Present 0 0 0
Future 0 0 0
Edges 0 Outputs
Node MJ Type
energy_power_hv_network_electricity 0 Flexible
Reversed
30.5 %
69.5 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_distribution_lignite
0.0 %
Type MJ Node
Share 0 energy_distribution_torrefied_biomass_pellets
Edges 0 Outputs
Node MJ Type
energy_power_hv_network_electricity 0 Flexible
Reversed
30.5 %
69.5 %
Inputs Edges 0
100.0 %
Type MJ Node
Share 0 energy_distribution_lignite
0.0 %
Type MJ Node
Share 0 energy_distribution_torrefied_biomass_pellets

Details

Sector energy
Use undefined
Merit Order
level
hv
subtype
dispatchable
type
producer
Node groups
  1. preset_demand
  2. central_production
  3. electricity_production
  4. ccs_technology_pair
  5. dispatchable_production
  6. hv_net_supply
  7. wacc_proven_tech
  8. costs_production_power_plants
  9. sankey_conversion_group
Used in Gqueries
  1. costs_of_coal_oxyfuel_ccs_in_overview_costs_of_electricity_production
  2. energy_power_ultra_supercritical_oxyfuel_ccs_lignite
  3. energy_power_ultra_supercritical_oxyfuel_ccs_lignite_delta_in_investment_cost_table
  4. energy_power_ultra_supercritical_oxyfuel_ccs_lignite_future_in_investment_cost_table
  5. energy_power_ultra_supercritical_oxyfuel_ccs_lignite_present_in_investment_cost_table
  6. investment_for_coal_oxyfuel_ccs_in_overview_costs_of_electricity_production
  7. merit_order_lignite_oxy_availability_in_merit_order_table
  8. merit_order_lignite_oxy_capacity_in_merit_order_table
  9. merit_order_lignite_oxy_full_load_hours_in_merit_order_table
  10. merit_order_lignite_oxy_load_factor_in_merit_order_table
  11. merit_order_lignite_oxy_operating_costs_in_merit_order_table
  12. merit_order_lignite_oxy_position_in_merit_order_table
  13. total_cost_of_energy_power_ultra_supercritical_oxyfuel_ccs_lignite
  14. turk_energy_power_ultra_supercritical_oxyfuel_ccs_lignite_capture_rate
Used in Inputs
  1. capacity_of_energy_power_ultra_supercritical_lignite
  2. co_firing_biocoal_share
  3. co_firing_coal_share
  4. investment_costs_co2_ccs
  5. investment_costs_combustion_coal_plant
  6. om_costs_co2_ccs
  7. om_costs_combustion_coal_plant
  8. share_of_energy_power_ultra_supercritical_oxyfuel_ccs_lignite
Method Label Present Future Unit
technical
electricity_output_capacity * number_of_units Installed electrical capacity 0 0 MW
electricity_output_conversion Electrical efficiency 30.5 30.5 %
full_load_hours Full load hours 5,972 0 hour / year
cost
initial_investment_per(:mw_electricity) + cost_of_installing_per(:mw_electricity) + decommissioning_costs_per(:mw_electricity) Investment over lifetime per MW 1818181 1818181 EUR / MW
ccs_investment_per(:mw_electricity) Additional initial investment for CCS 1861818 1861818 EUR / MW
fixed_operation_and_maintenance_costs_per(:mw_electricity) Fixed operation and maintenance costs 33191 33191 EUR / MW / year
variable_operation_and_maintenance_costs_per_full_load_hour Variable operation and maintenance costs (excl CCS) 2406 2406 EUR / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour Additional variable operation and maintenance costs for CCS 1681 1681 EUR / full load hour
wacc Weighted average cost of capital 7.0 7.0 %
takes_part_in_ets Do emissions have to be paid through the ETS? true true boolean
other
technical_lifetime Technical lifetime 30 30 years
Node Attributes Present Future Change Unit
operational
electricity_output_capacity 660 660 0% MWe
heat_output_capacity 0 0 MWth
hydrogen_output_capacity 0 0 MW
free_co2_factor 0.85 0.85 0%
ccs_capture_rate 0.85 0.85 0%
construction_time 4 4 0%
electrical_efficiency_when_using_coal - -
electrical_efficiency_when_using_wood_pellets - -
full_load_hours 5,972 0 -100%
households_supplied_per_unit - -
land_use_per_unit 0.4 0.4 0%
takes_part_in_ets 1 1 0% yes=1 / no=0
technical_lifetime 30 30 0% year
typical_input_capacity - - MWinput
output_capacity - - MW
input_efficiency - -
output_efficiency - -
cost
initial_investment 1.2 B 1.2 B 0% euro / unit
ccs_investment 1.23 B 1.23 B 0% euro / unit
cost_of_installing 0 0 euro / unit
decommissioning_costs 0 0 euro / unit
fixed_operation_and_maintenance_costs_per_year 21.91 M 21.91 M 0% euro / unit / year
variable_operation_and_maintenance_costs_per_full_load_hour 2,406.4 2,406.4 0% euro / full load hour
variable_operation_and_maintenance_costs_for_ccs_per_full_load_hour 1,681.7 1,681.7 0% euro / full load hour
fixed_costs_per_mw_input_capacity - - euro / MWinput
costs_per_mj - -
wacc 0.07 0.07 0%
profitability - profitable / unprofitable / conditionally_profitable
profit_per_mwh_electricity - - eur/MWh
marginal_costs 19.39 19.39 0% euro / MWh
max_consumption_price 19.39 19.39 0% euro / MWh
merit_order
merit_order_full_load_hours - -
merit_order_capacity_factor - -
merit_order_position - -
security_of_supply
availability 0.87 0.87 0%
part_load_operating_point 0.7 0.7 0%
part_load_efficiency_penalty 0.1 0.1 0%
forecasting_error 0 0
misc
demand_expected_value - -
excel_id - -
max_demand - -
Node Calculations Present Future Change Unit
demand
demand 0 0
preset_demand 0 0
demand_of_sustainable 0 0
weighted_carrier_cost_per_mj 0.001 0.001 0%
weighted_carrier_co2_per_mj 0.101 0.101 0%
sustainability_share 0 0
final_demand 0 0
primary_demand 0 0
primary_demand_of_fossil 0 0
primary_demand_of_sustainable 0 0
technical
input_capacity 2,163.9 2,163.9 0%
electric_based_input_capacity 2,163.9 2,163.9 0% MWinput
heat_based_input_capacity - - MWinput
cooling_based_input_capacity - - MWinput
number_of_units 0 0
costs_per_plant
total_costs_per(:plant) 275.62 M 199.21 M -27% euro / plant
fixed_costs_per(:plant) 199.21 M 199.21 M 0%
cost_of_capital_per(:plant) 96.34 M 96.34 M 0%
depreciation_costs_per(:plant) 80.96 M 80.96 M 0%
variable_costs_per(:plant) 76.42 M 0 -100%
fuel_costs_per(:plant) 51.18 M 0 -100%
co2_emissions_costs_per(:plant) 826 K 0 -100%
captured_biogenic_co2_costs_per(:plant) 0 0
fixed_operation_and_maintenance_costs_per(:plant) 21.91 M 21.91 M 0%
variable_operation_and_maintenance_costs_per(:plant) 24.41 M 0 -100%
total_initial_investment_per(:plant) 2.43 B 2.43 B 0%
costs_per_node
total_costs_per(:node) 0 0
fixed_costs_per(:node) 0 0
cost_of_capital_per(:node) 0 0
depreciation_costs_per(:node) 0 0
variable_costs_per(:node) 0 0
fuel_costs_per(:node) 0 0
co2_emissions_costs_per(:node) 0 0
captured_biogenic_co2_costs_per(:node) 0 0
fixed_operation_and_maintenance_costs_per(:node) 0 0
variable_operation_and_maintenance_costs_per(:node) 0 0
total_initial_investment_per(:node) 0 0
costs_per_mw_electricity
total_costs_per(:mw_electricity) 418 K 302 K -27%
fixed_costs_per(:mw_electricity) 302 K 302 K 0%
cost_of_capital_per(:mw_electricity) 146 K 146 K 0%
depreciation_costs_per(:mw_electricity) 123 K 123 K 0%
variable_costs_per(:mw_electricity) 116 K 0 -100%
fuel_costs_per(:mw_electricity) 77,538.1 0 -100%
co2_emissions_costs_per(:mw_electricity) 1,251.9 0 -100%
captured_biogenic_co2_costs_per(:mw_electricity) 0 0
fixed_operation_and_maintenance_costs_per(:mw_electricity) 33,191.2 33,191.2 0%
variable_operation_and_maintenance_costs_per(:mw_electricity) 36,990.8 0 -100%
total_initial_investment_per(:mw_electricity) 3,680 K 3,680 K 0%
costs_per_mwh_electricity
total_costs_per(:mwh_electricity) 69.93 0 -100%
fixed_costs_per(:mwh_electricity) 50.54 0 -100%
cost_of_capital_per(:mwh_electricity) 24.44 0 -100%
depreciation_costs_per(:mwh_electricity) 20.54 0 -100%
variable_costs_per(:mwh_electricity) 19.39 NaN
fuel_costs_per(:mwh_electricity) 12.98 NaN
co2_emissions_costs_per(:mwh_electricity) 0.21 NaN
captured_biogenic_co2_costs_per(:mwh_electricity) 0 NaN
fixed_operation_and_maintenance_costs_per(:mwh_electricity) 5.56 0 -100%
variable_operation_and_maintenance_costs_per(:mwh_electricity) 6.19 NaN
total_initial_investment_per(:mwh_electricity) 616.2 0 -100%
costs_per_mw_heat
total_costs_per(:mw_heat) 0 0
fixed_costs_per(:mw_heat) 0 0
cost_of_capital_per(:mw_heat) 0 0
depreciation_costs_per(:mw_heat) 0 0
variable_costs_per(:mw_heat) 0 NaN
fuel_costs_per(:mw_heat) 0 NaN
co2_emissions_costs_per(:mw_heat) 0 NaN
captured_biogenic_co2_costs_per(:mw_heat) NaN NaN
fixed_operation_and_maintenance_costs_per(:mw_heat) 0 0
variable_operation_and_maintenance_costs_per(:mw_heat) 0 NaN
total_initial_investment_per(:mw_heat) 0 0
costs_per_mwh_heat
total_costs_per(:mwh_heat) 0 0
fixed_costs_per(:mwh_heat) 0 0
cost_of_capital_per(:mwh_heat) 0 0
depreciation_costs_per(:mwh_heat) 0 0
variable_costs_per(:mwh_heat) 0 NaN
fuel_costs_per(:mwh_heat) 0 NaN
co2_emissions_costs_per(:mwh_heat) 0 NaN
captured_biogenic_co2_costs_per(:mwh_heat) NaN NaN
fixed_operation_and_maintenance_costs_per(:mwh_heat) 0 0
variable_operation_and_maintenance_costs_per(:mwh_heat) 0 NaN
total_initial_investment_per(:mwh_heat) 0 0