Present 341.63 M 341.63 M 341.63 M
Future 341.63 M 341.63 M 341.63 M
Edges 341.63 M Outputs
Node MJ Type
energy_power_hv_network_electricity 334.8 M Flexible
Reversed
98.0 %
2.0 %
Inputs Edges 341.63 M
100.0 %
Type MJ Node
Share 341.63 M environment_water_water
Edges 341.63 M Outputs
Node MJ Type
energy_power_hv_network_electricity 334.8 M Flexible
Reversed
98.0 %
2.0 %
Inputs Edges 341.63 M
100.0 %
Type MJ Node
Share 341.63 M environment_water_water
Method Label Present Future Unit
technical
electricity_output_capacity * number_of_units Installed electrical capacity 36.98 36.98 MW
electricity_output_conversion Electrical efficiency 98.0 98.0 %
full_load_hours Full load hours 2,515 2,515 hour / year
cost
total_investment_over_lifetime_per(:mw_electricity) Investment over lifetime per MW 3600000 3600000 EUR / MW
fixed_operation_and_maintenance_costs_per(:mw_electricity) Fixed operation and maintenance costs 32000 32000 EUR / MW / year
variable_operation_and_maintenance_costs_per_full_load_hour Variable operation and maintenance costs 0 0 EUR / full load hour
wacc Weighted average cost of capital 4.0 4.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? true true boolean
other
technical_lifetime Technical lifetime 45 45 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 10 10 0% MWe
heat_output_capacity 0 0 MWth
hydrogen_output_capacity 0 0 MW
free_co2_factor 0 0
ccs_capture_rate - -
construction_time 2 2 0%
electrical_efficiency_when_using_coal - -
electrical_efficiency_when_using_wood_pellets - -
full_load_hours 2,515 2,515 0%
households_supplied_per_unit - -
land_use_per_unit 0 0
takes_part_in_ets 1 1 0% yes=1 / no=0
technical_lifetime 45 45 0% year
typical_input_capacity - - MWinput
output_capacity - - MW
input_efficiency - -
output_efficiency - -
cost
initial_investment 36 M 36 M 0% euro / unit
ccs_investment 0 0 euro / unit
cost_of_installing 0 0 euro / unit
decommissioning_costs 0 0 euro / unit
fixed_operation_and_maintenance_costs_per_year 320 K 320 K 0% euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 0 0 euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 0 0 euro / full load hour
fixed_costs_per_mw_input_capacity - - euro / MWinput
costs_per_mj - -
wacc 0.04 0.04 0%
profitability - - profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity - - eur/MWh
marginal_costs 0 0 euro / MWh
max_consumption_price 0 0 euro / MWh
merit_order
merit_order_full_load_hours - -
merit_order_capacity_factor - -
merit_order_position - -
security_of_supply
availability 0.98 0.98 0%
part_load_operating_point 0.7 0.7 0%
part_load_efficiency_penalty 0.1 0.1 0%
forecasting_error 0 0
misc
demand_expected_value - -
excel_id - -
max_demand - -
Node Calculations Present Future Change Unit
demand
demand 341.63 M 341.63 M 0%
preset_demand 341.63 M 341.63 M 0%
demand_of_sustainable 0 0
weighted_carrier_cost_per_mj 0 0
weighted_carrier_co2_per_mj 0 0
sustainability_share 1 1 0%
final_demand 0 0
primary_demand 334.8 M 334.8 M 0%
primary_demand_of_fossil 0 0
primary_demand_of_sustainable 334.8 M 334.8 M 0%
primary_demand_of_electricity 334.8 M 334.8 M 0%
technical
input_capacity 10.2 10.2 0%
electric_based_input_capacity 10.2 10.2 0% MWinput
heat_based_input_capacity - - MWinput
cooling_based_input_capacity - - MWinput
number_of_units 3.7 3.7 0%
costs_per_plant
total_costs_per(:plant) 1,872 K 1,872 K 0% euro / plant
fixed_costs_per(:plant) 1,872 K 1,872 K 0%
cost_of_capital_per(:plant) 752 K 752 K 0%
depreciation_costs_per(:plant) 800 K 800 K 0%
variable_costs_per(:plant) 0 0
fuel_costs_per(:plant) 0 0
co2_emissions_costs_per(:plant) 0 0
captured_biogenic_co2_costs_per(:plant) 0 0
fixed_operation_and_maintenance_costs_per(:plant) 320 K 320 K 0%
variable_operation_and_maintenance_costs_per(:plant) 0 0
total_initial_investment_per(:plant) 36 M 36 M 0%
costs_per_node
total_costs_per(:node) 6,922 K 6,922 K 0%
fixed_costs_per(:node) 6,922 K 6,922 K 0%
cost_of_capital_per(:node) 2,781 K 2,781 K 0%
depreciation_costs_per(:node) 2,958 K 2,958 K 0%
variable_costs_per(:node) 0 0
fuel_costs_per(:node) 0 0
co2_emissions_costs_per(:node) 0 0
captured_biogenic_co2_costs_per(:node) 0 0
fixed_operation_and_maintenance_costs_per(:node) 1,183 K 1,183 K 0%
variable_operation_and_maintenance_costs_per(:node) 0 0
total_initial_investment_per(:node) 133.12 M 133.12 M 0%
costs_per_mw_electricity
total_costs_per(:mw_electricity) 187 K 187 K 0%
fixed_costs_per(:mw_electricity) 187 K 187 K 0%
cost_of_capital_per(:mw_electricity) 75,200 75,200 0%
depreciation_costs_per(:mw_electricity) 80,000 80,000 0%
variable_costs_per(:mw_electricity) 0 0
fuel_costs_per(:mw_electricity) 0 0
co2_emissions_costs_per(:mw_electricity) 0 0
captured_biogenic_co2_costs_per(:mw_electricity) 0 0
fixed_operation_and_maintenance_costs_per(:mw_electricity) 32,000 32,000 0%
variable_operation_and_maintenance_costs_per(:mw_electricity) 0 0
total_initial_investment_per(:mw_electricity) 3,600 K 3,600 K 0%
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 74.43 74.43 0%
fixed_costs_per(:mwh_electricity) 74.43 74.43 0%
cost_of_capital_per(:mwh_electricity) 29.9 29.9 0%
depreciation_costs_per(:mwh_electricity) 31.81 31.81 0%
variable_costs_per(:mwh_electricity) 0 0
fuel_costs_per(:mwh_electricity) 0 0
co2_emissions_costs_per(:mwh_electricity) 0 0
captured_biogenic_co2_costs_per(:mwh_electricity) 0 0
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 12.72 12.72 0%
variable_operation_and_maintenance_costs_per(:mwh_electricity) 0 0
total_initial_investment_per(:mwh_electricity) 1,431.4 1,431.4 0%
costs_per_mw_heat
total_costs_per(:mw_heat) 0 0
fixed_costs_per(:mw_heat) 0 0
cost_of_capital_per(:mw_heat) 0 0
depreciation_costs_per(:mw_heat) 0 0
variable_costs_per(:mw_heat) NaN NaN
fuel_costs_per(:mw_heat) NaN NaN
co2_emissions_costs_per(:mw_heat) NaN NaN
captured_biogenic_co2_costs_per(:mw_heat) NaN NaN
fixed_operation_and_maintenance_costs_per(:mw_heat) 0 0
variable_operation_and_maintenance_costs_per(:mw_heat) NaN NaN
total_initial_investment_per(:mw_heat) 0 0
costs_per_mwh_heat
total_costs_per(:mwh_heat) 0 0
fixed_costs_per(:mwh_heat) 0 0
cost_of_capital_per(:mwh_heat) 0 0
depreciation_costs_per(:mwh_heat) 0 0
variable_costs_per(:mwh_heat) NaN NaN
fuel_costs_per(:mwh_heat) NaN NaN
co2_emissions_costs_per(:mwh_heat) NaN NaN
captured_biogenic_co2_costs_per(:mwh_heat) NaN NaN
fixed_operation_and_maintenance_costs_per(:mwh_heat) 0 0
variable_operation_and_maintenance_costs_per(:mwh_heat) NaN NaN
total_initial_investment_per(:mwh_heat) 0 0