0%
weighted_carrier_co2_per_mj 0.056 0.056 0%
sustainability_share 0.003 0.003 0%
final_demand 0 0
primary_demand 0 0
primary_demand_of_fossil 0 0
primary_demand_of_sustainable 0 0
technical
input_capacity 833.3 833.3 0%
electric_based_input_capacity 833.3 833.3 0% MWinput
heat_based_input_capacity - - MWinput
cooling_based_input_capacity - - MWinput
number_of_units 0 0
costs_per_plant
total_costs_per(:plant) 18.22 M 18.21 M 0% euro / plant
fixed_costs_per(:plant) 18.21 M 18.21 M 0%
cost_of_capital_per(:plant) 5,408 K 5,408 K 0%
depreciation_costs_per(:plant) 10.4 M 10.4 M 0%
variable_costs_per(:plant) 16,337.7 0 -100%
fuel_costs_per(:plant) 15,340.1 0 -100%
co2_emissions_costs_per(:plant) 197.6 0 -100%
captured_biogenic_co2_costs_per(:plant) 0 0
fixed_operation_and_maintenance_costs_per(:plant) 2,400 K 2,400 K 0%
variable_operation_and_maintenance_costs_per(:plant) 800 0 -100%
total_initial_investment_per(:plant) 260 M 260 M 0%
costs_per_node
total_costs_per(:node) 0 0
fixed_costs_per(:node) 0 0
cost_of_capital_per(:node) 0 0
depreciation_costs_per(:node) 0 0
variable_costs_per(:node) 0 0
fuel_costs_per(:node) 0 0
co2_emissions_costs_per(:node) 0 0
captured_biogenic_co2_costs_per(:node) 0 0
fixed_operation_and_maintenance_costs_per(:node) 0 0
variable_operation_and_maintenance_costs_per(:node) 0 0
total_initial_investment_per(:node) 0 0
costs_per_mw_electricity
total_costs_per(:mw_electricity) 45,560.8 45,520 0%
fixed_costs_per(:mw_electricity) 45,520 45,520 0%
cost_of_capital_per(:mw_electricity) 13,520 13,520 0%
depreciation_costs_per(:mw_electricity) 26,000 26,000 0%
variable_costs_per(:mw_electricity) 40.84 0 -100%
fuel_costs_per(:mw_electricity) 38.35 0 -100%
co2_emissions_costs_per(:mw_electricity) 0.494 0 -100%
captured_biogenic_co2_costs_per(:mw_electricity) 0 0
fixed_operation_and_maintenance_costs_per(:mw_electricity) 6,000 6,000 0%
variable_operation_and_maintenance_costs_per(:mw_electricity) 2 0 -100%
total_initial_investment_per(:mw_electricity) 650 K 650 K 0%
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 45,560.8 0 -100%
fixed_costs_per(:mwh_electricity) 45,520 0 -100%
cost_of_capital_per(:mwh_electricity) 13,520 0 -100%
depreciation_costs_per(:mwh_electricity) 26,000 0 -100%
variable_costs_per(:mwh_electricity) 40.84 NaN
fuel_costs_per(:mwh_electricity) 38.35 NaN
co2_emissions_costs_per(:mwh_electricity) 0.494 NaN
captured_biogenic_co2_costs_per(:mwh_electricity) 0 NaN
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 6,000 0 -100%
variable_operation_and_maintenance_costs_per(:mwh_electricity) 2 NaN
total_initial_investment_per(:mwh_electricity) 650 K 0 -100%
costs_per_mw_heat
total_costs_per(:mw_heat) 0 0
fixed_costs_per(:mw_heat) 0 0
cost_of_capital_per(:mw_heat) 0 0
depreciation_costs_per(:mw_heat) 0 0
variable_costs_per(:mw_heat) 0 NaN
fuel_costs_per(:mw_heat) 0 NaN
co2_emissions_costs_per(:mw_heat) 0 NaN
captured_biogenic_co2_costs_per(:mw_heat) NaN NaN
fixed_operation_and_maintenance_costs_per(:mw_heat) 0 0
variable_operation_and_maintenance_costs_per(:mw_heat) 0 NaN
total_initial_investment_per(:mw_heat) 0 0
costs_per_mwh_heat
total_costs_per(:mwh_heat) 0 0
fixed_costs_per(:mwh_heat) 0 0
cost_of_capital_per(:mwh_heat) 0 0
depreciation_costs_per(:mwh_heat) 0 0
variable_costs_per(:mwh_heat) 0 NaN
fuel_costs_per(:mwh_heat) 0 NaN
co2_emissions_costs_per(:mwh_heat) 0 NaN
captured_biogenic_co2_costs_per(:mwh_heat) NaN NaN
fixed_operation_and_maintenance_costs_per(:mwh_heat) 0 0
variable_operation_and_maintenance_costs_per(:mwh_heat) 0 NaN
total_initial_investment_per(:mwh_heat) 0 0